WL250
Operating,
Installation,
and
Service
Manual
Page
53
‐
Revision:
4
‐
25
‐
2016
Steady
Drip
Out
of
Faucet
Possible
Reason
Solution
Debris
in
Solenoid
Inspect
Solenoid
for
debris
and
clean
out
as
needed.
Hot
Water
or
Steam
Coming
out
of
both
the
Faucet
and
Vent
Hole
Possible
Reason
Solution
Improper
tubing
attachment
from
the
hot
tank
to
faucet
or
vice
versa.
Check
that
the
tubing
is
connected
from
tank
outlets
to
correct
faucet
attachments.
Connect
tubing
to
outlets
as
needed.
Hot
Water
Coming
out
of
Faucet
Vent
Hole
Possible
Reason
Solution
Improper
tubing
attachment
from
the
tank
to
faucet
or
vice
versa.
Verify
tubing
is
connected
properly
from
tank
outlets
to
correct
faucet
attachments.
Hot
Tank
outlet
hole
is
scaled
over.
Inspect
and
Descale
Tank
as
needed.
See
Hot
Tank
Descaling
Instructions
that
are
included
further
below
in
this
Troubleshooting
Section.
See
instructional
video
on
the
Partner
Area
of
the
Waterlogic.com
website
for
more
information.
Expansion
chamber
is
not
sealed
properly.
Replace
the
Hot
Tank.