![Waterco Side Discharge Скачать руководство пользователя страница 33](http://html.mh-extra.com/html/waterco/side-discharge/side-discharge_user-and-care-manual-manual_874796033.webp)
I pg 32
Pool Heat Pump
Code
Problem - Action / Remedy
HP, HP3
Action / Remedy:
Make sure the water reaches the pool heat pump
and the pool pump is completely filled to the rim. Otherwise:
- Fill the pool pump with water, and check to see if the pipes
between the pool pump and the pool are watertight (there should
be no air intake);
- Check the swimming pool and pool skimmer baskets and the drain
at the bottom of the pool for obstructions;
- Check the filter cartridges for obstructions (wash or change the
cartridges, as the case may be);
- Insure that the bypass valves are in the correct positions so that
the water flows adequately;
- Backwash sand filter (insure that there is a sufficient amount of
sand and verify that it does not have to be changed. Consult a
swimming pool specialist if necessary);
- Make sure the vacuum robot is disconnected so that the water
flows freely.
OFF
Problem:
The desired water temperature setting programmed is
below 60°F (15°C) for the Multi function electronic control OR the
electronic control with diagnostics is OFF or could be defective.
Action / Remedy:
Reprogram the desired water temperature setting
to a higher setting for the electronic control with Multi Function. For
the electronic control with diagnostics and the reversible electronic
control with diagnostics (XLR), press on key ¨ON/OFF¨.
PSD, oC1 &
Sc1
Problem:
The water temperature probe has a loose connection or is
faulty. The probe will need to be checked and replaced if required.
Action / Remedy:
Contact customer service.
ot
Problem:
Water temperature is higher than 45°C (113°F) within
the unit (this code is only displayed on the electronic control with
diagnostics).
Action / Remedy:
- Make sure the bypass valves are in the correct positions;
- Proceed to the calibration of the electronic control with diagnotics
and reversible electronic control with diagnostics (XLR).