ENG 11
Instructions to use Quick Fittings
Your Reverse Osmosis Water Purifier is outfitted with the new generation
of userfriendly “quick fittings”.
Proper use of the fittings is shown in the diagrams below.
To Attach Tubing
Push tubing straight in as far as it will go.
Tubing is secured in position.
To Insert Locking Clip
Push in collet to release tubing.
To Release Tubing
Locking clip slides between collet and fitting.
It is important that the tubing selected for use with these connectors be
of high quality, exact size and roundness, and with no surface nicks or
scratches. If it is necessary to cut the tubing, use a plastic tubing cutter or
sharp razor knife, make a clean, square cut.
If there is leakage at a fitting, the cause is usually a defective tubing end
cut. To fix this problem, follow below steps:
•
Relieve pressure.
•
Release tubing.
•
Cut off at least 1/4” from end.
•
Reattach tubing.
•
Confirm connection is leak free.
Diagram 4
Diagram 6
Diagram 7
Diagram 5
Collet
Clip
(Before Installation)
Clip
(After Installation)
Tubing
Tubing