INSTALLER SETTINGS

 

STEP 1I

 - Press NEXT and 

 simultaneously for 3 seconds.  

 
 
 
 
 
 
 

STEP  2I

 

–  Hardness:  Set  the  amount  of  hardness  in  grains  of  hardness  as 

calcium  carbonate  per  gallon  using  the 

▲  or  ▼

  buttons.  The  default  is  20  with 

value ranges from 1 to 150 in 1 grain increments. Note: The grains per gallon can 
be increased if soluble iron needs to be reduced. This display  will show “–nA–” 
the  system  is  set  up  for  a  filter  or  if  „AUTO‟  is  not  selected  in  Step  7S.  Press 
NEXT to go to step 3I. Press REGEN to exit Installer Display Settings.  
 
 
 
 

 
 
 
STEP 3I

 

– Day Override: When gallon capacity is set to off, sets the number of 

days  between  regenerations.  When  gallon  capacity  is  set  to  AUTO  or  to  a 
number, sets the maximum number of days  between regenerations.  If value set 
to “oFF” regeneration initiation is based solely on gallons used. If value is set as 
a number (allowable range from 1 to 28) a regeneration initiation will be called for 
on  that  day  even  if  sufficient  number  of  gallons  were  not  used  to  call  for  a 
regeneration. Set Day Override using 

▲ or ▼

 buttons:  

•  number of days between regeneration (1 to 28); or 
•  “oFF”.  

See Setting Options Table for more detail on system setup. Press NEXT to go to 
step 4I. Press REGEN to return to previous step.  
 

STEP 4I

 

– Next Regeneration Time (hour): Set the hour of day for regeneration 

using 

▲ or ▼ 

buttons. AM/PM toggles after 12. The default time is 2:00 a.m. This 

display  will  show  “REGEN  on  0  GAL”  if  “on  0”  is  selected  in  Step  8S.  Press 
NEXT to go to step 5I. Press REGEN to return to previous step.  

 
 
 
 
 
 
 
 
 

STEP  5I

 

–  Next  Regeneration  Time  (minutes):  Set  the  minutes  of  day  for 

regeneration  using 

▲  or  ▼

 

buttons.  This  display  will  not  be  shown  if  “on  0”  is 

selected in Step 8S. Press NEXT to exit Installer Display Settings. Press REGEN 
to return to previous step.  
 
To  initiate  a  manual  regeneration  immediately,  press  and  hold  the  “REGEN” 
button  for  three  seconds.  The  system  will  begin  to regenerate  immediately.  The 
control  valve  may  be  stepped  through  the  various  regeneration  cycles  by 
pressing the “REGEN” button.  

 

Содержание Deluxe Series

Страница 1: ...PURPOSES AND TECHNICAL GUIDANCE IT IS STRONGLY RECOMMENDED THAT QUALIFIED DEALER SERVICE PERSONNEL BE CONTACTED IN THE EVENT OF AN UNKNOWN INTERRUPTION OF SERVICE OR APPARENT PRODUCT MALFUNCTION AN A...

Страница 2: ...LATION INSTRUCTIONS This unit has a control valve which enables the setting of not only the length of each regeneration cycle but also the order in which cycles steps of regeneration occur The followi...

Страница 3: ...2 CONTROL VALVE SPECIFICATIONS...

Страница 4: ...service the valve include one small blade screw driver one large blade screw driver pliers and a pair of hands A plastic wrench is available which eliminates the need for screwdrivers and pliers Disa...

Страница 5: ...nse cycle or have the regenerant prefill before regeneration If the OEM chooses to have the regenerant prefill before regeneration the prefill starts four hours before the regeneration time set During...

Страница 6: ...5 Table 4 Down Flow Softener Program Codes Table 5 Up Flow Softener Program Codes Table 6 Regenerating Filter Program Codes Table 7 Non Regenerating Filter Program Codes...

Страница 7: ...on time The user can cancel the request by pressing and releasing the REGEN button This method of manually initiating regeneration is not allowed when the system is set to on 0 i e immediately regener...

Страница 8: ...as time of day gallons remaining or days remaining before regeneration current ow rate or total gallons used are shown When stepping through a procedure if no buttons are pressed within ve minutes th...

Страница 9: ...d on the printed circuit board Following is an explanation of the options Off Feature not used dPon0 If the dP switch is closed for an accumulative time of 2 minutes a regeneration will occur immediat...

Страница 10: ...t Gallons Capacity using or buttons AUTO reserve capacity automatically estimated and gallons capacity automatically calculated from grains capacity and water hardness oFF regeneration based on day ov...

Страница 11: ...lons using the or buttons The choices are Relay Actuation Time After the start of a regeneration the amount of time that should pass prior to activating the relay The start of regeneration is de ned a...

Страница 12: ...11 SETTING OPTIONS TABLE STEP 1I STEP 2I STEP 3I STEP 4I 4 Reserve capacity estimate is based on history of water usage...

Страница 13: ...on water to the unit while also providing untreated water to the distribution system See Figure 1 2 Bypass Position The inlet and outlet handles point to the center of the bypass The system is isolate...

Страница 14: ...cord is furnished The tanks should be on a firm level surface The plug in transformer is for dry locations only Electrical Use a 115 120V 60Hz uninterrupted outlet Batteries are not used 1 The distan...

Страница 15: ...th the drain connection on the control valve This will provide an adequate anti siphon trap Where the drain empties into an overhead sewer line a sink type trap must be used Run drain tube to its disc...

Страница 16: ...ll be called for on that day even if sufficient number of gallons were not used to call for a regeneration Set Day Override using or buttons number of days between regeneration 1 to 28 or oFF See Sett...

Страница 17: ...lay shows the current treated water ow rate through the system The fourth display shows the total amount of treated water from 1x1000 to 9999x1000 gallons This is resettable by simultaneously pressing...

Страница 18: ...t the system will regenerate at the preset delayed regeneration time If you pressed the REGEN button in error pressing the button again will cancel the request Note If the regeneration time option is...

Страница 19: ...f an extended power outage occurs the time of day will ash on and off which indicates the time of day should be reset The system will remember the rest ERROR MESSAGE If the word ERROR and a number are...

Страница 20: ...ily to the drain without the presence of air restore power and momentarily press the REGEN button to advance the control to the BRINE position 5 Fully open the inlet bypass valve handle bypass is now...

Страница 21: ...2 sets of dry contacts for user applications The wiring of these contacts is application speci c Relay Speci cations To insure proper t and correct operation the following relay and relay socket manu...

Страница 22: ...ck Assembly 1 2 V3004 Drive Cap ASY 1 3 V3372 WS1MR Drive Back Plate 1 4a V3011 WS1 Piston Down ow ASY 1 4b V3011 01 WS1 Piston Up ow ASY 5 V3174 WS1 Regenerant Piston 1 6 V3135 O ring 228 1 7 V3180 O...

Страница 23: ...22 REPLACEMENT PARTS...

Страница 24: ...23 REPLACEMENT PARTS...

Страница 25: ...24 REPLACEMENT PARTS...

Страница 26: ...25 REPLACEMENT PARTS...

Страница 27: ...26 INSTALLATION FITTING ASSEMBLIES...

Страница 28: ...27 WS1 IDENTIFICATION FIGURE WS1 WITH 1 050 DISTRIBUTOR TUBE OPENING IDENTIFICATION...

Страница 29: ...et time of regeneration d Control set at on 0 d Check with regen time option in programming e Control set at NORMAL on 0 e Check with regen time option in programming 5 ERROR followed by a code number...

Страница 30: ...gged a Connect transformer and PC board power b No power at outlet b Restore power c Broken drive gear of drive cap assembly c Replace gear or drive cap assembly d Defective PC board d Replace board 8...

Страница 31: ...431 HURONIA RD UNIT 8 BARRIE ONTARIO L4N 9B3 www waterdepotinc com...

Отзывы: