29
TROUBLESHOOTING PROCEDURES 2
Problem
Cause
Solution
6. Valve stalled in regeneration
a. Motor not operating
a. Replace motor
b. No power at outlet
b. Repair outlet or use working
outlet
c. Defective transformer
c. Replace transformer
d. Defective PC board
d. Replace PC board
e. Broken drive gear or drive cap
assy
e. Replace gear or drive cap assy
f.
Broken piston retainer
f.
Replace drive cap assembly
g. Broken main or regenerant
piston
g. Replace main or regenerant
piston
7. Valve does not regenerate
automatically when REGEN button
is pressed
a. Transformer unplugged
a. Connect transformer and PC
board power
b. No power at outlet
b. Restore power
c. Broken drive gear of drive cap
assembly
c. Replace gear or drive cap
assembly
d. Defective PC board
d. Replace board
8. Valve does not regenerate
automatically but does when
REGEN button is pressed
a. Bypass valve not in Normal
Operating Mode
a. See bypass diagrams
b. Meter disconnected
b. Reconnect to PC board
c. Obstructed meter turbine
c. Clear obstruction
d. Defective meter
d. Replace meter
e. Programming error
e. Review programming
f.
Defective PC board
f. Replace board
9. Time of day flashes on and off
a. Power has been out more than
two hours. Transformer was
unplugged form either wall outlet
or from PC board. NEXT and
REGEN were pressed to reset
the valve
a. Reset time of day
Содержание Deluxe Series
Страница 3: ...2 CONTROL VALVE SPECIFICATIONS...
Страница 23: ...22 REPLACEMENT PARTS...
Страница 24: ...23 REPLACEMENT PARTS...
Страница 25: ...24 REPLACEMENT PARTS...
Страница 26: ...25 REPLACEMENT PARTS...
Страница 27: ...26 INSTALLATION FITTING ASSEMBLIES...
Страница 28: ...27 WS1 IDENTIFICATION FIGURE WS1 WITH 1 050 DISTRIBUTOR TUBE OPENING IDENTIFICATION...
Страница 31: ...431 HURONIA RD UNIT 8 BARRIE ONTARIO L4N 9B3 www waterdepotinc com...