16
Copyright © 2021, Waterite, Inc. All Rights Reserved
General System Specifications
RSL
RSLHP
Model
2400
4800
7200
9600
2400
4800
7200
9600
Basic System Specifications
Nominal Capacity
(GPD)
2400
4800
7200
9600
2400
4800
7200
9600
System
Dimensions WxDxH
31"x24"x50" 31"x24"x50" 31"x24"x50" 31"x24"x50" 31"x24"x50" 31"x24"x50" 31"x24"x50" 31"x24"x50"
System Weight (LBS)
Dry / Full
96 / 124
114 / 142
132 / 160
154 / 178
96 / 124
114 / 142
132 / 160
154 / 178
Plumbing Connection Specifications
Inlet Line Size
1" FPT
1" FPT
1" FPT
1" FPT
1" FPT
1" FPT
1" FPT
1" FPT
Reject Line Size
1/2" Push
1/2" FPT
3/4" FPT
1/2" Push
1/2" FPT
3/4" FPT
1/2" Push
1/2" FPT
3/4" FPT
1/2" Push
1/2" FPT
3/4" FPT
1/2" Push
1/2" FPT
3/4" FPT
1/2" Push
1/2" FPT
3/4" FPT
1/2" Push
1/2" FPT
3/4" FPT
1/2" Push
1/2" FPT
3/4" FPT
Product Line Size
1/2" Push
1/2" FPT
1/2" Push
1/2" FPT
1/2" Push
1/2" FPT
1/2" Push
1/2" FPT
1/2" Push
1/2" FPT
1/2" Push
1/2" FPT
1/2" Push
1/2" FPT
1/2" Push
1/2" FPT
Electrical Requirements
Motor HP
3/4 HP
3/4 HP
1 1/2HP
1 1/2HP
2 HP
2 HP
2 HP
2 HP
Motor Electrical
Requirements
230/208V
230/208V
230/208V
230/208V
230/208V
230/208V
230/208V
230/208V
6.4/7.1A
6.4/7.1A
10.3/11.3A 10.3/11.3A 10.3/11.3A 10.3/11.3A 10.3/11.3A 10.3/11.3A
120V Option
(Canada only)
Yes
Yes
No
No
No
No
No
No
Operational Specifications
Operating Pressure
130 PSI
130 PSI
130 PSI
130 PSI
220 PSI
220 PSI
220 PSI
220 PSI
Maximum Pressure
150 PSI
150 PSI
150 PSI
150 PSI
250 PSI
250 PSI
250 PSI
250 PSI
Minimum Feed
Pressure
30 PSI
30 PSI
30 PSI
30 PSI
30 PSI
30 PSI
30 PSI
30 PSI
Feed Pressure Range
30-60 PSI
30-60 PSI
30-60 PSI
30-60 PSI
30-60 PSI
30-60 PSI
30-60 PSI
30-60 PSI
Feed Water Flow Rate
4 USGPM
8 USGPM 12 USGPM 16 USGPM 3.1 USGPM 6.2 USGPM 9.3 USGPM
12.4
USGPM
Feed Flow for Flush
10 USGPM 10 USGPM 10 USGPM 10 USGPM 10 USGPM 10 USGPM 10 USGPM 10 USGPM
Membrane and Filter Specifications
Number of Membranes
1
2
3
4
1
2
3
4
Membrane Size
4" x 40"
4" x 40"
4" x 40"
4" x 40"
4" x 40"
4" x 40"
4" x 40"
4" x 40"
Pre-Filter Size
5" x 20"
5" x 20"
5" x 20"
5" x 20"
5" x 20"
5" x 20"
5" x 20"
5" x 20"
!
INSTALLATIONS WITH 208V SERVICE MAY REQUIRE THE USE OF A BOOST TRANSFORMER TO ENSURE A
CONSTANT 208V TO THE SOLENOID VALVES. VARIABILITY IN 208V SERVICE CAN CAUSE VOLTAGE TO DROP
BELOW THE VALVE REQUIREMENTS.