background image

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

1. 

Before using the product

 

Thank you for purchasing the AM-215A Series. Keep this operating manual handy 

so that you can refer to it in the future. Check the contents of your package 

and contact your dealer or Watanabe if you notice any problems (e.g., equipment 

damage). 

1.1.Equipment numbers 

The equipment numbers used with the AM-215A Series follow the chart shown 

below. Make sure the product you selected when you placed your order has the 

same model number and specifications as the product you received.

 

 
 
 
 
 
 
 
 
 
 

1.2.  Standard accessories check

 

The AM-215A package includes an operating manual (this document) and one unit 

seal. 

2. 

 Panel cutting dimensions

 

2.1.  Panel cutting dimensions 

Follow the dimensions shown in the diagram below in cutting the panel in order 

to install the AM-215A Series.

 

 

 

 

 

 

 

 
 

2.2.   External dimensions 

 

 

 

 

 

 

 

 

 

 

2.3.   Panel attachment procedure 

After removing the attachment bands from the main unit, insert the unit 

through the front of the panel, and fasten it from the rear side of the panel 

using the attachment bands. 

 

 

 

 

 

 

 

 
 
 
 

3. 

 Description of terminals and connection 

procedure

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

①②:Input signals

 

• 

Make the input signal lines as short as possible. Keep them away from other 

signal lines. 

• 

If there is a lot of external noise, use a two-wire shielded cable and form 

a single connection between the outer sheath and the LO side at the signal 

source. 

 

Instruction Manual for MODEL    AM-215A UL                                                                   1/4 

UX-34107k 

2016.01 

AL1 AL2

48.0

2

4.

0

3

4

.

2

84.3

3.5

2

2

.

0

+24V

10

0V

11

12

13

14

15

16

17

18

1

2

3

4

5

6

7

8

9

COM

a

c

a

c

a

c

OUT3

OUT2

OUT1

+V

0V

POWER

HI

LO

+

-

DZ

TERMINA

TOR

ANALOG

OUT

or

RS485

INPUT

EXC

POWER

!

(c)

(e)

(c)

(e)

(c)

(e)

AL1 AL2

SET POINT COMPARATOR

AM-215A INSTRUCTION MANUAL

   Caution

!

(1)

The equipment may be damaged if the input current or voltage exceeds 
the maximum allowed value.

(2)

Only use a supply voltage which is in the usable voltage range. Using a 
voltage outside this range may result in fire, electric shock, or damage to 
the equipment. 

(3)

Please note that the contents of this manual may be changed without 
notice due to product modifications. 
In preparing this manual, we made every effort to provide the best manual 
possible.  Please contact your dealer or Watanabe if you notice any 
deficiencies, errors, omissions, etc.

 

(4)

After you finish reading the manual, keep it handy for future access. 

(5)

A M - 2 1 5

- X X - X X

Comparator output

1:Relay contact output
2:Photocoupler output

Option output

1:None
4:RS-485 interface
6:Analog output(4-20mA)
7:Analog output(0-10V)

Input range

11:1-99.99mV)
12:1-999.9mV)
13:1-9.999V)
1V:1VRange(1-5V)
2A:2ARange(4-20mA)

Basic model

Series name

A

+0.5

-0

45.0

2

2

.2

+

0

.3

-0

MIN 

57

M

IN

 5

0

* Recommended panel 

thickness: 1-8 mm

WATANABE ELECTRIC INDUSTRY CO., LTD.

 

 

Caution

Make sure the installation location is strong enough to support the unit's weight. If it is 
not strong enough, or if the unit is not properly attached, the display may fall, possibly 
resulting in injury.

(1)

(2) When installing the unit in a system, be sure there is sufficient heat dissipation so that the 

temperature inside the system does not reach or exceed 50°C.

!

Thickness: AWG28-16

Wire exposed length: 
5-6 mm

Connection using wire

Connection using rod 
terminal

5

-6

m

m

5

-6

m

m

Dimensions of terminal 
block opening

2

.2

1.8

M2.5 Phillips screwdriver 

Recommended 
torque: 0.4 Nm

AM-215 terminal block side view

Содержание AM-215A

Страница 1: ...TOR ANALOG OUT or RS485 INPUT EXC POWER c e c e c e AL1 AL2 SET POINT COMPARATOR AM 215A INSTRUCTION MANUAL Caution 1 The equipment may be damaged if the input current or voltage exceeds the maximum...

Страница 2: ...y When using a 2 wire sensor terminals 2 11 should be externally connected 4 When no terminals are selected for outputting do not connect anything to vacant terminals AL1 AL2 Condition data A group of...

Страница 3: ...et The default value is 9999 The default value is 9999 A menu is displayed only the option output form 4 The default value is 0 A displayed value to obtain an output from the full scale side of the an...

Страница 4: ...g temperature and humidity ranges 0 to 50 C 35 to 85 RH no condensation Storage temperature and humidity ranges 20 to 70 C 60 or lower RH no condensation Supply voltage DC 24 V 20 Consumed power Appro...

Страница 5: ...inearity compensation of the rectifying point 2 is inputted The input value display value before linearity compensation of the rectifying point 16 is inputted The output value display value before lin...

Страница 6: ...ransmission control procedure Signal name used Number of units that can be connected Transmission line length Delimiter Parity bit Start stop Two wire half duplex polling selecting 2400 4800 9600 1920...

Страница 7: ...to ON AL1 AL2 AL1 AL2 AL1 AL2 AL1 AL2 Function 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 Char Length 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 Char Length Establishment of...

Страница 8: ...0 H I CR LF 10 reading w o decimal point 5 0 0 0 H I CR LF 11 reading w decimal point 9 8 0 0 H I CR LF 10 overrange reading w o decimal point 9 8 0 0 H I CR LF 11 overrange reading w decimal point M...

Страница 9: ...3 Response with the status of the hold function being remote controlled D Z R CR LF 3 Response with the status of the digital zero function being remote controlled R L Y CR LF 3 Response with the sta...

Страница 10: ...T 1 W 1 CR LF 14 Response with the status of the tracking zero time being 1 and tracking zero width being 1 T R K O N T 9 9 W 9 9 CR LF 16 Response with the status of the tracking zero time being 99 a...

Страница 11: ...O side logic function being set to N C N CR LF 1 L L O N O CR LF 8 Response with the status of the LO side logic function being set to N O L L O N C CR LF 8 Response with the status of the LO side log...

Страница 12: ...on correction data items being 16 Setting for number of linearization L N O 0 2 CR LF 6 Y E S CR LF 5 correction data items Sets the number of linearization correction data items to 02 L N O 1 6 CR LF...

Страница 13: ...unication parameter failure Note Under normal conditions this response is made only once Note ERROR B to ERROR F are available as the response commands for acknowledgment Note If a response to the ERR...

Отзывы: