background image

8

OPERATING YOUR THERMOSTAT

Choose the Fan Setting (Auto or On or Prog)

Fan 

Auto is the most commonly selected setting and runs the 

fan only when the heating or cooling system is on .
Fan 

On selection runs the fan continuously for increased air 

circulation or to allow additional air cleaning .
Fan 

Prog will run the fan when the heating or cooling system 

is on . In addition, when the thermostat has not called for heat 
or cool for more than 60 minutes, it will begin to cycle the fan 
for 10 minutes on and 20 minutes off to improve indoor air 
quality . This is the Comfort Circulating Fan Feature .

Choose the System Setting

(Cool, Off, Heat, Emer, Auto)

Press the SYSTEM button to select:
Heat: Thermostat controls only the heating system .
Off: Heating and Cooling systems are off .
Cool: Thermostat controls only the cooling system .
Auto: Auto Changeover is used in areas where both heating 
and cooling may be required on the same day . 

AUTO allows 

the thermostat to automatically select heating or cooling 
depending on the indoor temperature and the selected heat 
and cool temperatures . When using 

AUTO, be sure to set the 

Cooling temperatures more than 1° Fahrenheit higher than 
the heating temperature .
Emer: Thermostat controls only Aux heat .

Manual Operation for

Non-Programmable Mode

Press the SYSTEM button to select Heat or Cool and use
the 

 or   buttons to adjust the temperature to your

desired setting . After selecting your desired settings you can
also press the SYSTEM button to select 

AUTO to allow

the thermostat to automatically change between Heat and
Cool .

Manual Operation (Bypassing the Program)

Programmable Mode

Press 

 or 

 and the HOLD button and adjust the tempera-

ture wherever you like . This will override the program . The 
HOLD feature bypasses the program and allows you to adjust 
the temperature manually, as needed . Whatever temperature 
you set in 

HOLD will be maintained 24 hours a day, until you 

manually change the temperature or press 

Run Schedule to 

cancel 

HOLD and resume the programmed schedule .

Program Override (Temporary Override)

Press 

 or 

 buttons to adjust the temperature . This will 

override the temperature setting for a (default) four hour over-
ride period . The override period can be shortened by pressing 

 or lengthened by pressing   . Program Override period 

can range from 15 minutes to 7 days .
Example: If you turn up the heat during the morning program, 
it will be automatically lowered later, when the temporary hold 
period ends . To cancel the temporary setting at any time and 
return to the program, press 

Run Schedule .

If the SYSTEM button is pressed to select 

AUTO the

thermostat will change to Heat or Cool, whichever ran last . If
it switches to heat but you want cool, or it changes to cool but 
you want heat, press both 

 or 

 buttons simultaneously to 

change to the other mode .

IMPORTANT!

PROGRAMMING 

Set Current Time and Day

1)  Press Menu key to enter installer menu . Then press
 

Set Time once to indicate hour & A or P designation in

 

clock display .

2)  Press and hold either the   or   touch key until you
 

reach the correct hour and A or P designation .

3)  Press Set Time again to display minutes only in clock
 

display .

4)  Press and hold either the   or   touch keys until you 
 

reach the correct minutes .

5)  Press Set Time once again to display year .
6)  Press and hold either the   or   touch key until you
 

reach the correct year .

7)  Press Set Time once again to display month .
8)  Press and hold either the   or   touch key until you
 

reach the correct month .

9)  Press Set Time once again to display date of the month
 

along with day of the week at top row (which is auto-

 

matic) .

10)  Press and hold either the   or   touch key until you
 

reach the correct day of the month and day of the week

 

is automatically calculated and displayed at the top row .

11)  Press Run Schedule once; now the display will show the
 

correct time and room temperature .

Automatic Daylight Saving Calculation

The Real Time Clock will adjust automatically for daylight sav-
ings time, in the following manner:
Increment one hour at 2 AM on the second Sunday of March 
and decrement one hour at 2 AM on the first Sunday of No-
vember . (New DST effective 2007) .
The daylight saving feature can be enabled or disabled in 
installer configuration menu . Default is 

dS On (enabled) .

After entering installer configuration mode, momentarily
press 

 or 

 touch key until the display indicates

 dS (in

actual temperature digits) and 

On (default – in clock digits) .

 and   keys will toggle display and operation from On to 

OFF .

Содержание TP32W03

Страница 1: ...at contains mercury Mercury and products containing mercury must not be discarded in household trash Do not touch any spilled mercury Wearing non absorbent gloves clean up any spilled mercury and plac...

Страница 2: ...thermostat one at a time Do not let wires fall back into the wall Installing New Thermostat 1 Pull the thermostat body off the thermostat base Forcing or prying on the thermostat will cause damage to...

Страница 3: ...C W E Jumper G C W2 Jumper No Output 1st Stage Heat Cool Com pressor Blower Circula tor Fan Energiz ed on call for Heat or Cool 24 VAC Hot Cool DC supply voltage to re mote Temp erature Sensor Remote...

Страница 4: ...e 12 Call For Service indicates a fault in the heating cooling system It does not indicate a fault in the thermostat Programming and Configuration Items Figure 3 Programming Configuration Items 13 Sys...

Страница 5: ...I Selects Backlight Intensity 13 13 11 0 4 LO to 4 HI Selects Adjustable Ambient Temperature Display range 4 LO to 4 HI 14 14 12 F C Selects F C Display temperature units in Fahrenheit or Celsius 15 1...

Страница 6: ...and 98 F by pressing the or key The temperature limit icon will be displayed to the left of your setpoint temperature when using this feature The temperature limit icon will flash if an attempt is mad...

Страница 7: ...IGURATION MENU 2 C or more above the actual temperature using the second stage will energize immediately With FA OFF second stage will not energize until the setpoint tempera ture is 1 F or more above...

Страница 8: ...ure setting for a default four hour over ride period The override period can be shortened by pressing or lengthened by pressing Program Override period can range from 15 minutes to 7 days Example If y...

Страница 9: ...n the fan on for 10 minutes and off for 20 minutes to improve indoor air quality If the display shows FAN On Prog to indicate the program period has the fan programmed to run FAN Prog will override th...

Страница 10: ...th the times and temperatures you want Keep the following guidelines in mind when planning your program In Heating lower temperatures will save energy In Cooling higher temperatures will save energy I...

Страница 11: ...or is fixed In normal operation of the thermostat the current tempera ture displayed will be the weighted average of the local sensor and the remote sensor using the formula local sensor weight x loca...

Страница 12: ...at to COOL and lower the setpoint below the room temperature There may be up to a five minute delay before the thermostat clicks in Cooling Heat Cool or Fan Runs Constantly 1 Possible short in wiring...

Отзывы: