WL250

 Manual 

                                                      Page 54 ‐ Revision: 12‐12‐2018 

2.

 

Red Power Switch is lit but the Red LED on the Front is not lit  

Possible Reason 

Solution 

Bad Transformer 

Replace Transformer 

Black Power Connector to the 
PCB is not properly connected 

Properly connect. 

Bad Front PCB  

Replace Front PCB 
Hot and Cold – P/N EN‐6085 WLCP PN 12‐8103 
Cold Only – P/N EN‐6086 WLCP PN 12‐8615 

Defective Red Heater / 
Compressor Switch 

Replace Red Heater / Compressor Switch 

 

 

3.

 

Compressor Runs but Does Not Chill 

Possible Reason 

Solution 

Condenser is dirty 

Clean the condensing coil of any obstructions or dust. 

Reduction of airflow into unit. 

Make sure unit is not under minimum ventilation requirements (2 
to 4 inches). 

Compressor is running very 
hot. 

Low or lost refrigerant.  Refrigerant recharge required. 

 

4.

 

Compressor is Not Running 

Possible Reason 

Solution 

Red Heater and Compressor 
Switch button on unit is in the 
off position 

 
 
Turn Red Heater and Compressor Switch on.   

I = ON

 

 

Compressor Starting Circuit 

Turn Red Heater and Compressor Switch off.  

O = OFF. 

 
Remove the compressor cap on side of the compressor;   
 
Disconnect the black and red terminal connectors;  
 
Inspect the starter and overload relay for any defects.   
 
Replace components(s) as needed. 
 
Turn Red Heater and Compressor Switch on 

I = ON 

and retest 

compressor operation. 