PAUL
®
station
manual
page 23
PAUL Station Manual 2019-08-02
6 Maintenance
6.1 Daily
6.1.1 Water level inside
PAUL
®
The water level inside
PAUL
®
should be checked daily. If the water level is con-
siderably low, the
PAUL
®
is able to filter more water than he gets from the
RWT, which might be caused by a dirty sieve, see chapter 6.1.2.
If it is detected, that the water level is low, less than half the height of
PAUL
®
,
the close the valve in the connection between
PAUL
®
and the FWT and fill up
PAUL
®
with some water. Make sure enogh raw water is available.
6.1.2 Sieve between RWT and
PAUL
®
The sieve that is mounted between the Raw Water Tank and
PAUL
®
should be
checked daily. If it is obstructed, please clean carefully.
If cleaning of the sieve is frequently necessary due to a high Suspended Solids
content of the raw water, maybe a different location of the tank connector in the
RWT might help (maybe it is placed too close to the bottom of the tank where
settleable solids accumulate).
Alternatively, a larger sieve would be necessary. This can be obtained by us
upon request..
6.2 Weekly
6.2.1 Removing slurry from the
PAUL
®
unit
All particles that
PAUL
®
filters stay in the blue body of
PAUL
®
. Thus, they must
be removed on a regular basis.
This can be done by opening the bottom outlet underneath or on the side of
PAUL
®
, whatever is easier.
Flush out the slurry, discard it the same way you do with toilet content, and
close the outlet.