Water Worker G-5 Скачать руководство пользователя страница 2

READ 

CAREFULLY 

THE 

PRODUCT 

INSTALLATION, 

OPERATING 

AND 

MAINTENANCE  MANUAL.    FAILURE  TO  FOLLOW  THE 
INSTRUCTIONS  AND  WARNINGS  IN  THE  MANUAL  MAY 
RESULT IN SERIOUS OR FATAL INJURY AND/OR PROPERTY 
DAMAGE,  AND  WILL  VOID  THE  PRODUCT  WARRANTY.  
THIS  PRODUCT  MUST  BE  INSTALLED  BY  A  QUALIFIED 
PROFESSIONAL.    FOLLOW  ALL  APPLICABLE  LOCAL  AND 
STATE  CODES  AND  REGULATIONS,  IN  THE  ABSENCE  OF 
SUCH CODES, FOLLOW THE CURRENT EDITIONS OF THE 
NATIONAL  PLUMBING  CODE  AND  NATIONAL  ELECTRIC 
CODE, AS APPLICABLE.

This  product  must  be  installed  by  a  qualified 
professional.

EXPLOSION  HAZARD.

  Failure  to  follow  the 

instructions in the accompanying product manual 

can cause a rupture or explosion; possibly causing serious or fatal 
injury, leaking or flooding and/or property damage.

Use  only  with  potable  water  system.    Do  not 
operate  in  a  setting  with  freezing  temperatures 

or  where  the  temperature  can  exceed  200°F  and  do  not  exceed 
the  maximum  working  pressure  specified  for  this  Product  in  the 
Manual.  Mount vertically only.

This Product, like most Products under pressure, 
may  over  time  corrode.  weaken  and  burst  or 

explode, causing serious or fatal injury, leaking or flooding and/or 
property damage.  To minimize risk, a licensed professional must 
install  and  periodically  inspect  and  service  the  Product.    A  drip 
pan connected to an adequate drain must be installed if leaking or 
flooding could cause property damage.  Do not locate in an area 
where  leakage  of  the  tank  or  connections  could  cause  property 
damage to the area adjacent to the appliance or to lower floors of 
the structure.

Chlorine & Aggressive Water:

 The water quality 

can  significantly  influence  the  life  of  this  Product.  

You  should  test  for  corrosive  elements,  acidity,  total  solids  and 
other  relevant  contaminants,  including  chlorine  and  treat  your 
water appropriately to insure satisfactory performance and prevent 
premature failure.

CALIFORNIA  PROPOSITION  65  WARNING:

 

This  product  contains  a  chemical  known  by  the 

State  of  California  to  cause  cancer  and  to  cause  birth  defects  or 
other reproductive harm. (California Installer/Contractor - California 
law requires that this notice be given to consumer/end user of this 
product.) For more information:  www.amtrol.com/prop65/htm.

THIS  IS  THE  SAFETY  ALERT  SYMBOL.    IT  IS  USED 
TO  ALERT  YOU  TO  POTENTIAL  PERSONAL  INJURY 

AND  OTHER  HAZARDS.    OBEY  ALL  SAFETY  MESSAGES 
THAT  FOLLOW  THIS  SYMBOL  TO  REDUCE  THE  RISK  OF 
PERSONAL INJURY AS WELL AS PROPERTY DAMAGE.

EXPLOSION  OR  RUPTURE  HAZARD

  A  relief 

valve  must  be  installed  to  prevent  pressure  in 

excess  of  local  code  requirement  or  maximum  working  pressure 
designated  in  the  Product  Manual,  whichever  is  less.    Do  not 
expose Product to freezing temperatures or temperatures in excess 
of 200° F.  Do not adjust the pre-charge or re-pressure this Product 
except for any adjustments required at the time of initial installation, 
especially  if  Product  corroded,  damaged  or  with  diminished 
integrity.    Adjustments  to  pre-charge  must  be  done  at  ambient 
temperature  only.    Failure  to  properly  size  the  Product  or  follow 
these instructions may result in excessive strain on the system lead 
to  Product  failure,  serious  or  fatal  personal  injury,  leakage  and/or 
property damage.

NOTE: 

  Inspect  for  shipping  damage  and  notify  freight  carrier  or 

store where purchased immediately if damage is present.  To avoid 
risk of personal injury and property damage, if the product appears 
to  be  malfunctioning  or  shows  signs  of  corrosion,  call  a  qualified 
professional  immediately.    Current  copies  of  the  Product  manual 
can be viewed at www.amtrol.com.  Use proper safety equipment 
when installing.

FAILURE  TO  PROPERLY  SEAL  WILL 
RESULT IN LOSS OF PRECHARGE CAUSING 

PRODUCT TO FAIL.
IMPORTANT GENERAL SAFETY INFORMATION - ADDITIONAL 
SPECIFIC  SAFETY  ALERTS  APPEAR  IN  THE  FOLLOWING 
INSTRUCTIONS.

