1.  

GENERAL OPERATION:

 

When the system is operating, one of three displays 

may be shown. Pressing 

NEXT

 will alternate between the displays. One of 

the displays is always the current time of day. The second display shows the 
current treated water flow rate through the system in Gallons Per Minute. The 
third display is one of the following: days remaining or volume remaining. 
Days remaining is the number of days left before the system goes through a 
regeneration cycle. Capacity remaining is the gallons that will be treated before 
the system goes through a regeneration cycle. The user can scroll between the 
displays as desired. 

     If a water meter is installed, the word “Softening” or “Filtering” flashes on the 

display when water is being treated (i.e. water is flowing through the system).

2.  

REGENERATION MODE:

 

Typically a system is set to regenerate 

at a time of no water use. If there is a demand for water when the system 
is regenerating, untreated water will be delivered. When the system begins 
to regenerate, the display will change to include information about the 
step of the regeneration process and the time remaining for that step to be 
completed. The system runs through the steps automatically and will reset itself 
to provide treated water when the regeneration has been completed.

3.  

MANUAL REGENERATION:

 

Sometimes there is a need to regenerate before 

the control valve calls for it. This may be needed if a period of heavy water use 
is anticipated or when the system has been operated without salt.

 • 

 

To initiate a manual regeneration 

at the next preset regeneration time,

 press 

and release 

REGEN

. The words “REGEN TODAY” will flash   on the display 

to indicate that the system will regenerate at the next regeneration time (set 
in Programming, steps 4 and 5). 

If you pressed the 

REGEN

 button in error, 

pressing the button again will cancel the command.

 • 

 

To initiate a manual regeneration 

immediately,

 press and hold  

the 

REGEN

 button for three seconds. The system will begin to regenerate 

immediately. 

This command cannot be cancelled.

      Once a manual regeneration is initiated, the unit will go into the FILL position. This 

position allows water to enter the brine tank until it reaches the proper level. Once 
this position is complete, you will notice a 240 Minute (4 hours) SOFTENING 
position. This 4-hour window allows the salt to dissolve and achieve proper brine 
strength. During these FILL and SOFTENING positions, you will have softened 
water available for use. Once the unit advances to the BACKWASH position 
and subsequent positions thereafter (see Start Up Instructions for regeneration 
sequence), the water softener will deliver water, but it will be untreated. 

     

 IMPORTANT:

 With the Dry Salt Storage Feature, the brine tank will refill 4 hours 

before the actual regeneration occurs. You may experience a small amount of 
noise for a short period of time at 10:00 p.m. (with typical setting) on the night 
that regeneration is to occur. This noise is only the brine tank filling and at no time 
during this process will you be without treated water. 

4.   

POWER LOSS AND BATTERY REPLACEMENT:

 

The AC transformer comes with 

a 15 foot power cord and is designed for use with the control valve; the transformer 
should only be used in a dry location. 

      In the event of a power outage that is less than 24 hours, the control valve will 

remember all settings and time of day. After 24 hours, the only item that needs to 
be reset is the time of day and will be indicated by the time of day flashing. All 
other settings are permanently stored in the nonvolatile memory.

  

   

 If a power loss occurs that 

is less than 24 hours and the time of day flashes, 

this 

indicates that the battery is depleted. The time of day should be reset and the 
non-rechargeable battery should be replaced. The battery is a 3 Volt Lithium Coin 
Cell type 2032 and is readily available at most stores. To access battery location, 
remove front cover (

see diagram on page 14 for battery location).

 OPERATING DISPLAYS AND INSTRUCTIONS:

GENERAL OPERATION DISPLAYS

REGENERATION MODE

MANUAL REGENERATION

BATTERY REPLACEMENT

9

Содержание UCS-1044

Страница 1: ...For Models UCS 844 UCS 948 UCS 1044 UCS 1054 UCS 1248 UCS 1354 CareSoft Series Metered Water Softeners...

Страница 2: ...73 TABLE OF CONTENTS Preinstallation Instructions for Dealers 3 Bypass Valve 4 Installation 5 6 Programming Procedures 7 8 Operating Displays and Instructions 9 10 Start up Instructions 11 12 Troubles...

Страница 3: ...During operation the normal user display is time of day and gallons per minute Flow Rate Vacation Mode Capacity Remaining and Days to a Regeneration are optional displays but are not normally used Vac...

Страница 4: ...regeneration water to the unit while also providing untreated water to the distribution system Fig 1 2 BYPASS POSITION The inlet and outlet handles point to the center of the bypass The system is iso...

Страница 5: ...tank it should be located where it is easily accessible 3 Do not install any water conditioner with less than 10 feet of piping between its outlet and the inlet of a water heater 4 Do not locate unit...

Страница 6: ...mmended Where the drain empties into an overhead sewer line a sink type trap must be used Run drain tube to its discharge point in accordance with plumbing codes Pay special attention to codes for air...

Страница 7: ...E If a resin media is used in the softener increase the grains per gallon if soluble iron is present 1 ppm 4 gpg This display will show nA not available if FILTER is selected or if AUTO is not factory...

Страница 8: ...immediate manual regeneration press and hold the REGEN button for three seconds The system will begin to regenerate immediately The control may be manually stepped through the regeneration cycles by p...

Страница 9: ...n for three seconds The system will begin to regenerate immediately This command cannot be cancelled Once a manual regeneration is initiated the unit will go into the FILL position This position allow...

Страница 10: ...eration the manufacturer recommends the use of solar salt for best results The brine tank is manufactured for the use of solar pellets or rock salt Do not use block salt If pellet or rock salt is used...

Страница 11: ...EGEN again and the display will read SOFTENING 240 During a full regeneration this will be a 4 hour period for salt to dissolve Press REGEN again to put the valve into BACKWASH Once valve has stopped...

Страница 12: ...brine well cover 2 Pour 1 oz of household bleach into the softener brine well 3 Replace brine well cover NOTE Avoid pouring bleach directly onto the safety float components in the brine well Unit sani...

Страница 13: ...d meter turbine C Remove meter and check for rotation or foreign material D Meter wire not installed securely into three pin connector D Verify meter cable wires are installed securely into three pin...

Страница 14: ...tank G Check refill setting in programming Check refill flow control for restrictions or debris and clean or replace H Damaged seal stack assembly H Replace seal stack assembly I Control valve body t...

Страница 15: ...on or disconnect power supply from PC board for 5 seconds and then reconnect B PC board not properly snapped into drive bracket B Properly snap PC board into drive bracket and then Press NEXT and REGE...

Страница 16: ...conds to resynchronize software with piston position or disconnect power supply from PC board for 5 seconds and then reconnect Then reprogram valve to proper setting B MAV NHBP motor wire not connecte...

Страница 17: ...cover 1 2 CV3107 1 Motor 1 3 CV3106 1 Drive bracket spring clip 1 4 CV3851WN PC board 1 5 CV3110 Drive gear 12 x 36 3 6 CV3109 Drive gear cover 1 7 CV3002CC Drive assembly CV3186 Transformer 110V 12V...

Страница 18: ...35 O ring 228 1 4 CV3011 1 piston assembly downflow 1 CV3011 01 1 piston assembly upflow 1 CV3407 1 25 piston assembly downflow 1 5 CV3174 Regenerant piston 1 6 CV3180 O ring 337 1 7 CV3105 O ring 215...

Страница 19: ...t 1 quick connect 2 2 CV3150 Split ring 2 3 CV3105 O ring 215 2 4 CV3145 Bypass rotor 1 2 5 CV3146 Bypass cap 2 6 CV3147 Bypass handle 2 7 CV3148 Bypass rotor seal retainer 2 8 CV3152 O ring 135 2 9 C...

Страница 20: ...BLUE CV3010 1G G injector assembly YELLOW CV3010 1H H injector assembly GREEN CV3010 1I I injector assembly ORANGE CV3010 1J J injector assembly LIGHT BLUE CV3010 1K K injector assembly LIGHT GREEN n...

Страница 21: ...bow CV3162 022 2 2 DLFC for 3 4 elbow CV3162 027 2 7 DLFC for 3 4 elbow CV3162 032 3 2 DLFC for 3 4 elbow CV3162 042 4 2 DLFC for 3 4 elbow CV3162 053 5 3 DLFC for 3 4 elbow CV3162 065 6 5 DLFC for 3...

Страница 22: ...8 01 Turbine assembly 1 4 CV3105 O ring 215 1 5 CV3003 01 Meter plug assembly 1 6 CV3013 Optional mixing valve 1 Although no tools are necessary to assemble or disassemble the valve the Service Wrench...

Страница 23: ...onal 18 diameter salt grid 1 CH1080 Optional 24 diameter salt grid 1 3 CG21833CB1C00 18 x 33 brine tank black 1 CG21840CB1C00 18 x 40 brine tank black 1 CG22441CB1C00 24 x 41 brine tank black 1 4 CH10...

Страница 24: ...1 brass sweat assembly 2 1 CV3151 Nut 1 quick connect 2 2 CV3150 Split ring 2 3 CV3105 O ring 215 2 4 CV3188 Fitting 2 3 4 BRASS SWEAT Item No Part No Description Qty CV3007 03 3 4 brass sweat assemb...

Страница 25: ...te assembly 2 1 CV3151 Nut 1 quick connect 2 2 CV3150 Split ring 2 3 CV3105 O ring 215 2 4 CV3629 Fitting 2 3 4 BRASS SHARK BITE Item No Part No Description Qty CV3007 12 3 4 brass Shark Bite assembly...

Страница 26: ...o Max Working Pressure PSI 30 100 30 100 30 100 30 100 30 100 30 100 Min to Max Operating Temperature F 33 100 33 100 33 100 33 100 33 100 33 100 Max Flow to Drain During Regeneration GPM 1 3 1 7 2 2...

Страница 27: ...xpense and return part freight collect The above provisions of the warranty are valid as long as the unit is connected in compliance with local plumbing codes and in an equivalent manner and condition...

Страница 28: ...ness display shows nA if used as a filter If other displays do not appear refer to manual GENERAL OPERATION When the system is operating one of three displays will be shown time of day gallons of trea...

Отзывы: