Setting current time of day
User programming
User Programming Mode Steps (Refer to chart above for user mode indications)
1. Press the Up and Down buttons simultaneously for five seconds while valve is in service.
Display will enter programming mode. (Note: Timer will discard any changes and exit pro-
gramming mode if any button is not pressed for sixty seconds.)
2.
Set Day Override:
This setting specifies the maximum number of days between regenera-
tion cycles. System will regenerate regardless of usage if the days since last regeneration
cycle equals the day override setting. This ensures regular regeneration periods. In areas
where nitrates range between 0-50 PPM, this setting should not exceed 6 days. If nitrate lev-
els exceed 50 PPM, please contact Water Control for a setpoint recommendation.
Setting Current Time / Day
1. Press either the Up or Down button to adjust current time of day by one digit. Press and
hold either the up or down button to adjust current time of day display by several digits.
Ensure the AM/PM setting matches the current time of day.
Start-Up Procedure
Abbreviation
Parameter
Description
DO
Day Override
The timer’s day override setting
RT
Regeneration Time
The time of day that the system will
regenerate
H
Feed Water Hardness
The hardness of the inlet water—
used to calculate system capacity
RC
Reserve Capacity
The fixed reserve capacity
User Programming Mode Options