background image

 5  Application

The 

Timobil

 is a stand-alone dust extractor with an integrated handpiece for use in the 

laboratory and in the field. It is especially useful for cutting and trimming dental appliances 

while sitting on a bench stool.

Only use the device for this type of application.

 6  Before Starting

 6.1 

Transport

Before transporting the unit, ensure that it has been unplugged from the power socket. 

Make sure that it is packed correctly in order to avoid accidental damage.

Be sure to check for any transport damage when unpacking the goods. Note down 

any damage if found.

 6.2 

Storage

The unit location is very important when it comes to workplace safety, even if it is only to 

be set up there for a short period. The room should be dry, well ventilated and vibration-

free. An even temperature and wooden supports also help. The unit should not be stored 

or set up outdoors. If the unit is to be stored for an extended period, protect it from 

moisture and dust.

7

Содержание 149996

Страница 1: ...Suction Unit Timobil Mobil Suction Table with Motor Handpiece USER MANUAL ...

Страница 2: ...dents as well as the precautions given in this user manual We are not liable for any damages which occur due to inappropriate usage or faulty operation of this device Make sure that anyone using this device has read and understood this user manual Keep this user manual in a safe place where it can be referred to as required at any time The unit complies with the relevant EU guidelines The unit is ...

Страница 3: ...on Start up 8 8 Operation 9 8 1 General Operating Instructions 9 9 Troubleshooting 9 10 Care and Maintenance 10 10 1 Repairs 10 10 2 Changing the Filter 10 10 3 Spare Parts 10 10 4 Service Hotline 0049 0 40 730 926 20 24 10 10 5 Cleaning 11 10 6 Cleaning and or Servicing the Chuck 11 10 7 Scope of Delivery Accessories 12 11 Technical Data 12 12 Disposing of the Unit 13 12 1 Information on Disposal...

Страница 4: ...and closes the chuck The unit has overload protection Works with the low pressure principle No heat eduction no cooling of hands high suction volume virtually noiseless operation runs quietly suitable for continuous operation With robust and ergonomic equipment engine Strong torque high rotation accuracy and brushless motor Suction unit can be started automatically by the motor handpiece High prot...

Страница 5: ... equipment requires precise knowledge and observance of the instructions in this user manual The equipment is designed only for its intended application WARNING Servicing and repairs should be carried out only by authorised specialists Disconnect the power plug before starting any maintenance work Make sure that the equipment is connected to the correct power source WARNING Risk of injury You shou...

Страница 6: ...tal Maschinen GmbH is not responsible for damage arising from the nonobservance of these instructions Warranty and responsibility provisions contained in the sales and supply conditions of Wassermann Dental Maschinen GmbH are not extended by these instructions 4 1 Warranty The warranty period for our equipment is 12 months If faults occur within the warranty period contact your dental depot or get...

Страница 7: ...rom the power socket Make sure that it is packed correctly in order to avoid accidental damage Be sure to check for any transport damage when unpacking the goods Note down any damage if found 6 2 Storage The unit location is very important when it comes to workplace safety even if it is only to be set up there for a short period The room should be dry well ventilated and vibration free An even tem...

Страница 8: ...ipation Do not install the unit outdoors or in places without proper ventilation Before start up be sure the device reaches room temperature 7 Installation Start up 1 Pull the cable out slowly it will stop at the desired length 2 Pull the cable out quickly it will roll back fully onto the drum 3 Finally insert the power plug into the socket making sure that the mains and the unit operate on the sa...

Страница 9: ...Solution Little or no extraction Filter bag full Change filter bag No power Microswitch wrongly adjusted Reset microswitch Contact our Service Department Motor switches off Overload protection Allow unit to cool Motor does not run Chuck mechanism open Close chuck mechanism Little or no extraction Filter bag full Change filter bag If the above recommendations do not solve the problem contact your d...

Страница 10: ... Filter The unit has a one way filter bag which is easy to change when it is full Undo the locks on the right and left and remove the cover You can now replace the full bag with a new one Change the filter regularly to guarantee trouble free dust extraction It is time to change the bag if the extraction power becomes noticeably weaker and or if dust collects in the extractor area 10 3 Spare Parts ...

Страница 11: ... 6 Cleaning and or Servicing the Chuck WARNING Risk of injury You should change the tool or the chuck only after the motorised handpiece has come to a complete stop Do not touch the rotating tool 1 Open the chuck 2 Unscrew the plastic tip by turning it manually to the left 3 Insert the chuck key fully into the chuck 4 Hold the shaft firmly with an adjustable wrench 5 Undo the chuck by turning the ...

Страница 12: ...filterbag for plaster class 1 class 2 1 set 4 pieces 611018 Storage tray 149010 11 Technical Data Timobil Artikel Nr 149999 Voltage 220 240 V 50 60 Hz Power consumption 1 5 A Plug socket power consumption max 8 A Output 350 W W x H x D 530 x 900 x 480 mm Weight 28 1 kg Suction capacity 500 m3 h free blowing Control unit output 160 W Handpiece motor output 95 W Handpiece motor speed 1000 40 000 min...

Страница 13: ...otect the environment prevent environmental pollution and improve the recycling of raw materials the European Commission adopted a directive that requires the manufacturer to accept the return of electrical and electronic units for proper disposal or recycling Within the European Union units with this symbol should not therefore be disposed of in unsorted domestic waste For more information regard...

Страница 14: ...mmung verändert wird This is to confirm that the above mentioned machine complies with the described EU guidelines This declaration becomes invalid if the machine is modified without our approval Cette machine est conforme aux normes en vigueur d Union européenne Cet avis est nul et non avenant si cette machine est modifiée sans notre accord Esta máquina anteriormente mencionada cumple con los lim...

Страница 15: ...Notes 15 ...