Now you can precisely control the comfort level of every room in your 

home with the Premier IntelliZone system. Working with your geother-

mal unit, electronic thermostat, and multiple motorized zone dampers 

installed in the duct system, the IntelliZone can eliminate temperature 

variations that occur throughout your home. 

This system allows you to control up to four zones individually. For 

example, you can heat only the bedrooms at night or cool or heat 

the downstairs sunroom during the day. Or you can improve comfort 

to areas that are troublesome. Typical temperature differences are 

eliminated in two or three story homes, especially with open-entry 

floor plans. 

IntelliZone provides savings by allowing operation in either a “com-

fort” or “economy” mode for each individual zone. Zones that require 

less precise temperature control can be set for “economy” mode while 

zones that require precise control are set for “comfort” mode. Unit 

staging (sequencing from first to second to third stage operation) is 

also selectable to best fit the needs of the application. 

Zoning is particularly useful where normal heat distribution patterns 

result in uneven temperature control. For example, a home that is partly below grade can use zoning to eliminate 

uneven temperature control between the basement and the rest of the home. Large homes that might have long, 

unequal length duct runs can use zoning to equalize the delivery of conditioned air. Homes with many large win-

dows can use zoning to compensate for solar heat gain and radiation losses at night. Zones can be determined by 

use, occupancy, location or outside exposure. 

Along with providing comfort, zoning can provide energy savings by keeping various zones at desired set points 

without over-cooling or over-heating other zones. In effect, the IntelliZone conditions only the portions (or zones) 

which need to be conditioned. This translates into shorter compressor run times and ultimately lower space condi-

tioning bills. 

The IntelliZone was designed to solve the typical problems of other ordinary zone control systems. Specifically, the 

IntelliZone eliminates the need for a bypass damper, works seamlessly with ECM variable speed blowers, uses mul-

tiple level zone calls, and is both easy to install and service. Many sizes of motorized dampers are available to meet 

the needs of a wide variety of applications. 

Maintenance

There is no user-maintenance required for the IntelliZone system or the motorized dampers. No lubrication is 

needed on the damper motors or gears. 

For more information on the IntelliZone system, contact your dealer. 

IntelliZone

PRODUCT INFORMATION FOR UNITS, OPTIONS & ACCESSORIES

Содержание OM2005A

Страница 1: ...Owner s Manual...

Страница 2: ...ny years of exceptional performance comfort and savings For a quick reference write your WaterFurnace Dealer s name telephone number and other important information below Company Name Telephone Number...

Страница 3: ...0 square ft Over 4000 square ft Location of Home Rural Suburban Urban Value of Home Under 100 000 100 000 to 200 000 200 001 to 500 000 Over 500 000 How did you hear about our products Check all that...

Страница 4: ...WATERFURNACE INTERNATIONAL ATTN WARRANTY REGISTRATION DEPT 9000 CONSERVATION WAY FORT WAYNE IN 46809 9794 Place Stamp Here...

Страница 5: ...hermostat Operation 24 TM21H02 Thermostat Operation 25 HOMEOWNER MAINTENANCE 26 27 TROUBLESHOOTING 28 FAQs GENERAL INFORMATION OPERATING TIPS 29 36 ENERGY SAVING TIPS 37 PRODUCT INFORMATION FOR UNITS...

Страница 6: ...workmanship Like your refrigerator your geothermal unit will provide many years of worry free operation Quiet Unlike ordinary air conditioners or heat pumps there is no noisy outdoor unit Our units ar...

Страница 7: ...represents 500 times more than mankind needs every year 5 units of heating or cooling delivered into your home 1 unit of electricity 4 units of free energy from the earth ABOUT YOUR WATERFURNACE SYST...

Страница 8: ...Water or water and anti freeze is circulated through the pipe transporting heat to the heat pump during the heating mode and away from the heat pump during the cooling mode The heat transfer takes pla...

Страница 9: ...per wall separating the two This heat transfer causes the cold liquid refrigerant to turn into a gas Unlike water refrigerant changes from a liquid into a gas at a very low temperature The now gaseous...

Страница 10: ...ow to go in the opposite direction that it was in the heating mode However the ow to the compressor does not change direction After compression the hot refrigerant passes through the coax the condense...

Страница 11: ...model and run time of the unit On very hot days and cold days the hot water generator could produce more hot water required for the home due to the long run times of the unit On milder days when the u...

Страница 12: ...loop earth coupled system include Geothermal unit placed on mounting pad Thermostat Earth loop piping Earth loop circulators pumps Electrical supply Duct system except for radiant oor heating systems...

Страница 13: ...enerator used Auxiliary heater if used Electrical Flexible Duct Collar Vibration Absorbing Pad P T Plugs Condensate Drain Desuperheater Connections Auxiliary Heater Knockout Low Voltage to Thermostat...

Страница 14: ...hen connected to a header system horizontally a few feet below the surface If you have this loop type record information here Number of bore holes _____ Depth of each bore hole _____ Pipe size _____ P...

Страница 15: ...loop is located Include the house and measurements from various points so that there is no question about the location of the piping system You may also want to include the location of any underground...

Страница 16: ...begin to clog the heat exchanger in the unit When this happens the ef ciency and capacity of the unit is decreased eventually to the point where failure may occur To minimize the potential of this ha...

Страница 17: ...nctions adhere to these safety precau tions Replacing a disposable lter Turn off the unit and fan at the thermostat Cleaning an electrostatic lter Turn off the unit and fan at the thermostat Cleaning...

Страница 18: ...d to be any factory installed component inside the unit including but not limited to the compressor reversing valve expansion valve electrical components air coil heat exchanger etc Upon failure of a...

Страница 19: ...he warranty cer ti cate carefully to familiarize yourself with the terms of the warranty so that you can obtain full bene ts and avoid misunderstandings If you have any questions about warranty covera...

Страница 20: ...ures and options along with a more aesthetically pleasing look Although these thermo stats are signi cantly more high tech you ll nd that they are easy to operate Note Most thermostats have an automat...

Страница 21: ...instructions on usage These thermostats also come with an individual Owner s Guide which includes additional information For thermostats NOT shown here refer to separate Owner s Guides EW Series with...

Страница 22: ...operating in either the rst or second stage heating mode The ENERGY SAVINGS on the display is not illuminated when auxiliary heat is being used Note If your system is not equipped with auxiliary heat...

Страница 23: ...during this time if possible Call your WaterFurnace dealer If the thermostat displays a fast ashing TROUBLE about 3 ashes second the unit is locked out due to insuf cient air ow Reset the unit see pa...

Страница 24: ...red Wake time is displayed The program times are in fteen minute inter vals Example 8 00 8 15 8 30 4 Press INCREASE or DECREASE key until the desired Wake temperature is displayed The setpoint tempera...

Страница 25: ...between heating and cooling operation depending on the indoor temperature Fan settings control the system fan as follows On Fan operates continuously Auto Fan operates with equipment VIEWING AND RESET...

Страница 26: ...n and air quality EMERGENCY HEAT The Emergency Heat feature allows you to turn on the backup heat section of the system by moving the System switch to the Em Ht position The thermostat shows Em Ht in...

Страница 27: ...quipment has failed or is not working properly EM HT AND AUX HT INDICATIONS The indicator points to either Em Ht or Aux Ht when these modes are active Em Ht The indicator points to Em Ht when the SYST...

Страница 28: ...erFurnace dealer Electrostatic Filters Clean every 1 2 months If you use an electrostatic lter clean it regularly See page 51 for instructions Electronic Air Cleaners Clean and replace media every 2 4...

Страница 29: ...sable lter Clean electrostatic lter if used Clean electronic air cleaner if used Check condensate drain pan Check duct system Check thermostat operation and signals Visual check of unit LEDs Visual ch...

Страница 30: ...change Check setpoints for both heating and cooling 18 Thermostat backlight ashes on TA32U02 thermostat Check status fault lights on unit See thermostat instructions 30 31 20 21 Red LED on at thermost...

Страница 31: ...system you ll nd this information valuable Geothermal systems do function differently than ordinary systems However by using this section as a reference you ll be able to nd answers to the most commo...

Страница 32: ...ration has ceased look at the thermostat to see if the unit lockout indicator light is illuminated If the lockout indicator light is illuminated see resetting the unit section page 31 What about regul...

Страница 33: ...ol which is the brain of the unit is operat ing properly If the light doesn t ash but remains continuously on or off the control is inoperative Turn off all power to the unit including auxiliary heat...

Страница 34: ...sily washed Never run the unit without a lter The frequency in which you should clean or replace your lter is dependent upon several variables including the type of lter media your outdoor environment...

Страница 35: ...water assist is a function of how long the unit is running and in what mode it is in With the hot water assist more water is heated in the cooling mode than in the heating mode For more information se...

Страница 36: ...few min utes followed by a cooling off period then another blast of hot air and on and on This type of operation results in ever changing indoor temperatures and hot cold spots within the home This fr...

Страница 37: ...so that the air is fully circulated throughout the various rooms to minimize hot spots or cold spots When the guests leave and occupancy levels return to normal be sure to switch back to heating mode...

Страница 38: ...sanitized in any way Indoor air quality can be improved using special ultra violet UVC lights placed in the air distribution system Al though these lights do not remove any contaminants you ll still n...

Страница 39: ...cient to seal leaks in a duct system Over time the adhesive used on duct tape will dry out resulting in tape failure Other tape types and sealants used by professional HVAC contractors are better sui...

Страница 40: ...e experienced the information provided here will help you to better understand the speci c features of your unit We have also included information on major options and accessories how they work and wh...

Страница 41: ...n our product line and within each family are one or more models The four families of units are E Series Premier Synergy3 Versatec If your unit has a model number starting with E you have an E Series...

Страница 42: ...various fault conditions see page 16 The microprocessor also provides easy to use trouble shooting features and on board diagnostics for your dealer to quickly identify and resolve service issues Saf...

Страница 43: ...acity does not satisfy the thermostat the unit will automatically change to second stage full capacity compressor operation In order to change from rst stage to second stage units with dual capacity c...

Страница 44: ...ow will change the setpoint by one degree In addition to the water temperature display the control panel also has 6 LED indicators that indicate when the unit is in one of the following modes Lockout...

Страница 45: ...freeze protection and fan start detection In the unlikely event of a compressor failure the emergency heat is enabled to satisfy heating requirements Another sensor detects if the condensate drain pan...

Страница 46: ...air handler or furnace is equipped with a variable speed blower you may notice the fan speed change depending on the mode of operation All Premier splits feature reliable and ef cient Scroll compress...

Страница 47: ...abled to satisfy heating requirements Another sensor detects if the con densate drain pan is full at which time the unit will be shut down for protection against water leaks see page 18 Depending on t...

Страница 48: ...t your dealer for service In northern climates Versatec units may include an optional duct mounted auxiliary heater In the unlikely event of a compressor failure the auxiliary heater will provide emer...

Страница 49: ...heater could generate more hot water required for the home due to the long run times of the unit On milder days when the unit has short duty cycles the electric elements in the water heater will maint...

Страница 50: ...example Installation Option A The geothermal unit is sized to provide 95 of your heating requirement with the other 5 using the auxiliary electric Installation Option B The geothermal unit is sized t...

Страница 51: ...ement Instead water is distributed over a rotating disk wheel Air passing through the humidi er picks up the moisture from the disk wheel and is routed into the home through the duct system providing...

Страница 52: ...e of the unit On the Powerhead of the air cleaner unplug the adapter cord Make sure that the jack does not touch any metallic or grounded surfaces which could result in possible damage to the unit Rem...

Страница 53: ...buildup is very heavy you may want to use a vacuum cleaner hose to remove the bulk of the accumula tion This may not be necessary unless the lter is very dirty Spray the lter on both sides with a hou...

Страница 54: ...or the use of a single larger pump or possibly separate loops and pumps for each unit Units using well water do not use a ow center Rather they use the well pump Maintenance Flow centers and pumps req...

Страница 55: ...ning to eliminate uneven temperature control between the basement and the rest of the home Large homes that might have long unequal length duct runs can use zoning to equalize the delivery of conditio...

Страница 56: ...1999 Some manufacturers market HEPA lters that may not technically meet the standard Many true HEPA systems include a pre lter for larger particles a carbon odor lter and the actual HEPA media Because...

Страница 57: ...t a great variety of name brand shirts jackets caps and other items with the WaterFurnace logo To view our complete product selection go to www waterfurnacestore com or www waterfurnacepromo com All p...

Страница 58: ...e natural gas propane fuel oil oil and coal GPM Gallons per Minute A reference to the ow rate of water through the geothermal unit Heat Exchanger A device designed to transfer heat between two physica...

Страница 59: ...2022 2023 2024 2025 2026 2027 2028 2029 2030 PREVENTIVE MAINTENANCE SERVICE RECORD PREVENTIVE MAINTENANCE SERVICE RECORD In order to keep your system operating at peak performance levels WaterFurnace...

Страница 60: ...Document Type Owner s Manual Part Number OM2005A Release Date 1 05...

Отзывы: