8. Go to the Sensor Pup Current Data tab to verify the expected
data parameters are coming in from each pup. If a sensor is not
connected, a dash will be displayed in the Data Value column.
For Station Pups, the
current condition can
only be seen in the
Pups tab.
The Retriever can now be disconnected from computer.
Configuration via USB Flash Drive
The Retriever configuration can be stored to a flash drive and
transferred to a Retriever in the field. The configuration process is
similar to the one for the direct PC connection except the
Retriever and Pup information must be entered manually.
1. Insert the flash drive into the PC and
bring up the RPLU software. Open the
“File” menu (fig. 4).
2. If a configuration for the desired
Retriever is already stored on the flash
drive, click the “Open Configuration”
option to modify that configuration.
Skip to step 5.
3. For new setups, click the “New
Configuration” option to configure a new
Retriever. This will bring up the “Start a
New Configuration” screen. Enter the
serial number for the Retriever and click
“OK”.
4. In the Retriever Settings screen,
click the “Manually Add New Pup”
Button. This will bring up the “Add a
Pup to Retriever Configuration”
screen. Enter the serial number for
the Pup and click “Add”. Repeat this
process for all Pups.
Figure 4. RPLU File
menu