THERMOSTAT QUICK REFERENCE 

Home Screen Description

Figure 2 – Home Screen Display

1

  Displays   and "

Keypad Lockout" when in keypad 

lockout mode . 
Displays   and "

Temperature Limit" and "Keypad 

" when limited range is activated and locked . 
Displays only "

Temperature Limit" when limited range 

is activated .

2

  Indicates period of day being programmed .

3

  RUN SCHEDULE (run program) button .

4

  SET TIME button or HOLD temperature button .

5

  Displays "

Change Filter" when the system has run  

for the programmed filter time period as a reminder  
to change or clean your filter . 

6

  COPY button or INSTALLER CONFIG button .

7

  CLEAN DISPLAY button allows 30 seconds to wipe off 

the display or ADVANCE DAY button for programming .

8

  Used in programming to set time and in configuration 

menu to change selections .

9

  "

Hold Until" indicates the time when a temporary hold 

period will end .

10

  "

Hours" and "Days" displays during steps in installer 

configuration .

11

  The words "

Hold At" are displayed when the thermo- 

stat is in the 

HOLD mode . "Temporary Hold At" is 

displayed when the thermostat is in a temporary 

HOLD 

mode .

12

  "

Call For Service" indicates a fault in the heating/ 

cooling system . It does not indicate a fault in the 
thermostat .

Programming and Configuration Items

Figure 3 – Programming & Configuration Items

13

  "

System On" indicates when heating or cooling stage  

is energized . "

+2" also indicates when a second stage  

is energized . Flashing 

"+2" indicates when third stage is 

energized .

15

  A steady "

Cool Savings" display indicates the feature 

is enabled in the installer menu . A flashing "

Cool 

Savings" display indicates the feature is active .

16

  "

Remote" indicates that the indoor remote temperature 

sensor, is being accessed . "

Outdoor Remote" indicates 

the outdoor remote temperature sensor is being ac-
cessed .

Time of Day

Day of Week

Room

Temperature

System

Switch

Fan

Switch

Indicates when

thermostat is calling

for Heat or Cool

Battery Level Indicator

Indicating the current power level

of the 2 “AA” batteries.

         Full power remaining.

         Half power remaining.

Change

          The batteries should be replaced at this time.

Menu 

key for entering

different modes such as

Cleaning, Configuration, Set

Time and Set Schedule

Enters comfort

temperature settings

into the schedule

Temperature

UP/Down used for

modifying set point

as well as to

navigating the menus

Set Temperature

16

15

14 13

12

11

10

9

8

7

6

5

4

3

2

1

Содержание TP32W03

Страница 1: ...at contains mercury Mercury and products containing mercury must not be discarded in household trash Do not touch any spilled mercury Wearing non absorbent gloves clean up any spilled mercury and plac...

Страница 2: ...thermostat one at a time Do not let wires fall back into the wall Installing New Thermostat 1 Pull the thermostat body off the thermostat base Forcing or prying on the thermostat will cause damage to...

Страница 3: ...C W E Jumper G C W2 Jumper No Output 1st Stage Heat Cool Com pressor Blower Circula tor Fan Energiz ed on call for Heat or Cool 24 VAC Hot Cool DC supply voltage to re mote Temp erature Sensor Remote...

Страница 4: ...e 12 Call For Service indicates a fault in the heating cooling system It does not indicate a fault in the thermostat Programming and Configuration Items Figure 3 Programming Configuration Items 13 Sys...

Страница 5: ...I Selects Backlight Intensity 13 13 11 0 4 LO to 4 HI Selects Adjustable Ambient Temperature Display range 4 LO to 4 HI 14 14 12 F C Selects F C Display temperature units in Fahrenheit or Celsius 15 1...

Страница 6: ...and 98 F by pressing the or key The temperature limit icon will be displayed to the left of your setpoint temperature when using this feature The temperature limit icon will flash if an attempt is mad...

Страница 7: ...IGURATION MENU 2 C or more above the actual temperature using the second stage will energize immediately With FA OFF second stage will not energize until the setpoint tempera ture is 1 F or more above...

Страница 8: ...ure setting for a default four hour over ride period The override period can be shortened by pressing or lengthened by pressing Program Override period can range from 15 minutes to 7 days Example If y...

Страница 9: ...n the fan on for 10 minutes and off for 20 minutes to improve indoor air quality If the display shows FAN On Prog to indicate the program period has the fan programmed to run FAN Prog will override th...

Страница 10: ...th the times and temperatures you want Keep the following guidelines in mind when planning your program In Heating lower temperatures will save energy In Cooling higher temperatures will save energy I...

Страница 11: ...or is fixed In normal operation of the thermostat the current tempera ture displayed will be the weighted average of the local sensor and the remote sensor using the formula local sensor weight x loca...

Страница 12: ...at to COOL and lower the setpoint below the room temperature There may be up to a five minute delay before the thermostat clicks in Cooling Heat Cool or Fan Runs Constantly 1 Possible short in wiring...

Отзывы: