3
GENERAL INSTRUCTIONS
The control valve offers multiple procedures that allow the valve to be modified to suit the needs of the
installation. These procedures are:
•
SYSTEM SETUP
•
INSTALLER SETTINGS
These procedures can be accessed in any order. Details on each of the procedures are provided on the
following pages.
When in operation,
NORMAL OPERATING DISPLAYS
show the time of day or days remaining before
regeneration. When stepping through a procedure if no buttons are pressed within five minutes the display
returns to a normal user display. Any changes made prior to the five minute time out are incorporated.
To quickly exit
SYSTEM SETUP
or
INSTALLER SETTINGS
simultaneously press SET HOUR + DOWN. Any
changes made prior to the exit are incorporated.
To reinitialize the control valve (usually needed after disassembly), check to be sure the valve is in the
NORMAL
OPERATING DISPLAYS
. Then simultaneously press SET HOUR + DOWN or unplug power source plug (black
wire) on the circuit board, and plug back in. When stepping through the displays, if no buttons are pressed within
five minutes, the display returns to a normal user display. Any changes made prior to the five minute time out
are incorporated. To quickly exit
SOFTENER SETUP
or
INSTALLER SETTINGS
, press SET HOUR and
DOWN.
Any changes made prior to the exit are incorporated.
SYSTEM SETUP
STEP 1SS
STEP 2SS
STEP 3SS
STEP 1SS
– From normal mode, press SET HOUR + UP buttons simultaneously for
3 seconds and release.
Then press SET HOUR + UP buttons simultaneously for 3 seconds and release.
STEP 2SS
– Choose the desired program by pressing the UP or DOWN buttons.
Press SET HOUR button to go to Step 3SS.
REGENERATION CYCLES & TIMES (minutes) FOR PROGRAMS PO-P9
Program
Number
C1
1st Backwash
C2
Regenerate
C3
2nd Backwash
C4
Fast Rinse
C5
Refill
P0
3
50
3
3
1-99
P1
8
50
8
4
1-99
P2
8
70
10
6
1-99
P3
12
70
12
8
1-99
P4
10
50
skipped
8
1-99
P5
4
50
4
1-99
P6
12
6
12
1-99
P7
6
skipped
4
skipped
P8
10
6
P9
14
8
Note: Cycle numbers that are skipped will not be displayed during regeneration
STEP 3SS
– If program P0 through P6 was selected, enter in the minutes of fill
using the UP or DOWN buttons. The allowable values vary from 1 to 99.
If program P7, P8 or P9 was selected, dashes will appear for minutes of fill.
Press SET HOUR button to go to Step 4SS. Note: For each minute of fill ½ gallon of
water is added to the solution tank. With salt (sodium or potassium chloride) this
equates to approximately 1
1
/
2
pounds of salt per minute of fill.
Press SET HOUR button to go to Step 4SS.