Risk of burns!
During operation, surface temperatures (compressor and pressure line) can
climb above 100 °C or drop below 0 °C.
Do not remove housing cover during operation!
Allow heat pump to cool down before removing cover.
Risk of injury!
Risk of chemical burns: when skin has a direct contact with lubricant leak.
Wear suitable clothing when performing maintenance work on the heat
pump!
Risk of injury in case of leakage in cooling circuit!
Skin contact with refrigerant may cause freezing of tissue and frostbites.
High vapour concentrations can cause headaches, dizziness, fatigue, nau-
sea and even unconsciousness. Irregular heartbeat (arrhythmia).
Avoid contact with refrigerant! Do not expose to heat, sparks, naked light or
other ignition sources!
Electrostatic charge!
Electronic components can be damaged by electrostatic processes.
Ground yourself before touching electronic components.
Risk of total loss!
Repeated restart of heat pump can result in total loss!
In case of heat pump failure, before restart an inspection by qualified
and authorised personnel must be performed.
Due to test bench operation, the heat pump can have ethylene glycol resi-
dues.