PLEASE READ THE FOLLOWING INSTRUCTIONS CAREFULLY

Содержание G-5

Страница 1: ...Water Heater SAFETY TANK Water Heater SAFETY TANK Owner s Manual and Installation Instructions For Models G 5 G 5L G 12 G 12L NOW REQUIRED BY CODE IN MANY COUNTIES AND STATES...

Страница 2: ...ure satisfactory performance and prevent premature failure CALIFORNIA PROPOSITION 65 WARNING This product contains a chemical known by the State of California to cause cancer and to cause birth defect...

Страница 3: ...Tire pressure gauge Adjustable wrench Teflon tape or pipe sealant Model Volume Gallons Max Pressure psi Max Temp Air Cushion Pressure psi Diameter Height Tank Connection G 5 2 0 150 200 F 40 8 12 5 8...

Страница 4: ...sure relief valve setting As water is used Figure 3 the thermally expanded water is expelled from the tank back into the piping system by the compressed air cushion PRE INSTALLATION CHECK LIST 1 Remov...

Страница 5: ...pressure Tank comes charged to 40 psi Increase pressure as needed 4 Open hot waer faucet to relieve pressure Close faucet when pressure subsides flow stops Typical Completed Installation 2 Turn water...

Страница 6: ...ld assembly up to piping ensure that there is no interference with the wall ceiling or other appliances 11 Turn water supply main valve on and check for leaks 14 Turn water heater back to desired temp...

Страница 7: ...re is greater than 80 psi a pressure reducing valve is required 5 Relieve system pressure by opening a faucet near the water heater 3 Install a pressure reducing valve to reduce pressure to an approve...

Страница 8: ...Chauffe eau R SERVOIR DE S CURIT Chauffe eau R SERVOIR DE S CURIT Manuel du propri taire et notice d installation Pour les mod les G 5 G 5L G 12 G 12L...

Страница 9: ......

Страница 10: ...PORTANT Pour votre protection veuillez lire ces importantes directives d installation Le r servori de s curit de chauffe eau devrait tre utilis dans tout syst me de chauffe eau ferm La proc dure d ins...

Страница 11: ...ourn e dans la tuyauterie par le matelas d air comprim PRE INSTALLATION CHECK LIST 1 Retire le r servoir de la bo te et v rifier s il y a des dommages Si le r servoir est endommag le retourner imm dia...

Страница 12: ...de proc der 4 Ouvrir le robinet d eau chaude pour lib rer la pression Fermer le robinet lorque la pression baisse l eau arr t de couler Installation type termin e 2 R gler le chauffe eau a la temp rat...

Страница 13: ...e la tuyauterie s assure qu il n obstrue pas le mur le plafond ou tout autre appareil 11 Ouvrir le robinet principal d alimentation en eau et v rifier s il y a des fuites 14 R gler de nouveau le chauf...

Страница 14: ...ermer le robinet principal d alimentation en eau Installation type termin e 2 Enlever le chapeau d air et mesurer la pression dans le r servoir Si la pression est sup rieure 80 psi il faut installer u...

Страница 15: ...Calentador de agua TANQUE DE SEGURIDAD Calentador de agua TANQUE DE SEGURIDAD Manuel del Propietario e Insturcciones de Instalaci n Para los modelos G 5 G 5L G 12 G 12L...

Страница 16: ......

Страница 17: ...TE Para su protecci n por favor leer estos requisitos importantes de instalaci n El tanque de seguridad del calentador de agua debe ser usado en todo sistema cerrado de calentamiento de agua La instal...

Страница 18: ...da del tanque de regreso al sistema de tuber as por el colch n de aire comprimido LISTA DE COMPROBACION PREVIA A LA INSTALACION 1 Retire el tanque de la caja e inspeccion si hay da os Si hay da os evi...

Страница 19: ...ceder 4 Albra el grifo de agua caliente para aliviar la presi n Cierre el grifo cuando la presi n disminuye no sale agua Instalaci n t pica terminada 2 Regule el calentador de agua a la temperatura m...

Страница 20: ...sobre el tubo asegur ndos de que no haya interferencia con la pared techo u otros artefactos 11 Abra la v lvula principal de suminisro de agua y compruebe si hay fugas 14 Vuelva a colcar el calentado...

Страница 21: ...a presi n previa de carga cierre la v lvula principal de suministro de agua Instalaci n t pica terminada 2 Retire la tapa del v stago para aire y mida la presi n en el tanque Si es mayor de 80 psi se...

Страница 22: ......

Страница 23: ......

Страница 24: ...905 Hickory Lane Mansfield Ohio 44905 Form No 9015 478 04 08...

Отзывы: