MANUAL REGENERATION

NOTE:

 For softeners, if brine tank does 

not contain salt, fill with salt and wait 

at least two hours before regeneration . 

If you need to initiate a manual 

regeneration, either immediately, or the 

same night at the preprogrammed time 

for regeneration (typically 2:00 AM), 

complete the following steps . 

For Immediate Regeneration:

 

Press and hold 

regen

 until valve motor  starts (typically 3 seconds) . 

For Regeneration the same night:

 

Press and release 

regen

 (notice that flashing “REGEN TODAY” 

appears) .

ERROR

If the display toggles between “Error” 

and an error code (i .e . a number), call 

a service technician and report the 

error code .

BYPASS VALVE OPERATION

To shut off water to the system, position arrow handles as shown in 

the bypass operation diagram below . If your valve doesn’t look like 

the diagram below, contact your service technician for instructions 

on how to shut off water .

REGEN TODAY

MON

GPM

2:40

8

PM

REGEN TODAY 

and 

TIME OF DAY 

will flash alternately if a regeneration 
is expected tonight.

NORMAL OPERATION

BYPASS OPERATION

ADJUST HARDNESS, DAYS BETWEEN REGENERATION, TIME OF REGENERATION AND ALARM BUZZER

For initial set-up or to make adjustments, please complete the following steps .

QUICK REFERENCE GUIDE

GENERAL OPERATION

When the system is operating, one of four displays will be shown: 

time of day/gpm, flow rate, capacity remaining or days to a regen . 

Pressing 

next

 will toggle between the three choices .

TO SET TIME OF DAY

In the event of a prolonged power outage, time of day flashes, 

indicating that this needs to be reset . All other information will be 

stored in memory no matter how long the power outage .

1 .  Accessed by pressing 

set

 

clock

2 .  Adjust hours with 

+

 and 

 buttons, AM/PM toggles at 12

3 . Press 

next

4 .  Adjust minutes with 

+

 and 

 buttons

5 . Press 

next

6 . Adjust current day with 

+

 and 

 buttons

7 .   Press 

next

 to complete and return to normal operation

1 .  Accessed by pressing 

next

 and 

+

 button simultaneously

2 .  Adjust hardness using 

+

 and 

 buttons

3 . Press 

next

4 .  Adjust days between regenerations using 

+

 and 

 buttons

5 . Press 

next

6 .  Adjust time of regeneration hour with 

+

 and 

 buttons, 

AM/PM toggles at 12 .

7 . Press 

next

8 .  Adjust time of regeneration minutes with 

+

 and 

 buttons

9 . Press 

next

10 .  Turn alarm buzzer ON or OFF with 

+

 and 

 buttons

11 .   Press 

next

 to complete and return to normal operation .

TIME OF DAY

MON

GPM

2:40

8

PM

FLOW RATE

GPM

8.0

CAPACITY REMAINING

GPM

GAL

1600

8

DAYS TO A REGEN

GPM

3

8

TIME OF DAY

MON

GPM

2:40

8

PM

FLOW RATE

GPM

8.0

CAPACITY REMAINING

GPM

GAL

1600

8

DAYS TO A REGEN

GPM

3

8

CURRENT DAY

SET

MON

TIME

MINUTES

SET

TIME

HOUR

SET

2:00

AM

CURRENT DAY

SET

MON

TIME

MINUTES

SET

TIME

HOUR

SET

2:00

AM

ALARM BUZZER

SET

ON

REGEN TIME MINUTES

SET

2:00

AM

REGEN TIME HOUR

SET

2:00

AM

DAYS BETWEEN REGEN

SET

6

WATER HARDNESS

SET

20

GR

ALARM BUZZER

SET

ON

REGEN TIME MINUTES

SET

2:00

AM

REGEN TIME HOUR

SET

2:00

AM

DAYS BETWEEN REGEN

SET

6

WATER HARDNESS

SET

20

GR

© 2011 Water-Right, Inc.   All rights reserved.
LIT-SAN + MAN   05/17

Содержание Sanitizer Plus Series

Страница 1: ...Sanitizer Plus Series Water Conditioners...

Страница 2: ...tions and notes before installing This manual should be kept for future reference If you have any questions regarding your water conditioner contact your local dealer or Water Right at the following W...

Страница 3: ...g operation the normal user display is time of day and gallons per minute Flow Rate Capacity Remaining and Days to a Regeneration are optional displays but are not normally used Each of these can be v...

Страница 4: ...regeneration water to the unit while also providing untreated water to the distribution system Fig 1 2 BYPASS POSITION The inlet and outlet handles point to the center of the bypass The system is iso...

Страница 5: ...STALLATION INSTALLATION 1 The distance between the drain and the water conditioner should be as short as possible 2 Since salt must be added periodically to the brine tank it should be in an easily ac...

Страница 6: ...this could cause interior damage to the flow control Install a 1 2 I D flexible plastic tube to the Drain Line Assembly or discard the tubing nut and use the 3 4 NPT fitting for rigid pipe recommende...

Страница 7: ...wever an overflow line connection will direct the overflow to the drain instead of spilling on the floor where it could cause considerable damage This fitting is an elbow on the side of the brine tank...

Страница 8: ...the remaining time in this step is counting down Since the regenerant tank was already filled in Step 1 press regen again and the display will read SOFTENING 240 During a full regeneration this will b...

