6
Operation
Switch on the device; the toggle switch lights green.
To clean the pipes and dosage pump, perform the following upon
first start-up
as
well as when replacing the bottles: Position a container under the mixing head
without the mixing cannula, press the red button and hold it until both components
run evenly and without bubbles from the mixing cannula adaptors.
Mount the mixing cannula by turning it 90° on the mixing cannula adaptor (clean
the adaptor before if necessary). Place the bowl or the model to be used for
doubling the system under the mixing cannula. Press the red button: 1:1 mixed
silicone runs out of the mixing cannula.
We recommend collecting a small amount of the mixture initially output and just
letting the substance output subsequently run into the form. You can fill more forms
without changing the mixing cannula as long as the period between the single
dosage operations lies within the dripping time of the used silicone (about 4 min.).
The dosage machine 1:1 dispenses mixed silicone as long as you press the red
button.
After use, leave the mixing cannula attached to the device and allow the remaining
silicone to vulcanise. This closes the openings of both components sufficiently.
A new mixing cannula must to be fitted after hardening and before further usage.
WARNING: Never use with a hardened mixing cannula!
Very important:
Do not continue operation if one or both containers are empty; otherwise the
pipes will convey air (observe the minimum liquid level of the containers: ~ 2-3
cm!).