background image

7

 

 

START UP INSTRUCTIONS

 

• After installation is completed and checked for leaks, rotate the bypass handles to the bypass position 

(see Figure 2, Bypass Valve diagram page in main manual).

 

 

• Fully open a cold water faucet.

 

 

• Allow water to run until clear to rid pipes of debris, which may have occurred during installation.

 

 

• The system is now ready for testing:

 

 

1. For all units...

With the bypass valve still in the bypass mode.

 

If starting up a softener or a regenerating filter, manually pour enough water into the regenerant 

tank to reach the top of the air check valve.

 

 

2. 

Press and hold the UP and DOWN buttons simultaneously for three seconds until the drive 

motor starts. Wait until the motor stops and the display reads “C1”, 1st backwash position.

 

 

3. 

Open the inlet  handle  of  the bypass  valve  very  slightly allowing  water  to fill the tank slowly in 

order to expel air. Go to 4a or 4b.

 

CAUTION: If water flows too rapidly, there will be a loss of media to the drain.

 

 

4a. For softeners and regenerating filters only, Programs PO-P6...

 

• 

When the water is flowing steadily to the drain without the presence of air,  press the UP 

button. This will advance the valve to the regenerant draw position, C2.

 

• 

Fully open the inlet bypass valve handle (the diagnostic mode, Figure 3.)

 

Check to verify that regenerant solution is being drawn from the regenerant tank with no air 

bubbles.

 

There should be a slow flow to the drain.

 

Allow three minutes for the media bed to settle. Go to 4b.

 

 

4b. For all units including backwashing filters and acid neutralizers, Programs P7-P9...

 

• Press the UP button again until the control valve displays cycle C4, final rinse. Depending on 

the program used C3, 2nd backwash, may appear before C4 is displayed. Allow water to run to 

the drain for 2-3 minutes or until clear. At this point the control may be allowed to automatically 

time out and return to service or SET HOUR + DOWN can be pressed to exit program.

 

 

5. For softeners and regenerating filters only, Programs PO-P6...

 

• Press the UP button to advance the control  to where the display reads C5. This will allow 

water to refill the regenerant tank and prepare it for the next regeneration. Allow this to time out 

automatically and return to service.

 

• 

While the regenerant tank is filling, load it with salt or regenerant chemical, if appropriate.

 

Содержание Fusion 2

Страница 1: ...FT WITH THE OWNER OF THE EQUIPMENT FOR REFERENCE PURPOSES AND TECHNICAL GUIDANCE IT IS STRONGLY RECOMMENDED THAT QUALIFIED DEALER SERVICE PERSONNEL BE CONTACTED IN THE EVENT OF AN UNKNOWN INTERRUPTION...

Страница 2: ......

Страница 3: ...ingSETHOURand UP simultaneouslyfor3 seconds 2 Adjusttimeof regenerationhourusing the UP or DOWN An arrow points to PM duringp m hours Simultaneously pressSETHOURandDOWNtoreturn tonormal operation MANU...

Страница 4: ...ption f Note that an external signaling device like a pressure differential switch can be used to trigger the backwashing of a filter An explanation of this is at the end of SYSTEM SETUP g Use the mai...

Страница 5: ...e five minute time out are incorporated To quickly exit SOFTENER SETUP or INSTALLER SETTINGS press SET HOUR and DOWN Any changes made prior to the exit are incorporated SYSTEM SETUP STEP 1SS STEP 2SS...

Страница 6: ...o choices If a differential switch is not installed the settings in this display are ignored Press SET HOUR to exit SYSTEM SETUP NOTE The two terminals at A if connected to an external pressure differ...

Страница 7: ...SET HOUR UP buttons simultaneously for 3 seconds and release Set Regeneration Time STEP 2I7 STEP 3I7 STEP 4I7 STEP 2I7 Regeneration Time Set the clock to the hour the regeneration should occur by usi...

Страница 8: ...ing and an arrow will also point to Regen The system will run through the steps automatically and will reset itself to provide treated water when the regeneration is completed Manual Regeneration Some...

Страница 9: ...g steadily to the drain without the presence of air press the UP button This will advance the valve to the regenerant draw position C2 Fully open the inlet bypass valve handle the diagnostic mode Figu...

Страница 10: ...momentarily unplug power from PC board e Motor not fully inserted and not engaging pinion gear Motor wires loose or broken Motor failure e Checkmotor and wiring Replace motor if necessary f Centerdriv...

Страница 11: ...PAGE LEFT BLANK INTENTIONALLY...

Страница 12: ...WATERITE INC Winnipeg Manitoba Canada www waterite com...

Отзывы: