IMPORTANCE OF WATER CHEMISTRY
The digiHeat has been carefully designed to withstand the harsh environment of a spa
system, and non metallic materials are used extensively. Where metals parts are used
however such as heater elements it is important the water is chemically balanced to ensure
it is not corrosive or scale forming. Waterco will not be responsible for damage caused by
corrosion or scaling.
The chemical balance of water is a relationship between its pH, total alkalinity, calcium
hardness and temperature. your professional pool or spa shop can test the water to ensure
it is chemically balanced in accordance with the langelier Saturation Index.
The water must be maintained at all times as per the following:
pH level
: between 7.2 & 7.8.
total alkalinity
: between 80 & 150ppm.
calcium hardness
: between 150 & 300ppm.
And within these tolerances to be balanced to the langelier Saturation Index within a range
of : -0.2 to +0.2
Digiheat Titanium
models are fitted with titanium elements and provide high resistance to
ozone, iodine, baquacil, salt and chlorinated water.
digiheat Titanium In line Spa Heaters I 05