Good components will indicate a closed circuit or zero
OHM’s on the meter.
Replace components as necessary.
Heating Coil Not Working
Turn Power off; Drain hot tank; Use multi-meter to check
heater element for approximately 26 OHM’s resistance.
Hot Tank must be empty if you are checking for continuity.
Replace Hot Tank as necessary.
Loose or improperly
connected wire(s) to the
Heating Element / Hot Tank.
Visually inspect wire leads gong to the hot tank; confirm
proper connections to the heating elements.
Hot tank life is 3-5 years, depending on usage.
*Typically, dealers swap out the Hot Tank at site, take back
to the shop to repair.