Страница 9: ...ns were not used to call for a regeneration Set Day Override using or buttons 6 is recommended set number of days between regeneration 1 to 28 or set to OFF NOTE This valve has the capability of regen...

Страница 10: ...or buttons Press next to exit installer programming STEP 7 DISPLAY BACKLIGHT The manufacturer has factory set ON as the default Turn the light OFF or ON using or buttons OFF will turn display backligh...

Страница 11: ...reaches the proper level Once this position is complete you will notice a 240 Minute 4 hours SOFTENING position This 4 hour window allows the salt to dissolve and achieve proper brine strength During...

Страница 12: ...ice 6 ERROR MESSAGE If the word ERROR and a number are alternately flashing on the display record the number and contact your dealer for help This indicates that the control valve was not able to func...

Страница 13: ...13 This page left intentionally blank...

Страница 14: ...stalled meter turbine C Remove meter and check for rotation or foreign material D Meter wire not installed securely into three pin connector D Verify meter cable wires are installed securely into thr...

Страница 15: ...el in regenerant tank G Check refill setting in programming Check refill flow control for restrictions or debris and clean or replace H Damaged seal stack assembly H Replace seal stack assembly I Cont...

Страница 16: ...ze software with piston position or disconnect power supply from PC board for 5 seconds and then reconnect B PC board not properly snapped into drive bracket B Properly snap PC board into drive bracke...

Страница 17: ...on A Drive bracket not snapped in properly and out enough that reduction gears and drive gear do not interface A Snap drive bracket in properly then Press NEXT and REGEN buttons for 3 seconds to resyn...

Страница 18: ...ect power supply from PC board for 5 seconds and then reconnect 20 Err 109 A Invalid motor state detected A Replace PC board 21 Err 201 A Invalid regeneration cycle step detected A Replace PC board 22...

Страница 19: ...Black cover 1 CV3540 WS A Gray cover 1 2 CV3107 1 Motor 1 3 CV3106 1 Drive bracket spring clip 1 4 CV3554WS PC board Sanitizer 1 5 CV3110 Drive gear 12 x 36 3 6 CV3109 Drive gear cover 1 CV3526 Trans...

Страница 20: ...assembly upflow 1 CV3407 1 25 piston assembly downflow 1 5 CV3174 Regenerant piston 1 6 CV3180 O ring 337 1 7 CV3105 O ring 215 1 8 CV3556 Screw 1 4 20x1 1 2 18 8SS 1 9 CCI 00318337 Nut 1 4 20 HEX 18...

Страница 21: ...t 1 quick connect 2 2 CV3150 Split ring 2 3 CV3105 O ring 215 2 4 CV3145 Bypass rotor 1 2 5 CV3146 Bypass cap 2 6 CV3147 Bypass handle 2 7 CV3148 Bypass rotor seal retainer 2 8 CV3152 O ring 135 2 9 C...

Страница 22: ...assembly yellow CV3010 1H H injector assembly green CV3010 1I I injector assembly orange CV3010 1J J injector assembly light blue CV3010 1K K injector assembly light green not shown CV3170 O ring 011...

Страница 23: ...lbow CV3162 013 1 3 DLFC for 3 4 elbow CV3162 017 1 7 DLFC for 3 4 elbow CV3162 022 2 2 DLFC for 3 4 elbow CV3162 027 2 7 DLFC for 3 4 elbow CV3162 032 3 2 DLFC for 3 4 elbow CV3162 042 4 2 DLFC for 3...

Страница 24: ...tems 3 4 1 3 CV3118 01 Turbine assembly 1 4 CV3105 O ring 215 1 5 CV3003 01 Meter plug assembly 1 REPLACEMENT PARTS Although no tools are necessary to assemble or disassemble the valve the Service Wre...

Страница 25: ...CH1030 36S 4 x 36 slotted brine well 18 x 40 24 x 40 BT s 1 5 CH1018 2 piece overflow set 1 6 CH4500 48 474 air check assembly 1 2 x 48 1 7 CH4620 474 float assembly 7 1 8 CH4600 50 474 safety brine v...

Страница 26: ...51 Nut 1 quick connect 2 2 CV3150 Split ring 2 3 CV3105 O ring 215 2 4 CV3188 Fitting 2 3 4 BRASS SWEAT Item No Part No Description Qty CV3007 03 3 4 brass sweat assembly 2 1 CV3151 Nut 1 quick connec...

Страница 27: ...3375 Fitting 2 1 BRASS SHARK BITE Item No Part No Description Qty CV3007 13 1 brass Shark Bite assembly 2 1 CV3151 Nut 1 quick connect 2 2 CV3150 Split ring 2 3 CV3105 O ring 215 2 4 CV3629 Fitting 2...

Страница 28: ...300 9 5 11 100 3 2 22 900 6 1 28 200 9 3 Amount of Media Cu Ft 1 0 1 5 2 5 1 0 1 5 2 5 Maximum Water Hardness GPG 20 30 40 40 60 80 2Maximum Iron and Manganese PPM 8 0 10 0 15 0 8 0 10 0 15 0 3Minimum...

Страница 29: ...or replace the part or component at its expense and return part freight collect The above provisions of the warranty are valid as long as the unit is connected in compliance with local plumbing codes...

Страница 30: ...ate capacity remaining or days to a regen Pressing next will toggle between the three choices TO SET TIME OF DAY In the event of a prolonged power outage time of day flashes indicating that this needs...

Отзывы: