User’s Manual AM-215A Series RS-485
6/8
Comparator data response
C
O
M CR LF
3
C
O
M
T
H
.
G
.
L CR LF
10
Note: The reading of the main unit changes to COM the moment it receives a COM command.
(Response with the status of the conparative output type function being set to
HI-GO-LO.)
C
O
M
T
H
H
.
H
.
G CR LF
11
(Response with the status of the conparative output type function being set to
HH-HI-GO.)
C
O
M
T
G
.
L
.
L
L CR LF
11
(Response with the status of the conparative output type function being set to
GO-LO-LL.)
N CR LF
1
S
-
H
I
1
0
0
0 CR LF
10
(Response with the HI-side judgment value.)
S
-
H
H
1
0
0
0 CR LF
10
(Response with the HH-side judgment value.)
S
-
L
O
5
0
0 CR LF
10
(Response with the LO-side judgment value.)
N CR LF
1
S
-
L
O
5
0
0 CR LF
10
(Response with the LO-side judgment value.)
S
-
H
I
5
0
0 CR LF
10
(Response with the HI-side judgment value.)
S
-
L
L
5
0
0 CR LF
10
(Response with the LL-side judgment value.)
N CR LF
1
H
-
H
I
0 CR LF
10
(Response with the HI-side hysteresis.)
H
-
H
H
0 CR LF
10
(Response with the HH-side hysteresis.)
H
-
L
O
0 CR LF
10
(Response with the LO-side hysteresis.)
N CR LF
1
H
-
L
O
0 CR LF
10
(Response with the LO-side hysteresis.)
H
-
H
I
0 CR LF
10
(Response with the HI-side hysteresis.)
H
-
L
L
0 CR LF
10
(Response with the LL-side hysteresis.)
N CR LF
1
L
-
H
I
N
.
O CR LF
8
(Response with the status of the HI-side logic function being set to N.O.)
L
-
H
I
N
.
C CR LF
8
(Response with the status of the HI-side logic function being set to N.C.)
L
-
H
H
N
.
O CR LF
8
(Response with the status of the HH-side logic function being set to N.O.)
L
-
H
H
N
.
C CR LF
8
(Response with the status of the HH-side logic function being set to N.C.)
L
-
G
O
N
.
O CR LF
8
(Response with the status of the GO logic function being set to N.O.)
L
-
G
O
N
.
C CR LF
8
(Response with the status of the GO logic function being set to N.C.)
N CR LF
1
L
-
G
O
N
.
O CR LF
8
(Response with the status of the GO logic function being set to N.O.)
L
-
G
O
N
.
C CR LF
8
(Response with the status of the GO logic function being set to N.C.)
L
-
H
I
N
.
O CR LF
8
(Response with the status of the HI-side logic function being set to N.O.)
L
-
H
I
N
.
C CR LF
8
(Response with the status of the HI-side logic function being set to N.C.)
L
-
L
O
N
.
O CR LF
8
(Response with the status of the LO-side logic function being set to N.O.)
L
-
L
O
N
.
C CR LF
8
(Response with the status of the LO-side logic function being set to N.C.)
N CR LF
1
L
-
L
O
N
.
O CR LF
8
(Response with the status of the LO-side logic function being set to N.O.)
L
-
L
O
N
.
C CR LF
8
(Response with the status of the LO-side logic function being set to N.C.)
L
-
G
O
N
.
O CR LF
8
(Response with the status of the GO logic function being set to N.O.)
L
-
G
O
N
.
C CR LF
8
(Response with the status of the GO logic function being set to N.C.)
L
-
L
L
N
.
O CR LF
8
(Response with the status of the LL-side logic function being set to N.O.)
L
-
L
L
N
.
C CR LF
8
(Response with the status of the LL-side logic function being set to N.C.)
N CR LF
1
A
L
1
H
H CR LF
7
(Response with the HH-side, lighting up condition of AL1.)
A
L
1
H
I
CR LF
7
(Response with the HI-side, lighting up condition of AL1.)
A
L
1
G
O CR LF
7
(Response with the GO-side, lighting up condition of AL1.)
A
L
1
L
O CR LF
7
(Response with the LO-side, lighting up condition of AL1.)
A
L
1
L
L CR LF
7
(Response with the LL-side, lighting up condition of AL1.)
N CR LF
1
A
L
2
H
H CR LF
7
(Response with the HH-side, lighting up condition of AL2.)
A
L
2
H
I
CR LF
7
(Response with the HI-side, lighting up condition of AL2.)
A
L
2
G
O CR LF
7
(Response with the GO-side, lighting up condition of AL2.)
A
L
2
L
O CR LF
7
(Response with the LO-side, lighting up condition of AL2.)
A
L
2
L
L CR LF
7
(Response with the LL-side, lighting up condition of AL2.)
R CR LF
1
Y
E
S
CR LF
5
Note: The main unit returns to measurement operation upon an R command
(or returns to the comparison output if an N command is sent.)
Comparator data setting
C
O
M CR LF
3
C
O
M
T
H
.
G
.
L CR LF
10
Note: This example shows a case
Note: The reading of the main unit changes to COM the moment it receives a COM command.
(Response with the status of the conparative output type function being set to
where COMT is HH-HI-GO and S-HH is
HI-GO-LO.)
set to 8000 and S-HI to 4000.
H
H
.
H
.
G CR LF
6
C
O
M
T
H
H
.
H
.
G CR LF
11
(Sets the comt to HH-HI-GO..)
N CR LF
1
S
-
H
H
1
0
0
0 CR LF
10
8
0
0
0 CR LF
4
S
-
H
I
8
0
0
0 CR LF
10
(Sets the HH-side judgment value to 8000.)
N CR LF
1
S
-
L
O
5
0
0 CR LF
10
4
0
0
0 CR LF
4
S
-
L
O
4
0
0
0 CR LF
10
(Sets the HI-side judgment value to 4000.)
N CR LF
1
H
-
H
H
0 CR LF
10
N CR LF
1
H
-
H
I
0 CR LF
10
N CR LF
1
L
-
H
H
N
.
O CR LF
8
N
.
C CR LF
3
L
-
H
H
N
.
C CR LF
8
R CR LF
1
Y
E
S
CR LF
5
E
r
r
o
r
CR LF
6
(Response when a value that does not meet the setting conditions is input.)
Note: If an R command is sent after setting required data, the main unit saves data provided
up to that moment and then returns to measurement operation.