 PROBLEM 

CAUSE 

CORRECTION 

 1.  No display on 

PC board

 A. No power at electric outlet

 A. Repair outlet or use working outlet

 B.  Control valve power adapter not plugged into 

outlet or power cord end not connected to PC 

board connection

 B.  Plug power adapter into outlet or connect 

power cord end to PC board connection

 C. Improper power supply

 C.  Verify proper voltage is being delivered to 

PC board

 D. Defective power adapter

 D. Replace power adapter

 E. Defective PC board

 E. Replace PC board

 F. Depleted battery

 F. See Operating Display and Maintenance section

 2.   PC board does not 

display correct time 

of day

 A.  Power adapter plugged into electric outlet 

controlled by light switch

 A. Use uninterrupted outlet

 B. Tripped breaker switch and/or tripped GFI

 B.  Reset breaker switch and/or GFI switch

 C. Power outage 

 C.  Reset time of day. If PC board has battery 

back up present the battery may be depleted. 

See front cover and drive assembly drawing 

for instructions.

 D. Defective PC board

 D. Replace PC board

 3.   Display does not 

indicate that water is 

flowing. Refer to user 

instructions for how the 

display indicates water 

is flowing.

 A. Bypass valve in bypass position

 A.   Turn bypass handles to place bypass in 

service position

 B.  Meter is not connected to meter connection on 

PC board

  B.    Connect meter to three pin connection labeled 

METER on PC board

 C. Restricted/stalled meter turbine

 C.  Remove meter and check for rotation or 

foreign material

 D.  Meter wire not installed securely into three 

pin connector

 D.  Verify meter cable wires are installed securely 

into three pin connector labeled METER

 E. Defective meter

 E. Replace meter

 F. Defective PC board

 F. Replace PC board

 4.  Control valve 

regenerates at wrong 

time of day

 A. Power outage

 A.  Reset time of day. If PC board has battery 

back up present the battery may be depleted. 

See front cover and drive assembly drawing 

for instructions.

 B. Time of day not set correctly

 B. Reset to correct time of day

 C. Time of regeneration set incorrectly

 C. Reset regeneration time

 D.  Control valve set at “on 0” (immediate 

regeneration)

 D.  Check programming setting and reset to 

NORMAL (for a delayed regen time)

 E.  Control valve set at “ on 0” 

(delayed and/or immediate)

 E.  Check programming setting and reset to 

NORMAL (for a delayed regen time)

  5.  Time of day flashes on 

and off

 A. Power outage

 A.  Reset time of day. If PC board has battery 

back up present the battery may be depleted. 

See front cover and drive assembly drawing 

for instructions.

 6.   Control valve does not 

regenerate automatically 

when the correct button(s) 

is depressed and held. 

For timeclock valves the 

buttons are 

▲ 

For all other valves the 

button is REGEN.

 A. Broken drive gear or drive cap assembly

 A. Replace drive gear or drive cap assembly

 B. Broken piston rod

 B. Replace piston rod

 C. Defective PC board

 C. Defective PC board

 D. Cover installed incorrectly

 D. Reinstall cover

TROUBLESHOOTING GUIDE

Содержание IMP-844

Страница 1: ...Impression Plus Series Metered Water Softeners For Certified Models IMP 844 IMP 948 IMP 1044 IMP 1054 IMP 1248 IMP 1354 Certified Cabinet Models IMPC 835 IMPC 935 IMPC 1035...

Страница 2: ...erstand the cautions and notes before installing This manual should be kept for future reference If you have any questions regarding your water softener contact your local dealer or Water Right at the...

Страница 3: ...Remaining and Days to a Regeneration are optional displays but are not normally used Each of these can be viewed by pressing NEXT to scroll through them When stepping through any programming if no but...

Страница 4: ...r flows through the control valve for normal operation of a water softener or filter During the regeneration cycle this position provides regeneration water to the unit while also providing untreated...

Страница 5: ...nd the water conditioner should be as short as possible see step 8 2 Since salt must be added periodically to the brine tank it should be in an easily accessible location 3 It is NOT recommended to in...

Страница 6: ...this could cause interior damage to the flow control Install a 1 2 I D flexible plastic tube to the Drain Line Assembly or discard the tubing nut and use the 3 4 NPT fitting for rigid pipe recommende...

Страница 7: ...tion however an overflow line connection will direct the overflow to the drain instead of spilling on the floor where it could cause considerable damage This fitting is an elbow on the side of the bri...

Страница 8: ...increments NOTE If a resin media is used in the softener increase the grains per gallon if soluble iron is present 1 ppm 4 gpg This display will show GALLONS AVAILABLE BETWEEN REGENERATIONS if FILTER...

Страница 9: ...the inlet handle of the bypass valve very slightly allowing water to fill the tank slowly in order to expel air CAUTION If water flows too rapidly media will be lost to the drain 3 When the water is f...

Страница 10: ...ed or when the system has been operated without salt To initiate a manual regeneration at the next preset regeneration time press and release REGEN The words REGEN TODAY will flash on the display to i...

