background image

4

 NORMAL 

OPERATION 

POSITION

 BYPASS POSITION

 DIAGNOSTIC 

POSITION

 SHUT OFF 

POSITION

FIGURE 1

FIGURE 3

FIGURE 2

FIGURE 4

BYPASS VALVE

The bypass valve is typically used to isolate the control valve from the plumbing system’s water pressure in order to perform control 

valve repairs or maintenance. The 1” full flow bypass valve incorporates four positions, including a diagnostic position that allows 

a service technician to have pressure to test a system while providing untreated bypass water to the building. Be sure to install 

bypass valve onto main control valve, before beginning plumbing. Or, make provisions in the plumbing system for a bypass. The 

bypass body and rotors are glass-filled Noryl

®

 and the nuts and caps are glass-filled polypropylene. All seals are self-lubricating 

EPDM to help prevent valve seizing after long periods of non-use. Internal “O” Rings can easily be replaced if service is required.

The bypass consists of two interchangeable plug valves that are operated independently by red arrow shaped handles. The 

handles identify the direction of flow. The plug valves enable the bypass valve to operate in four positions.
1.   

NORMAL OPERATION POSITION:

 The inlet and outlet handles point in the direction of flow indicated by the engraved 

arrows on the control valve. Water flows through the control valve for normal operation of a water softener or filter. During 

the regeneration cycle this position provides regeneration water to the unit, while also providing untreated water to the 

distribution system 

(Fig. 1)

.

2.   

BYPASS POSITION: 

The inlet and outlet handles point to the center of the bypass. The system is isolated from the water 

pressure in the plumbing system. Untreated water is supplied to the building 

(Fig. 2)

.

3.   

DIAGNOSTIC POSITION:

 The inlet handle points toward the control valve and the outlet handle points to the center 

of bypass valve. Untreated supply water is allowed to flow to the system and to the building, while not allowing water to 

exit from the system to the building (

Fig. 3)

. This allows the service technician to test the unit and perform other functions 

without disrupting the water going to the building.

     

NOTE:

 The system must be rinsed before returning the bypass valve to the normal position.

4.   

SHUT OFF POSITION:

 The inlet handle points to the center of the bypass valve and the outlet handle points away from 

the control valve. The water is shut off to the building. The water treatment system will depressurize upon opening a tap in 

the building. A negative pressure in the building combined with the unit being in regeneration could cause a siphoning to 

the building. If water is available on the outlet side of the unit, it is an indication of water bypassing the system 

(Fig. 4)

 

(i.e. a plumbing cross-connection somewhere in the building).

Содержание IMP-844

Страница 1: ...Impression Plus Series Metered Water Softeners For Certified Models IMP 844 IMP 948 IMP 1044 IMP 1054 IMP 1248 IMP 1354 Certified Cabinet Models IMPC 835 IMPC 935 IMPC 1035...

Страница 2: ...erstand the cautions and notes before installing This manual should be kept for future reference If you have any questions regarding your water softener contact your local dealer or Water Right at the...

Страница 3: ...Remaining and Days to a Regeneration are optional displays but are not normally used Each of these can be viewed by pressing NEXT to scroll through them When stepping through any programming if no but...

Страница 4: ...r flows through the control valve for normal operation of a water softener or filter During the regeneration cycle this position provides regeneration water to the unit while also providing untreated...

Страница 5: ...nd the water conditioner should be as short as possible see step 8 2 Since salt must be added periodically to the brine tank it should be in an easily accessible location 3 It is NOT recommended to in...

Страница 6: ...this could cause interior damage to the flow control Install a 1 2 I D flexible plastic tube to the Drain Line Assembly or discard the tubing nut and use the 3 4 NPT fitting for rigid pipe recommende...

Страница 7: ...tion however an overflow line connection will direct the overflow to the drain instead of spilling on the floor where it could cause considerable damage This fitting is an elbow on the side of the bri...

Страница 8: ...increments NOTE If a resin media is used in the softener increase the grains per gallon if soluble iron is present 1 ppm 4 gpg This display will show GALLONS AVAILABLE BETWEEN REGENERATIONS if FILTER...

Страница 9: ...the inlet handle of the bypass valve very slightly allowing water to fill the tank slowly in order to expel air CAUTION If water flows too rapidly media will be lost to the drain 3 When the water is f...

Страница 10: ...ed or when the system has been operated without salt To initiate a manual regeneration at the next preset regeneration time press and release REGEN The words REGEN TODAY will flash on the display to i...

Страница 11: ...operating displays and maintenance If these procedures do not remedy the problem please consult the installing dealer for service 5 ERROR MESSAGE If the word ERROR appears and flashes alternately with...

Страница 12: ...Restricted stalled meter turbine C Remove meter and check for rotation or foreign material D Meter wire not installed securely into three pin connector D Verify meter cable wires are installed secure...

Страница 13: ...G Check refill setting in programming Check refill flow control for restrictions or debris and clean or replace H Damaged seal stack assembly H Replace seal stack assembly I Control valve body type a...

Страница 14: ...ston position or disconnect power supply from PC board for 5 seconds and then reconnect B PC board not properly snapped into drive bracket B Properly snap PC board into drive bracket and then Press NE...

Страница 15: ...seconds to resynchronize software with piston position or disconnect power supply from PC board for 5 seconds and then reconnect Then reprogram valve to proper setting B MAV NHBP motor wire not conne...

Страница 16: ...uzzer will activate and the screen will display the error A Check for low flow leak Press NEXT and REGEN buttons for 3 seconds to resynchronize software with piston position or disconnect power supply...

Страница 17: ...17 This page left intentionally blank...

Страница 18: ...lack Impression Plus cover 1 CV3540P W A Gray Impression Plus cover 1 2 CV3107 1 Motor 1 3 CV3002A Drive bracket spring clip Includes 5 6 1 4 CV3579WI PC board Impression 1 CV3813WP PC board Impressio...

Страница 19: ...nerant piston 1 6 CV3180 O ring 337 1 7 CV3105 O ring 215 1 8 CV3556 Screw 1 4 20x1 1 2 18 8SS 1 9 CCI 00318337 Nut 1 4 20 HEX 18 8SS 1 10 CV3016 QC2 clamp assembly includes screw nut 1 11 CV3452 O ri...

Страница 20: ...PARTS 2 4 1 3 BRINE ELBOW ASSEMBLY Item No Part No Description Qty 1 CV3195 01 Refill port plug assembly 1 2 CH4615 Elbow locking clip 1 3 CV4144 3 8 Elbow Parker fitting 1 4 CV3163 O ring 019 1 Altho...

Страница 21: ...embly BLUE CV3010 1G G injector assembly YELLOW CV3010 1H H injector assembly GREEN CV3010 1I I injector assembly ORANGE CV3010 1J J injector assembly LIGHT BLUE CV3010 1K K injector assembly LIGHT GR...

Страница 22: ...n 1 Strt No Sil 1 REPLACEMENT PARTS Water flow Proper DLFC orientation directs water flow towards the washer face with rounded edge DRAIN LINE ASSEMBLY 3 4 Item No Part No Description Qty 1 CH4615 Elb...

Страница 23: ...1030 36S 4 x 36 slotted brine well 18 x 40 24 x 40 BT s 1 5 CH1018 2 piece overflow set 1 6 CH4500 48 474 air check assembly 1 2 x 48 1 7 CH4620 474 float assembly 7 1 8 CH4600 50 474 safety brine val...

Страница 24: ...AND BRINE TANK Item No Part No Description Qty 1 CJ2TCWS HEH Top Assembly Light Gray Dark Gray 1 2 CJ2B35E Bottom Assembly Light Gray with 474 Brine Assembly 1 Not shown CH4850 34 625 Brine Well with...

Страница 25: ...25 This page left intentionally blank...

Страница 26: ...CV3105 O ring 215 2 4 CV3188 Fitting 2 3 4 BRASS SWEAT Item No Part No Description Qty CV3007 03 3 4 brass sweat assembly 2 1 CV3151 Nut 1 quick connect 2 2 CV3150 Split ring 2 3 CV3105 O ring 215 2...

Страница 27: ...2 3 CV3105 O ring 215 2 4 CV3629 Fitting 2 3 4 BRASS SHARK BITE Item No Part No Description Qty CV3007 12 3 4 brass Shark Bite assembly 2 1 CV3151 Nut 1 quick connect 2 2 CV3150 Split ring 2 3 CV3105...

Страница 28: ...MODEL IMPC SPECIFICATIONS MODEL IMP 844 IMP 948 IMP 1044 IMP 1054 IMP 1248 IMP 1354 Rated Softener Capacity Grains Lbs Salt Minimum 13 700 3 4 18 200 4 5 18 200 4 5 27 600 7 0 36 400 9 0 45 800 11 5 M...

Страница 29: ...replace the part or component at its expense and return part freight collect The above provisions of the warranty are valid as long as the unit is connected in compliance with local plumbing codes an...

Страница 30: ...stored in memory no matter how long the power outage 1 Accessed by pressing SET CLOCK 2 Adjust hours with and buttons AM PM toggles at 12 3 Press NEXT 4 Adjust minutes with and buttons 5 Press NEXT 6...

Страница 31: ...31 This page left intentionally blank...

Страница 32: ...1900 Prospect Court Appleton WI 54914 Phone 920 739 9401 Fax 920 739 9406 2018 Water Right Inc All rights reserved MAN IMP CERT RevA0818...

Отзывы: