TROUBLESHOOTING - CLP
PROBLEM
POSSIBLE CAUSE
SOLUTION
NO FLOW OF WATER
INTO THE CLP
Control switch not in "ON" position
Turn switch to "ON" position.
Power not turned "ON" at breaker box
Turn "ON" power at breaker box.
Float in sump in down position
Add water to pump.
Debris in sump impeller
Unplug pump and remove from container.
Flow valve closed
Open valve.
Dirt lodged in control valve
Clean as needed.
Frozen water in lines or valves
Thaw out with warm water.
WATER FLOWING
OVER CLP
Tank not level
Level tank.
Water coming into the CLP faster
than 5 - 30 gpm
Adjust flow control valve.
Discharge line plugged
Remove obstruction.
Pump not wired in
Wire in pump.