Setting current time of day 

User programming   

User Programming Mode Steps (Refer to chart above for user mode indications) 

 

1. Press the Up and Down buttons simultaneously for five seconds while valve is in service. 

Display will enter programming mode. (Note: Timer will discard any changes and exit pro-

gramming mode if any button is not pressed for sixty seconds.) 

2. 

Set Day Override: 

This setting specifies the maximum number of days between regenera-

tion cycles. System will regenerate regardless of usage if the days since last regeneration  

cycle equals the day override setting. This ensures regular regeneration periods. In areas 

where nitrates range between 0-50 PPM, this setting should not exceed 6 days. If nitrate lev-

els exceed 50 PPM, please contact Water Control for a setpoint recommendation. 

 

Setting Current Time / Day  

 

1.  Press either the Up or Down button to adjust current time of day by one digit. Press and 

hold either the up or down button to adjust current time of day display by several digits.  

Ensure the AM/PM setting matches the current time of day.   

Start-Up Procedure 

Abbreviation 

Parameter 

Description 

DO 

Day Override 

The timer’s day override setting 

RT 

Regeneration Time 

The time of day that the system will 

regenerate 

Feed Water Hardness 

The hardness of the inlet water— 

used to calculate system capacity 

RC 

Reserve Capacity 

The fixed reserve capacity 

User Programming Mode Options 

6

 

Содержание Brassmaster Plus+ NitraMAX Series

Страница 1: ...e paid test bottles included To reorder visit watercontrolinc com nitramax nitrate removal or scan this QR code BrassMaster and BrassMaster Plus Technical Video Library https watercontrolinc com residential technical support residential technical videos BrassMaster technical videos demonstrate how to set up or remove the control module If replacing your control module please use the downloadable M...

Страница 2: ...etpoints are established based on water hardness levels unless combined ni trate nitrite levels exceed 50 PPM mg L If nitrate nitrite levels exceed 50 PPM please con tact Water Control Corporation for proper system setpoints Specifications NM 75 NM 125 Softening capacity grains 24 000 40 000 Cation softening media cu ft 0 75 1 25 Nitrate Nitrite Sulfate capacity raw water PPM or mg L 100 100 Anion...

Страница 3: ...ain line fitting and run to a nearby drain IMPORTANT It is highly recommended that a hose clamp be used to secure tubing to drain fitting to ensure tubing from being removed during elevated pressure situations Be sure not to submerse drain line end into drain as an 1 1 2 minimum air gap must be maintained to prevent potential backflow hazard Firmly secure at drain while maintaining a minimum 1 1 2...

Страница 4: ...and let go display will indicate BF Brine Fill cycle Allow timer to fill the brine tank for the entire time on the display The unit will advance to the service position when completed Push extra cycle button for 5 seconds this will start a manual regeneration from start to finish This will take approximately two hours Start up procedure is now complete The unit is now pressurized with water and re...

Страница 5: ...egeneration periods In areas where nitrates range between 0 50 PPM this setting should not exceed 6 days If nitrate lev els exceed 50 PPM please contact Water Control for a setpoint recommendation Setting Current Time Day 1 Press either the Up or Down button to adjust current time of day by one digit Press and hold either the up or down button to adjust current time of day display by several digit...

Страница 6: ...r Gal lon to this setting This will determine the amount of water usage allowed between regenera tion cycles NOTE If combined Nitrate Nitrite levels exceed 50 PPM contact Water Con trol for additional setpoint instructions 5 Set Fixed Reserve Capacity Press the Extra Cycle button to advance to next option Set the Fixed Reserve Capacity for the household This is the amount of water needed in reserv...

Страница 7: ...n from forming which will not allow the NitraMAX to regenerate properly The NitraMAX will regenerate but not recondition the media A salt bridge can be broken up using a broom handle or similar rod Carefully pound it into the salt and the pellets will collapse After loosening the salt pellets wait 2 hours and start a manual regeneration A second system regen eration may be needed to fully recondit...

Страница 8: ... FITNESS FOR A PARTICULAR PURPOSE WHAT IS NOT COVERED BY THESE WARRANTIES 1 Conditions damages and health effects resulting from any of the following Wear or malfunction caused by unfavorable water conditions Improper installation delivery or maintenance Any repair modification alteration or adjustment not authorized by the manufacturer or an authorized servicer Misuse abuse accidents or unreasona...

Отзывы: