INSTALLATION INSTRUCTIONS
Bottom Drain Models #2901, #2902 and #2903
For additional installation instructions that pertain to each individual urinal, please see next page.
BOX CONTENTS:
2-
EcoTrap
® Inserts; 2-Wall Hangers;
1-Tile Label; 2-Washers; 4-Plastic Anchors; 4-Screws;
TOOLS/HARDWARE NEEDED:
Screwdriver; 5/16” (7.9mm) Masonry Drill Bit and Drill; Putty
Knife; Water Supply Cap (for retrofit only); Caulk; 2-Screws
BEFORE YOU BEGIN:
•
Do not
install
No-Flush
™ urinals without prior waste
line clean out.
Do not
double trap
No-Flush
™ urinal.
• Please insure that the new urinal has the correct
rough-in dimensions.
• When working with highly polished plastic or ceramic
products, please use care in handling the unit
during installation to avoid scratches or chip marks.
• Over-tightening bolts and screws may result
in damage to the urinal.
• Measure drain line height for correct urinal height.
TO REMOVE EXISTING URINAL:
Turn off the water supply. Flush the urinal to drain valve and
scoop or sponge out remaining water in urinal. Disconnect the
flushometer valve completely and cap water supply line at tile.
Remove urinal shell from wall and clean off any residues from
wall and flange.
BEFORE YOU INSTALL URINAL:
Do not
install
No-Flush
™ urinal without prior waste line clean
out. Existing scaling and debris in the waste line will inhibit the
flow of waste from Waterless™ urinal and its proper functioning
can not be guaranteed.
No-Flush
™ urinals are engineered, how-
ever, to reduce waste line scaling.
TO INSTALL NO-FLUSH™ URINAL:
•
Waterless urinal should be attached to wall so that urinal lip
is 24” off floor (for ADA urinal 17” lip to floor).
•
Measure required instruction sheet height per urinal above
center of waste line/rough-in.
#2902 DEL CASA & #2903 SANTA FE Installation Instructions
•
Mark holes for wall hangers at desired height and 5.5” (127mm)
for #2902 and 4.0” (102mm) for #2903 to each side of urinal
center. Assure hangers are aligned horizontally. Drill hanger
holes with 5/16 “ (8mm) drill bit. Attach wall hangers with
supplied screws and plastic anchors. Tighten screws.
•
Mark holes on wall through holes in horizontal bottom
piece of urinal. Remove urinal and use same drill bit
to drill holes. Reattach urinal over hangers and screw in
bottom screws.
•
Assemble 2” drain parts (not supplied) as needed.
•
Lip to floor height to be 24” (610mm) or ADA 17” (432mm)
#2901 DEL MAR Installation Instructions
•
Mark holes for wall/bukhead bolts (not supplied) on
top of urinal at desired height. Assure holes are aligned
horizontally. Drill holes with 5/16 “ (8mm) drill bit.
•
Mark holes on wall through holes in horizontal bottom
piece of urinal. Remove urinal and use same drill bit to drill
holes. Set urinal to wall/bulkhead and hand tighten top of
urinal with bolts. Attach supplied screws and plastic anchors
through bottom holes. Tighten screws.
•
Assemble 2” drain parts (not supplied) as needed.
•
Lip to floor height to be 24” (610mm) or ADA 17” (432mm)
FOR ALL THREE: #2901, #2902 & #2903
•
Measure 2” drain parts, in accordance with local trade
practices, for connection from urinal to drain line.
•
Trial assemble all parts to see that all fits. Hand tighten
pieces. DO NOT DOUBLE TRAP WATERLESS URINAL. The
urinal has its own integral trap.
• Caulk around the urinal. Attach enclosed tile label above
urinal on wall.
INITIAL START-UP:
Wipe urinal clean with soft moist rag. Take enclosed
EcoTrap
®
plastic trap insert and set trap into trapway.
Push trap down
below rim of trapway.
Fill with water under faucet in sink.
Fill until full or water overflows
on bottom then add 3 oz. of
BlueSeal
® liquid.
Done!
NOTE:
No flushometer needed for fixture, provide suitable reinforcements for all wall supports and carriers. ADA: Requires urinal rim to
be mounted 17” above finished floor. Dimensions for fixtures are nominal and may vary within the range of tolerances established
by ANSI Standard A112.19.2, A112.19.19 and ANSI Z124.9. Measurements are subject to change or cancellation. No responsibility
is assumed. For copper DWV drain lines ascertain and document that the installed lines are not corroded or show “channeling”.
Please leave this Installation/Care sheet with the owner/user as it contains important information.
© Waterless Co. Inc. 0118