Страница 11: ...operating displays and maintenance If these procedures do not remedy the problem please consult the installing dealer for service 5 ERROR MESSAGE If the word ERROR appears and flashes alternately with...

Страница 12: ...Restricted stalled meter turbine C Remove meter and check for rotation or foreign material D Meter wire not installed securely into three pin connector D Verify meter cable wires are installed secure...

Страница 13: ...G Check refill setting in programming Check refill flow control for restrictions or debris and clean or replace H Damaged seal stack assembly H Replace seal stack assembly I Control valve body type a...

Страница 14: ...ston position or disconnect power supply from PC board for 5 seconds and then reconnect B PC board not properly snapped into drive bracket B Properly snap PC board into drive bracket and then Press NE...

Страница 15: ...seconds to resynchronize software with piston position or disconnect power supply from PC board for 5 seconds and then reconnect Then reprogram valve to proper setting B MAV NHBP motor wire not conne...

Страница 16: ...uzzer will activate and the screen will display the error A Check for low flow leak Press NEXT and REGEN buttons for 3 seconds to resynchronize software with piston position or disconnect power supply...

Страница 17: ...17 This page left intentionally blank...

Страница 18: ...lack Impression Plus cover 1 CV3540P W A Gray Impression Plus cover 1 2 CV3107 1 Motor 1 3 CV3002A Drive bracket spring clip Includes 5 6 1 4 CV3579WI PC board Impression 1 CV3813WP PC board Impressio...

Страница 19: ...nerant piston 1 6 CV3180 O ring 337 1 7 CV3105 O ring 215 1 8 CV3556 Screw 1 4 20x1 1 2 18 8SS 1 9 CCI 00318337 Nut 1 4 20 HEX 18 8SS 1 10 CV3016 QC2 clamp assembly includes screw nut 1 11 CV3452 O ri...

Страница 20: ...PARTS 2 4 1 3 BRINE ELBOW ASSEMBLY Item No Part No Description Qty 1 CV3195 01 Refill port plug assembly 1 2 CH4615 Elbow locking clip 1 3 CV4144 3 8 Elbow Parker fitting 1 4 CV3163 O ring 019 1 Altho...

Страница 21: ...embly BLUE CV3010 1G G injector assembly YELLOW CV3010 1H H injector assembly GREEN CV3010 1I I injector assembly ORANGE CV3010 1J J injector assembly LIGHT BLUE CV3010 1K K injector assembly LIGHT GR...

Страница 22: ...n 1 Strt No Sil 1 REPLACEMENT PARTS Water flow Proper DLFC orientation directs water flow towards the washer face with rounded edge DRAIN LINE ASSEMBLY 3 4 Item No Part No Description Qty 1 CH4615 Elb...

Страница 23: ...1030 36S 4 x 36 slotted brine well 18 x 40 24 x 40 BT s 1 5 CH1018 2 piece overflow set 1 6 CH4500 48 474 air check assembly 1 2 x 48 1 7 CH4620 474 float assembly 7 1 8 CH4600 50 474 safety brine val...

Страница 24: ...AND BRINE TANK Item No Part No Description Qty 1 CJ2TCWS HEH Top Assembly Light Gray Dark Gray 1 2 CJ2B35E Bottom Assembly Light Gray with 474 Brine Assembly 1 Not shown CH4850 34 625 Brine Well with...

Страница 25: ...25 This page left intentionally blank...

Страница 26: ...CV3105 O ring 215 2 4 CV3188 Fitting 2 3 4 BRASS SWEAT Item No Part No Description Qty CV3007 03 3 4 brass sweat assembly 2 1 CV3151 Nut 1 quick connect 2 2 CV3150 Split ring 2 3 CV3105 O ring 215 2...

Страница 27: ...2 3 CV3105 O ring 215 2 4 CV3629 Fitting 2 3 4 BRASS SHARK BITE Item No Part No Description Qty CV3007 12 3 4 brass Shark Bite assembly 2 1 CV3151 Nut 1 quick connect 2 2 CV3150 Split ring 2 3 CV3105...

Страница 28: ...MODEL IMPC SPECIFICATIONS MODEL IMP 844 IMP 948 IMP 1044 IMP 1054 IMP 1248 IMP 1354 Rated Softener Capacity Grains Lbs Salt Minimum 13 700 3 4 18 200 4 5 18 200 4 5 27 600 7 0 36 400 9 0 45 800 11 5 M...

Страница 29: ...replace the part or component at its expense and return part freight collect The above provisions of the warranty are valid as long as the unit is connected in compliance with local plumbing codes an...

Страница 30: ...stored in memory no matter how long the power outage 1 Accessed by pressing SET CLOCK 2 Adjust hours with and buttons AM PM toggles at 12 3 Press NEXT 4 Adjust minutes with and buttons 5 Press NEXT 6...

Страница 31: ...31 This page left intentionally blank...

Страница 32: ...1900 Prospect Court Appleton WI 54914 Phone 920 739 9401 Fax 920 739 9406 2018 Water Right Inc All rights reserved MAN IMP CERT RevA0818...

Отзывы: