5
WA-253P7560
2. Replace all fill plugs.
3. Power on! Start the pump. If you don’t have water after 2
or 3 minutes, stop the pump and remove the fill plugs.
Refill the pump and piping. You may have to repeat this
several times in order to get all of the trapped air out of
the piping. A pump lifting water 25’ may take as long as
15 minutes to prime.
4. After the pump has built up pressure in the system and
shut off, check the pressure switch operation by opening a
faucet or two and running enough water out to bleed off
pressure until the pump starts. The pump should start
when the pressure drops to 30 PSI and stop when the
pressure reaches 50 PSI. Run the pump through one or two
complete cycles to verify correct operation. This will also
help clean the system of dirt and scale dislodged during
installation.
Congratulations on a successful installation.
If you were unsuccessful, please refer to the
Troubleshooting section (below) or call our
consumer hotline at 1-800-942-3343.
TROUBLESHOOTING
SYMPTOM
POSSIBLE CAUSE(S)
CORRECTIVE ACTION
Motor will not run
Fuse is blown or circuit breaker tripped
DISCONNECT POWER;Replace fuse or reset circuit breaker.
Motor runs hot and
Voltage is too low
Check voltage being supplied to the pump.
the overload kicks
off or the does not
run and only hums.
Motor runs but no
Pump during new installation did
In new installation:
water is delivered*
not pick up prime through:
1. Improper priming
1. Re-prime according to instructions.
2. Air leaks
2. Check all connections on suction line, with soapy water or
shaving cream.
3. Leaking foot valve
3. Replace foot valve.
4. Pipe size is too small
4. Re-pipe using size of suction and discharge ports on pump.
Pump has lost prime through:
In installation already in use:
1. Air leaks
1. Check all connections on suction line and shaft seal with soapy water.
2. Water level below suction pipe inlet
2. Lower suction line into water and re-prime. If receding water level
in well exceeds 25’ (7.6M), a deep well pump is needed.
Impeller is plugged
Clean impeller.
Foot valve is stuck shut
Replace the foot valve.
Pipes are frozen
Thaw pipes.
Foot valve and/or strainer are
Raise the foot valve and/or strainer above bottom of water source.
buried in sand or mud
Clean foot valve and strainer.
*Pump does not
Water being pumped is lower than
A deep well jet will may needed if the water being pumped is more than
deliver water to full
estimated
25’ (7.6M) depth to water.
capacity
Steel piping (if used) is corroded or
Replace with plastic pipe where possible, otherwise with new steel pipe.
limed, causing excess friction
Piping is too small in size
Re-pipe using size of suction and discharge ports on pump.
Pump not being supplied with
Add additional well points.
enough water
* (Note: Stop pump;
then check prime
before looking for
other causes. Unscrew
priming plug and see
if water is in priming
hole).