42
EW Series Hydronic units can be used in a variety of applica-
tions including domestic hot water, radiant floor heating, pool/
spa heating, fan coils, and even snow melt.
A sophisticated microprocessor controls the pumps and
compressor by sampling water temperatures even during “off”
cycles. The controller enables the user to view all modes of
operation and easily adjust setpoint temperatures. This control
has a wide range of set-up flexibility to meet the variety of ap-
plications in which the unit can be installed. However, configu-
ration of the control is done only at the time of installation as
it requires special codes and a thorough understanding of the
application and the control sequence.
Generally, the unit will be set and controlled automatically to
provide the correct temperature water. However, you can view
the setpoint, by pressing the ▲ or ▼ arrow once (the display
on the control panel will begin flashing). Subsequent presses
of either the ▲ or ▼ arrow will change the setpoint by one
degree.
In addition to the water temperature display, the control panel
also has 6 LED indicators that indicate when the unit is in one
of the following modes: Lockout, Standby, Primary, Heating,
Cooling, or Secondary Mode. To change modes, press the
mode button.
To protect the unit, the control monitors functions and conditions within the system. In the event of a failure or
unsafe condition, the unit will go into Lockout mode. During lockout mode, the display will flash the lockout code cor-
responding to the fault condition. The compressor, pumps, and secondary output are de-energized. Lockout modes
of any kind can be reset by pressing the mode button twice. Turning off the unit’s breaker (and then back on after
60 seconds) also resets the lockout. Do not repeatedly reset the lockout. Doing so could damage the unit or other
components in the system. Contact your dealer to resolve the problem.
EW units include Scroll compressors and R-410A refrigerant for exceptional efficiency and performance. These
units are ENERGY STAR® qualified and safety certified by ETL.
EW Series Units
PRODUCT INFORMATION FOR UNITS, OPTIONS & ACCESSORIES
Содержание OM2005A
Страница 1: ...Owner s Manual...
Страница 60: ...Document Type Owner s Manual Part Number OM2005A Release Date 1 05...