5
Installation of Feed Water Assembly
The system comes supplied with a saddle-type valve with mounting hardware and is intended to be used
on 3/8" to 1/2" copper tubing cold water supply line. NOTE: It is not to be used on flex lines.
a. Turn off cold water valve under the sink or main valve for the house.
b. Slide the clamp over the copper tubing and tighten the bottom screw firmly to hold the clamp in
position. (See Figure 4)
c.
Slide brass nut, plastic sleeve and tube insert on to the green 1/4" plastic tubing and thread onto valve
outlet.
d. Pierce the copper tubing by turning the needle valve handle (clockwise) until it is firmly seated. The
valve is closed in this position.
e. Turn on main supply valve to pressurize cold water line. Immediately check for any signs of leaks.
f.
When ready to supply water to the system, turn valve handle (counter-clockwise) until fully open.
Feed Water Assembly
Installation of Drain Saddle Assembly
The system comes supplied with a drain saddle and mounting hardware which fits around a standard 1½"
O.D.drain pipe (See Figure 5).
a. The saddle should be installed above the trap and on the vertical or horizontal tailpiece. It should never
be placed close to the outlet of a garbage disposal (See Figure 6).
b. Position saddle assembly on drain pipe to allow adequate space for drilling through pipe. If possible,
angle the drain saddle fitting toward spigot location.
c. Tighten the drain saddle screws evenly and firmly so a good seal is made. Avoid over tightening.
d. Drill a 5/16" hole in the drain pipe through the drain fitting opening. Support the drain against drilling
pressure.
e. Insert black drain line tubing into compression nut and tighten.