INSTALLATION INSTRUCTIONS

Bottom Drain Models #2901, #2902 and #2903

For additional installation instructions that pertain to each individual urinal, please see next page.

BOX CONTENTS:

                                                   

2-

EcoTrap

® Inserts; 2-Wall Hangers; 

1-Tile Label; 2-Washers; 4-Plastic Anchors; 4-Screws; 

TOOLS/HARDWARE NEEDED:

Screwdriver; 5/16” (7.9mm) Masonry Drill Bit and Drill; Putty 

Knife; Water Supply Cap (for retrofit only); Caulk; 2-Screws

BEFORE YOU BEGIN:

• 

Do not

 install 

No-Flush

™ urinals without prior waste

  line clean out. 

Do not

 double trap 

No-Flush

™ urinal.

•   Please insure that the new urinal has the correct 

  rough-in dimensions.

•  When working with highly polished plastic or ceramic

  products, please use care in handling the unit

  during installation to avoid scratches or chip marks.

•   Over-tightening bolts and screws may result 

  in damage to the urinal.

•   Measure drain line height for correct urinal height. 

TO REMOVE EXISTING URINAL:

Turn off the water supply. Flush the urinal to drain valve and 

scoop or sponge out remaining water in urinal. Disconnect the 

flushometer valve completely and cap water supply line at tile. 

Remove urinal shell from wall and clean off any residues from 

wall and flange.

BEFORE YOU INSTALL URINAL:

Do not

 install 

No-Flush

™ urinal without prior waste line clean 

out. Existing scaling and debris in the waste line will inhibit the 

flow of waste from Waterless™ urinal and its proper functioning 

can not be guaranteed. 

No-Flush

™ urinals are engineered, how-

ever, to reduce waste line scaling.

TO INSTALL NO-FLUSH™ URINAL:

• 

Waterless urinal should be attached to wall so that urinal lip

  is 24” off floor (for ADA urinal 17” lip to floor).  

• 

Measure required instruction sheet height per urinal above

  center of waste line/rough-in.

#2902 DEL CASA & #2903 SANTA FE Installation Instructions

• 

Mark holes for wall hangers at desired height and 5.5” (127mm)

  for #2902 and 4.0” (102mm) for #2903 to each side of urinal

  center. Assure hangers are aligned horizontally. Drill hanger

  holes with 5/16 “ (8mm) drill bit. Attach wall hangers with

  supplied screws and plastic anchors. Tighten screws. 

• 

Mark holes on wall through holes in horizontal bottom

  piece of urinal. Remove urinal and use same drill bit

  to drill holes. Reattach urinal over hangers and screw in

  bottom screws. 

• 

Assemble 2” drain parts (not supplied) as needed.

• 

Lip to floor height to be 24” (610mm) or ADA 17” (432mm)

 

#2901 DEL MAR Installation Instructions

• 

Mark holes for wall/bukhead bolts (not supplied) on

  top of urinal at desired height. Assure holes are aligned

  horizontally. Drill holes with 5/16 “ (8mm) drill bit. 

• 

Mark holes on wall through holes in horizontal bottom

  piece of urinal. Remove urinal and use same drill bit to drill

  holes. Set urinal to wall/bulkhead and hand tighten top of

  urinal with bolts. Attach supplied screws and plastic anchors

  through bottom holes. Tighten screws. 

• 

Assemble 2” drain parts (not supplied) as needed.

• 

Lip to floor height to be 24” (610mm) or ADA 17” (432mm)

FOR ALL THREE: #2901, #2902 & #2903

  Measure 2” drain parts, in accordance with local trade

  practices, for connection from urinal to drain line. 

  Trial assemble all parts to see that all fits. Hand tighten

  pieces. DO NOT DOUBLE TRAP WATERLESS URINAL. The

  urinal has its own integral trap.

•  Caulk around the urinal. Attach enclosed tile label above

  urinal on wall.

INITIAL START-UP:

Wipe urinal clean with soft moist rag. Take enclosed 

EcoTrap

® 

plastic trap insert and set trap into trapway. 

Push trap down 

below rim of trapway. 

Fill with water under faucet in sink. 

Fill until full or water overflows

 

on bottom then add 3 oz. of 

BlueSeal

® liquid. 

Done!

NOTE: 

No flushometer needed for fixture, provide suitable reinforcements for all wall supports and carriers. ADA: Requires urinal rim to 

be mounted 17” above finished floor. Dimensions for fixtures are nominal and may vary within the range of tolerances established 

by ANSI Standard A112.19.2, A112.19.19 and ANSI Z124.9. Measurements are subject to change or cancellation. No responsibility 

is assumed.  For copper DWV drain lines ascertain and document that the installed lines are not corroded or show “channeling”.

Please leave this Installation/Care sheet with the owner/user as it contains important information.

© Waterless Co. Inc. 0118

Содержание Del Mar 2901

Страница 1: ...less Co reserves the right to change product specifications at any time without notice It is the responsibility of the specifier installer and wholesale seller to confirm specification at time of sale...

Страница 2: ...l hangers with supplied screws and plastic anchors Tighten screws Mark holes on wall through holes in horizontal bottom piece of urinal Remove urinal and use same drill bit to drill holes Reattach uri...

Страница 3: ...5 356MM 14 0 25MM 1 0 356MM 14 0 495MM 19 5 381MM 15 0 50MM 2 0 102MM 4 0 102MM 4 0 updat ed 10 03 2011 610 MM 24 0 TO FLOOR ADA 432 MM 17 0 TO FLOOR FOR STANDARD INSTALLATION Mount at 24 above finish...

Страница 4: ...ons 2 The drain line is plugged Remove the EcoTrap and snake the drainline 3 The system is double trapped Remove the drain line trap so that only the EcoTrap is the trap for the system EcoTrap Princip...

Страница 5: ...surfaces for cleaning 3 Use cleaner on wet sponge cloth or mop Then wipe clean all surfaces of urinal especially the lower front 4 Dry all surfaces with a soft cloth or soft rag Cleaning Instructions...

Страница 6: ...and remove X Traptor 6 Seal the plastic bag and discard in locally appropriate manner 7 Loosen any sediment accumulation in drain hole with any long object 8 Pour a full bucket approx 5 gallons of pr...

Страница 7: ...accidents acts of God misuse unauthorized repairs negligence modifications tampering disconnection improper adjustments improper care or maintenance im proper installation and out of warranty service...

Страница 8: ...__________ Fax ____ ______________E Mail ______________________Purchased From __________________________ Model 2003__2004___2005___2104___2902___2903___Other_____________Purchase Date _________ Instal...