background image

26

Waterford TARA T25 Direct Vent Freestanding Gas Stove

OPTIONAL

FRONT GRILL

1)

Remove the Cast Iron Front Panel. Catch the
cast iron front panel at the bottom and lift
upwards and out from the stove. Once free
of the locating tabs, the panel can be dropped
down; freeing it from the top of the stove.

Place the cast iron front panel on a non-
abrasive surface, away from any traffic to
ensure that it does not get damaged.

2) Lay the grill into position on the inside of the

Cast Iron Front Panel and secure using the
2 screws provided.

REMOVING

THE CAST IRON

FRONT PANEL

1) Hold the cast iron front panel at the bottom

and lift upwards and out from the stove.
Once free of the locating tabs, the panel can
be dropped down; freeing it from the top of
the stove.

Place the cast iron front panel on a non-
abrasive surface, away from any traffic to
ensure that it does not get damaged.

2) Remove the Front Glass Panel. Using a 7/16"

socket wrench, remove the 6 hex head
bolts used to secure the glass panel and
frame to the stove. Remove the frame and
glass panel and set it aside.

Securing the

Cast Iron Front Panel

1) Catch the panel in the viewing area and on

the bottom edge.

2) Place the front panel against the stove just

below the top panel.

3) Slide the panel upwards under the top

panel. When the top is in position, push the
bottom edge into position. Push downwards
to secure the locating pins in the locating
tabs.

AERATION

ADJUSTMENT

The burner aeration is factory set but may need
adjusting due to either the local gas supply, air
supply or altitude. The flames should not extend
to the top of the firebox and excessive soot
should not be present. The air shutter and the
flue restrictor setting will both affect the flame
pattern.

Natural Gas:

1/4" (7mm) open

Propane:

wide open

1) Remove the Front Cast Iron Panel and Glass

Panel, see instructions on page 26.

2) Remove the complete log set. (See Log

Installation instructions on page 27).

3) Using a 1/4" nut driver or flat screwdriver,

loosen the locking screw on the burner air
shutter.

INSTALLATION

8) Using the 1/4" nut driver or flat screwdriv-

er, tighten the locking screw on the burner
air shutter.

9) Replace the log set, glass panel and Cast

Iron Front Panel.

Caution: Carbon will be produced if the
air shutter is closed too much.

Note: Any damage due to carboning

resulting from improperly setting
the aeration controls is NOT cov-
ered under warranty.

Note: Aeration Adjustment should only

be performed by an authorized
Regency Installer at the time of
installation or service.

4) Replace the log set, and glass panel.

5) Insert a 3/16" Allen wrench into the adjust-

ing key (through) the hole on the rear panel
of the stove).

6) Turn the mechanism until to change the

flame pattern. Turning clockwise will dimin-
ish the flame, and turning counter-clock-
wise will increase the flame.  The rear flame
must not extend and touch the top of the
firebox and no soot should be forming on
any surfaces.

7) Remove the glass panel, and the log set.

Содержание TARA T25-LP

Страница 1: ...the gas supplier FOR YOUR SAFETY What to do if you smell gas Do not try to light any appliance Do not touch any electrical switch do not use any phone in your building Immediately call your gas suppli...

Страница 2: ...h TheTARAhasbeen approved by Warnock Hersey for both safety and efficiency As it also bears our own mark it promises to provide you with economy comfort and security for many trouble free years to fol...

Страница 3: ...Label Safety Labels 4 Installation Information for Mobile Manufactured Home After First Sale 5 Before You Start 5 Manufactured Mobile Home Requirements 6 General Safety Information 6 Installation Chec...

Страница 4: ...l for TARA T25 Gas Stove NOTE Waterford units are constantly being improved Check the label on the unit and if there is a difference the label on the unit is the correct one For the State of Massachus...

Страница 5: ...A QUALIFIED SERVICE PERSON MORE FREQUENT CLEANING MAY BE REQUIRED DUE TO EXCESSIVE LINT FROM CARPETING ETC IT IS IMPERATIVE THAT THE CONTROL COMPARTMENT BURNERS AND CIRCULATINGAIRPASSAGEWAYS BEFORE YO...

Страница 6: ...on More frequent cleaning may be re quiredduetoexcessivelintfromcarpeting bedding material etc It is imperative that control compartments and circulating air passageways of the appliance be kept clean...

Страница 7: ...ct the red and black wires from the wire harness to speed controller NOTE Speed control wires must be in the down position when control panel is in place INSTALLATION Use the minimum clearances shown...

Страница 8: ...Pull excess wire next to fan to avoid excessive heat from the firebox 11 Slide the thermodisc into the bracket clip on the underside of the firebox NOTE When power cord is plugged in speed control is...

Страница 9: ...in the Exterior Vent Terminal Locations diagram on page 10 INSTALLATION PRECAUTIONS These venting systems are engineered prod ucts that have been designed and tested for use with the Tara Thewarranty...

Страница 10: ...ter regulator assembly within 3 90cm horizontally from the centerline of the regulator J Clearance to service regulator vent outlet min 36 90cm K Clearance to non mechanical air supply inlet to buildi...

Страница 11: ...h the wall ensure that ALL vent and termination clearances see page 10 will be met The venting arrangements shown on the dia gram have a minimum of 75 flue loss efficiency with Fan Off as required for...

Страница 12: ...e same installation procedures as used for standard Horizon tal Termination NEVER install the snorkel upside down Diagram 1 Dia 2a 2b As speci fied in CGA B149 Instal lationCode Localcodes or regulati...

Страница 13: ...and the vent cap by attaching the two sheet metal strips extending from the Riser Vent Back ingPlateintotheouterwalloftheventpipe Use two aluminum screws provided to connectthestripstothepipesection B...

Страница 14: ...ild up may occur Be sure to check vent termination area after snow falls and clear to prevent acciden tal blockage of venting system When using snow blowers make sure snow is not directed towards vent...

Страница 15: ...e 4 dia flex liner out fully and get a trial fit of the liner onto the 4 dia starter collar 8 Cut the 4 dia flex liner to the desired size Hint leaveanextra12 to16 oflength this will make the final as...

Страница 16: ...our particular installa tion See page 15 for a list of vent parts If installing termination on a siding covered wall a vinyl siding standoff or furring strips can be used in order to ensure that the t...

Страница 17: ...5O Elbow Swivel Black 945BG N A N A 90O Elbow Galvinized 990 4DT EL90S 4D90LS 90O Elbow Black 990B 4DT EL90SB 4D90LBS 90O Elbow Swivel Galvinized 990G N A N A 90O Elbow Swivel Black 990BG N A N A Ceil...

Страница 18: ...CLOSED in a chase min size 9 x 9 maintain a 1 1 4 clearance to combustibles Offset to Vertical Terminations Vent Restrictor must be set at 5 8 for this venting installation Straight Vertical Terminati...

Страница 19: ...pipes and fittings by ori enting the four pipe indentations so they match and slide in to the four entry slots on the male ends dia gram1 Pushthepipesectionscom pletely together thentwist lockone sect...

Страница 20: ...enetrate the roof Determine if ceiling joists roof rafters or other framingwillobstructthevent ing system You may wish to relocate the applianceortooffset asshownindiagram 6 to avoid cutting load bear...

Страница 21: ...10 INSTALLATION b Any occupied areas above the first floor including closets and storage spaces through which the vertical vent passes must be enclosed Support Extensions Round RDSE or Square SQSE St...

Страница 22: ...76mm Connect the flex pipe to the Retro Connector by slipping it into the 4 3 4 diametersleeveonthetopsideofthe Connector Use 3 sheet metal screws to assemble these two parts 6 Push the flex pipe bac...

Страница 23: ...Diagram 9 9 Slide the Wall Thimble Cover Part 940 over the Retro Connector and secure with masonry bolts Diagram 10 If you have a framed wall in front of the masonry use wood screws to mount the Wall...

Страница 24: ...es Since somemunicipalitieshaveadditionallocalcodes it is always best to consult with your local authorities and the CAN CGA B149 installation codes ForUSAinstallationsfollowlocalcodesand or the curre...

Страница 25: ...rner onto the burner injector The burner air shutter gears must be aligned Check to make sure that the two gears engageeachotherbyatleasttwo thirdsof their thickness If not it will be necessary to dis...

Страница 26: ...g pins in the locating tabs AERATION ADJUSTMENT Theburneraerationisfactorysetbutmayneed adjusting due to either the local gas supply air supplyoraltitude Theflamesshouldnotextend to the top of the fir...

Страница 27: ...5 logs in the set 1 Rear Log 1 Front Log 1 Middle Log and 2 Top Logs The logs are fragile handle with care DONOT FORCEinto position 1 RemovetheCastIronFrontPanel seepage 26 2 Remove the Front Glass P...

Страница 28: ...to the product that causes sooting or carboning that results in damage to the exterior facia is not the responsibility of the manufacturer Thermostat Wire Table The remote control kit comes with a han...

Страница 29: ...oturn on the unit 6 Rotate the flame height regulator to adjust the flame height higher or lower SHUTDOWN PROCEDURE 1 Usethethermostatorremotecontroltoturn off the main burner 2 Turn the main gas cont...

Страница 30: ...nt gauge material from the rest of the firebox and body Therefore the varying thick nesses of steel will expand and contract at slightly different rates which can cause tick ing and cracking sounds Yo...

Страница 31: ...er operate the appliance without the glass properly secured in place or with the door open 9 Periodically check the pilot flames Correct flamepatternhasthreestrongblueflames 1 flowing around the therm...

Страница 32: ...impact purchase your replacement door from an authorized Waterford dealer only and follow our step by step instructions for re placement Replacement Part W260040 Tara Glass WARNING Do not operate app...

Страница 33: ...2081 Hob Casting Black 30 W260260 Top Relief Frame Gasket 31 942 117 Top Relief Plate Frame 32 W260280 Top Relief Plate Gasket 33 290 021 Air Baffle Plate 41 W260061 Side Casting Black 42 W420011 Leg...

Страница 34: ...____________________________ ______________________________________________________ _______________________________________________________________ ____________________________________________________...

Страница 35: ...ned to FPI and evaluated for manufacturer defect The authorized selling dealer is responsible for all in field service work carried out on your Waterford product FPI will not be liable for results or...

Страница 36: ..._______________________________________________ Printed in Canada Waterford fireplace products are designed with reliability and simplicity in mind In addition our internal Quality Assurance Team care...

Отзывы: