HOT
WATER
TROUBLESHOOTING
INDEX
Hot Water Problems
1. Hot Water is not Hot 185° +/- 5°
Also includes related instructions for Resetting the Hot Tank Overload or High Limit
Safety
Hot
Water
is
not
Hot
(185
°
+/
‐
5
°
F)
NOTE:
The
WL250
Water
Treatment
System
does
NOT
have
Sleep
or
Power
Saving
Mode
and
the
hot
water
should
be
a
minimum
of
185
°
F
under
normal
operating
conditions.
The
Hot
temperature
set
point
is
185
°
F
and
is
controlled
by
a
thermostat
on
the
side
of
the
tank.
There
is
a
resettable
overload
or
high
limit
safety
above
the
thermostat
on
the
side
of
the
tank
that
will
trip
to
prevent
damage
to
the
unit
if
the
tank
is
dry
heated
(turned
on
without
water
in
it).
The
WL250
does
NOT
have
Extra
Hot
capability
and
the
maximum
hot
temperature
is
189
°
F.
It
typically
takes
10
minutes
for
the
500W
to
heat
the
1.6
Liter
of
room
temperature
(ambient)
water
to
the
185
°
F
set
point.
Possible
Reason
Solution
No
power
to
heater
elements
Check
that
the
Red
Heater
and
Compressor
switch
is
on.
Turn
Red
Heater
and
Compressor
Switch
on.
I
=
ON
Hot
Tank
Overload
Tripped
Overload
is
a
safety
feature
to
ensure
the
tank
does
not
overheat.
Overload
will
“click”
when
pushed.
The
overload
is
automatically
reset
when
pressed.
See
Resetting
the
Hot
Tank
Overload
or
High
Limit
Safety
Instructions
that
are
included
further
below
in
this
Troubleshooting
Section
Thermostat
or
overload
“open”
on
Hot
Tank
Turn
Power
off.
Check
OHM’s
resistance
across
terminals
on
each
Thermostat
and
Overload
separately.
Good
components
will
indicate
a
closed
circuit
or
zero
OHM’s
on
the
meter.
Replace
components
as
necessary.