Enter/Exit Programming Mode
PDF417
186
WDI4600
PDF417
PDF417 Enable / Disable
Enables/disables the ability of the reader to decode PDF417 labels.
$CP4EN00(CR)
PDF417 = Disable
$CP4EN01(CR)
PDF417 = Enable
DEFAULT
PDF417 Length Control
This feature specifies either variable length decoding or fixed length decoding for this
symbology.
Variable Length:
For variable length decoding, a minimum and maximum length may be set.
Fixed Length:
For fixed length decoding, two different lengths may be set.
DEFAULT
$CP4LC00(CR)
PDF417 Length Control = Variable Length
$CP4LC01(CR)
PDF417 Length Control = Fixed Length