Enter/Exit Programming Mode
Code 93
160
WDI4600
Code 93 Set Length 1
Specifies one of the barcode lengths for
. Length 1 is the minimum
label length if in
Mode, or the first fixed length if in
Length includes the barcode’s data characters only. The length can be set from 01 to 50
characters.
provides some examples for setting Length 1. See
for detailed instructions on
setting this feature.
Table 19. Code 93 Length 1 Setting Examples
STEP
ACTION
EXAMPLES
1
Desired Setting
01 Characters
07 Characters
15 Characters
50 Characters
2
Scan ENTER/EXIT PROGRAMMING MODE
3
Scan SELECT CODE 93 LENGTH 1 SETTING
4
Scan Two Characters From
‘0’ and ‘1’
‘0’ and ‘7’
‘1’ and ‘5’
‘5’ AND ‘0’
5
Scan ENTER/EXIT PROGRAMMING MODE
$CC9L1
Select Code 93 Set Length 1 Setting
Make a mistake? Scan the CANCEL barcode to abort and
not save the entry string. You can then start again at the
beginning.
~
CANCEL
DEFAULT
01 = Length 1 is 1 Character
Содержание WDI4600
Страница 1: ...WDI4600 1D 2D Digital Scanner USB Product Reference Guide...
Страница 10: ...viii WDI4600 NOTES...
Страница 14: ...Introduction Programming the Reader 4 WDI4600 NOTES...
Страница 24: ...Setup Customizing Configuration Settings 14 WDI4600 NOTES...
Страница 28: ...Enter Exit Programming Mode Global Interface Features 18 WDI4600 NOTES...
Страница 212: ...Postal Code Selection 202 WDI4600 NOTES...
Страница 266: ...Standard Defaults 256 WDI4600 NOTES...
Страница 268: ...Sample Barcodes 258 WDI4600 Sample Barcodes continued Code 32 Codabar 13579 Code 93 Code 11 123456789...
Страница 272: ...Keypad 262 WDI4600 A B C D E F...
Страница 282: ...Scancode Tables 272 WDI4600 NOTES...
Страница 284: ...Wasp Barcode Technologies 1400 10th Street Plano Texas USA 75074 www waspbarcode com 820033790 Rev C December 2013...