User’s Manual AM-215A Series RS-485

                                                                       7/8 

Scaling data response

M

E

T CR LF

3

F

S

C

9

9

9

9 CR LF

10

Note: The reading of the main unit changes to MET the moment it receives an MET command.

(Response with a full-scale reading.)

N CR LF

1

F

I

N

9

9

9

9 CR LF

10

(Response with a full-scale input value.)

N CR LF

1

O

F

S

0 CR LF

10

(Response with an offset reading.)

N CR LF

1

O

I

N

0 CR LF

10

(Response with an offset input value.)

N CR LF

1

D

L

H

I

9

9

9

9 CR LF

10

(Response with the HI value of the digital limiter.)

N CR LF

1

D

L

L

O

-

9

9

9

9 CR LF

10

(Response with the LO value of the digital limiter.)

N CR LF

1

D

E

P

4 CR LF

6

(Response with the position of the decimal point.)

R CR LF

1

Y

E

S

CR LF

5

Scaling data setting

M

E

T CR LF

3

F

S

C

9

9

9

9 CR LF

10

Note: This example shows a case

Note: The reading of the main unit changes to MET the moment it receives an MET command.

where FSC is set to 8000 and OFS

8

0

0

0 CR LF

4

F

S

C

8

0

0

0 CR LF

10

to 20.

(Sets the full-scale reading to 8000.)

N CR LF

1

F

I

N

9

9

9

9 CR LF

10

N CR LF

1

O

F

S

0 CR LF

10

2

0 CR LF

2

O

F

S

2

0 CR LF

10

(Sets the offset reading to 20.)

R CR LF

1

Y

E

S

CR LF

5

E

r

r

o

r

CR LF

6

(Response when a value outside the setpoint range is input.)

Linearization function status

L

I

N CR LF

3

L

I

N

O

F

F CR LF

7

response

(Response with the status of the linearization function being set to OFF.)

L

I

N

O

N CR LF

6

(Response with the status of the linearization function being set to ON.)

L

I

N

C

L

R CR LF

7

(Response with the status of the linearization function being cleared.)

Linearization function status setting

L

I

N

O

F

F CR LF

7

Y

E

S

CR LF

5

(Sets the linearization function to an OFF status.)

L

I

N

O

N CR LF

6

Y

E

S

CR LF

5

(Sets the linearization function to an ON status.)

L

I

N

C

L

R CR LF

7

Y

E

S

CR LF

5

(Sets the linearization function to a cleared status.)

N

O

?

CR LF

5

(Response with the status of the linearization function being cleared.)
Note: Since the linearization data are all cleared when the linearization function
is cleared, the main unit does not accept either a LIN ON or LIN OFF command.
(Set the linearization function status after setting the linearization data again.)

Response for number of linearization

L

N

O CR LF

3

L

N

O

0

0 CR LF

6

correction data items

(Response with the status of the linearization function being cleared.)

L

N

O

0

2 CR LF

6

(Response with the status of the number of linearization correction data items
being 02.)

L

N

O

1

6 CR LF

6

(Response with the status of the number of linearization correction data items
being 16.)

Setting for number of linearization

L

N

O

0

2 CR LF

6

Y

E

S

CR LF

5

correction data items

(Sets the number of linearization correction data items to 02.)

L

N

O

1

6 CR LF

6

Y

E

S

CR LF

5

(Sets the number of linearization correction data items to 16.)

E

r

r

o

r

CR LF

6

(Response when linearization data is not correctly set.)
Note: Set the number of linearization correction data items after setting
linearization data.)

Linearization data response

L

N

D

0

1 CR LF

6

L

N

D

0

1

I

=

0 CR LF

14

Note: A reading can be made from any of the data items 01 to 16.

(Response with the input value of linearization data N-01.)

Note: The reading of the main unit changes to LINE the moment it receives an LND XX
command.

N CR LF

1

L

N

D

0

1

O

=

0 CR LF

14

(Response with the output value of linearization data N-01.)

N CR LF

1

L

N

D

0

2

I

=

0 CR LF

14

(Response with the input value of linearization data N-02.)

N CR LF

1

L

N

D

0

2

O

=

0 CR LF

14

(Response with the output value of linearization data N-02.)

N CR LF

1

L

N

D

0

3

I

=

0 CR LF

14

N CR LF

1

L

N

D

1

6

I

=

0 CR LF

14

(Response with the input value of linearization data N-16.)

N CR LF

1

L

N

D

1

6

O

=

0 CR LF

14

(Response with the output value of linearization data N-16.)

R CR LF

1

Y

E

S

CR LF

Linearization data setting

L

N

D

0

1 CR LF

6

L

N

D

0

1

I

=

0 CR LF

14

Note: Setting can be made from any of the data items 01 to 16.
Note: The reading of the main unit changes to LINE the moment it receives an LND XX
command.

-

1

0

0

0 CR LF

5

L

N

D

0

1

I

=

-

1

0

0

0 CR LF

14

(Sets the input value of linearization data N-01 to -1000.)

N CR LF

1

L

N

D

0

1

O

=

0 CR LF

14

-

9

0

0 CR LF

4

L

N

D

0

1

O

=

-

9

0

0 CR LF

14

(Sets the output value of linearization data N-01 to -900.)

N CR LF

1

L

N

D

0

2

I

=

0 CR LF

14

-

5

0

0 CR LF

4

L

N

D

0

2

I

=

-

5

0

0 CR LF

14

(Sets the input value of linearization data N-02 to -500.)

N CR LF

1

L

N

D

0

2

O

=

0 CR LF

14

-

6

0

0 CR LF

4

L

N

D

0

2

O

=

-

6

0

0 CR LF

14

(Sets the output value of linearization data N-01 to -600.)



R CR LF

1

Y

E

S

CR LF

5

E

r

r

o

r

CR LF

6

(Response when a value outside the setpoint range is input.)

Note: If an R command is sent after setting required data, the main unit saves data provided
up to that moment and then returns to measurement operation.

Note: The main unit returns to measurement operation upon an R command (or returns to
the response with the full-scale reading if an N command is sent.)

Note: The main unit returns to measurement operation upon an R command (or returns to
the response with the input value of linearization data N-01 if an N command is sent.)

Note: If an R command is sent after setting required data, the main unit saves data provided
up to that point and then returns to measurement operation.

Содержание AM-215A

Страница 1: ...TOR ANALOG OUT or RS485 INPUT EXC POWER c e c e c e AL1 AL2 SET POINT COMPARATOR AM 215A INSTRUCTION MANUAL Caution 1 The equipment may be damaged if the input current or voltage exceeds the maximum...

Страница 2: ...y When using a 2 wire sensor terminals 2 11 should be externally connected 4 When no terminals are selected for outputting do not connect anything to vacant terminals AL1 AL2 Condition data A group of...

Страница 3: ...et The default value is 9999 The default value is 9999 A menu is displayed only the option output form 4 The default value is 0 A displayed value to obtain an output from the full scale side of the an...

Страница 4: ...g temperature and humidity ranges 0 to 50 C 35 to 85 RH no condensation Storage temperature and humidity ranges 20 to 70 C 60 or lower RH no condensation Supply voltage DC 24 V 20 Consumed power Appro...

Страница 5: ...inearity compensation of the rectifying point 2 is inputted The input value display value before linearity compensation of the rectifying point 16 is inputted The output value display value before lin...

Страница 6: ...ransmission control procedure Signal name used Number of units that can be connected Transmission line length Delimiter Parity bit Start stop Two wire half duplex polling selecting 2400 4800 9600 1920...

Страница 7: ...to ON AL1 AL2 AL1 AL2 AL1 AL2 AL1 AL2 Function 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 Char Length 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 Char Length Establishment of...

Страница 8: ...0 H I CR LF 10 reading w o decimal point 5 0 0 0 H I CR LF 11 reading w decimal point 9 8 0 0 H I CR LF 10 overrange reading w o decimal point 9 8 0 0 H I CR LF 11 overrange reading w decimal point M...

Страница 9: ...3 Response with the status of the hold function being remote controlled D Z R CR LF 3 Response with the status of the digital zero function being remote controlled R L Y CR LF 3 Response with the sta...

Страница 10: ...T 1 W 1 CR LF 14 Response with the status of the tracking zero time being 1 and tracking zero width being 1 T R K O N T 9 9 W 9 9 CR LF 16 Response with the status of the tracking zero time being 99 a...

Страница 11: ...O side logic function being set to N C N CR LF 1 L L O N O CR LF 8 Response with the status of the LO side logic function being set to N O L L O N C CR LF 8 Response with the status of the LO side log...

Страница 12: ...on correction data items being 16 Setting for number of linearization L N O 0 2 CR LF 6 Y E S CR LF 5 correction data items Sets the number of linearization correction data items to 02 L N O 1 6 CR LF...

Страница 13: ...unication parameter failure Note Under normal conditions this response is made only once Note ERROR B to ERROR F are available as the response commands for acknowledgment Note If a response to the ERR...

Отзывы: