background image

 

 

- 13 -

 

10  EC conformity certificate 

 

in  accordance  with  73/23/EWG  (low-voltage  guidelines)  modified  by  93/68/EWG 
and  89/336/EWG  (EMV  guidelines)  and  89/392/EWG  (Machinery  guidelines),  with 
modifications 

 

Manufacturer: 

W A S S E R M A N N 
Dental-Maschinen GmbH 
Rudorffweg 15 - 17 
D-21031 Hamburg  

Product description:  

Laboratory 

rotary 

tool 

for 

dental 

applications 

 

Model: 

HSM-500 laboratory bench top rotary tool HSM-500   111994 

 

Applicable 
standards: 

EN 61010-1:1993 + A2:1995 
EN 60335/2/54   03.97 
EN 50081-1 + EN 50082-1 
 

 

Hiermit wird bestätigt, dass die oben bezeichnete Maschine den genannten EG-Richtlinien 
entspricht. Diese Erklärung wird ungültig, falls die Maschine ohne unsere Zustimmung 
verändert wird. 
 
This is to confirm that the above mentioned machine complies with the described EC rules. This 
declaration becomes invalid if the machine is modified without our approval. 
 
Cette machine est conforme aux normes en vigueur de la Communité Européene. Cet avis est 
nul et non avenant si cette machine est modifiée sans notre accord. 
 
Esta máquina, anteriormente mencionada, cumple con los limites requeridos por el reglamento 
EC. Ahora bien, esta declaración quedará invalidada en caso de realizar modificaciones al 
aparato sin nuestra aprobación. 
 
Hiermee wordt bevestigd dat bovengenoemde machine voldoet aan de voorgeschreven EU 
normen. Deze verklaring verliest geldigheid als er zonder onze uitdrukkelijke toestemming 
wijzigen aan de machine worden aangebracht. 
 
 
Place, date: Hamburg, 10 April 2003 
 
 
                       

Company stamp: 
 
 

Signed: ________________________ 
                            Wilfried Wassermann 
                               (Managing Director) 

 

 

 

Содержание HSM-500

Страница 1: ...WASSERMANN DENTAL MASCHINEN GMBH User manual HSM 500 bench top rotary tool...

Страница 2: ...ully before you start work and operate the unit according to the recommended guidelines Please ensure that all persons operating the equipment have read and understood this user manual Keep this user...

Страница 3: ...Use Application 7 4 Before you start 7 4 1 UNPACKING TRANSPORT 7 4 2 CONTENTS 8 5 Switch functions 8 5 1 POWER SWITCH 8 5 2 CONTROL ROCKER SWITCH 8 5 3 DIRECTION ROCKER SWITCH 8 5 4 SPEED CONTROL KNOB...

Страница 4: ...observe this warning could be life threatening These warnings must be observed Information This symbol draws your attention to specific features which must be observed 1 3 Safety guidelines Configurin...

Страница 5: ...peration and damage The responsibility for operating the unit lies exclusively with the owner or user if the said unit is incorrectly serviced maintained or altered by persons not employed by an accre...

Страница 6: ...al is accessible at all times and has been read and understood 2 Care and maintenance 2 1 Maintenance The equipment should be cleaned at regular intervals to ensure trouble free operation It requires...

Страница 7: ...to the left Use a brush to clean the shaft and then lubricate the chuck and the bore with two drops of oil each Insert the chuck by hand Make sure that the chuck mechanism is still open Insert the ch...

Страница 8: ...acking Transport Open the cartons remove the packing materials and carefully lift out the instrument and accessories Check that the accessories are correct When transporting the unit use appropriate p...

Страница 9: ...ains switch lights green 5 2 CONTROL rocker switch This switch enables you to control the tool by hand or knee 5 3 DIRECTION rocker switch The DIRECTION rocker switch controls the direction of rotatio...

Страница 10: ...to the left you will feel and hear it clicking into place Warning Always turn the handpiece casing up to the stop 6 Installation 6 1 Installing the motor mains and foot switch cables At the rear of t...

Страница 11: ...tion Tighten the motor cable swivel nut by turning it clockwise by hand Warning Do not use pliers 7 Start up Check that the rotating tool has been inserted up to the stop Set the CONTROL switch to foo...

Страница 12: ...ystem error Send unit in for service If the above recommendations do not solve the problem contact your dental depot or our Service department 8 2 Technical data Voltage switchable 220 240 V 50 60 Hz...

Страница 13: ...o be used Responsibility for the product is voided if altered by unauthorized persons or if inappropriate components are installed 9 Warranty The warranty period for our equipment is 12 months If faul...

Страница 14: ...ert wird This is to confirm that the above mentioned machine complies with the described EC rules This declaration becomes invalid if the machine is modified without our approval Cette machine est con...

Страница 15: ...14...

Страница 16: ...WASSERMANN Dental Maschinen GmbH Rudorffweg 15 17 D 21031 Hamburg Tel 49 0 40 730 926 0 Fax 49 0 40 730 37 24 e mail info wassermann dental com Internet http www wassermann dental com...

Отзывы: