background image

LED and Beeper Indications

26

Wasp WDI7500

Programming Mode

 - 

The following indications ONLY occur 

when the reader is in Programming Mode

.

INDICATION DESCRIPTION

LED

BEEPER

Label Pro-
gramming 
Mode Entry

A valid program-
ming label has 
been scanned.

LED blinks 
continuously

Reader sounds 
four low fre-
quency beeps.

Label Pro-
gramming 
Mode Rejec-
tion of Label

A label has been 
rejected.

N/A

Reader sounds 
three times at 
lowest fre-
quency and 
current vol-
ume.

Label Pro-
gramming 
Mode Accep-
tance of Par-
tial Label

In cases where 
multiple labels 
must be scanned 
to program one 
feature, this indica-
tion acknowledges 
each portion as it is 
successfully 
scanned.

N/A

Reader sounds 
one short beep 
at highest fre-
quency and 
current vol-
ume.

Label Pro-
gramming 
Mode Accep-
tance of Pro-
gramming

Configuration 
option(s) have been 
successfully pro-
grammed via labels 
and the reader has 
exited Program-
ming Mode.

N/A

Reader sounds 
one high fre-
quency beep 
and 4 low fre-
quency beeps 
followed by 
reset beeps.

Label Pro-
gramming 
Mode Cancel 
Item Entry

Cancel label has 
been scanned.

N/A

Reader sounds 
two times at 
low frequency 
and current 
volume.

Содержание Wasp WDI7500

Страница 1: ...Wasp WDI7500 2D Duraline USB Barcode Scanner Quick Reference Guide...

Страница 2: ...ike to make comments or suggestions about this or other Wasp Technologies publications please let us know via the Contact WaspTechnologies page Disclaimer Wasp Technologies has taken reasonable measur...

Страница 3: ...Keyboard Interface 8 Country Mode 9 Caps Lock State 13 Numlock 14 Programming 14 Using Programming Bar Codes 14 Configure Other Settings 15 Resetting Product Defaults 15 Reading Parameters 16 Good Rea...

Страница 4: ...ii WWS650...

Страница 5: ...without Wasp s prior written consent 1 3 Title to the licensed Software shall be and remain with Wasp or the third party from whom Wasp has obtained a license right This Agreement does not grant to En...

Страница 6: ...Y OR ANY OTHER BASIS EXCEED THE PRICE OR FEE PAID BY END USER FOR THE WASP PRODUCT UNDER NO CIRCUMSTANCES SHALL WASP OR ITS LICENSORS BE LIABLE TO END USER OR ANY THIRD PARTY FOR LOST PROFITS LOST DAT...

Страница 7: ...All notices required or authorized under this Agreement shall be given in writ ing and shall be effective when received with evidence of receipt Notices to Wasp shall be sent to the attention of Wasp...

Страница 8: ...orporated by reference in this clause The seat of the arbitration shall be Singapore The number of arbitrators will be three with each side to the dispute being entitled to appoint one arbitrator The...

Страница 9: ...werful omni direc tional reader the orientation of the symbol is not important Decoding Thanks to powerful algorithms WDI7500 reli ably decodes all major 1D linear barcodes 2D stacked codes such as PD...

Страница 10: ...the host device as shown The power can also be supplied through an external power supply via the Interface Cable supplied with a power jack Flash Memory Flash technology allows you to upgrade the WDI7...

Страница 11: ...the Front marking on the Cable Holder is facing out with the arrow pointing towards the front of the scanner 4 Insert the end of the cable into the socket of the Cable Holder 5 Push the Cover along th...

Страница 12: ...y the aiming system will be smaller when the reader is closer to the bar code and larger when it is farther from the code Symbologies with smaller bars or elements mil size should be read closer to th...

Страница 13: ...edge Information and programming options for each interface type are provided in this section Configuring the Interface Scan the appropriate programming bar code to selects the interface type for your...

Страница 14: ...e Interface Type 6 Wasp WDI7500 RS 232 RS 232 standard interface RS 232 RS 232 Wincor Nixdorf RS232 WN RS 232 for use with OPOS UPOS JavaPOS RS 232 OPOS USB USB Com to simulate RS 232 standard interfa...

Страница 15: ...ed USB OEM can be used for OPOS UPOS JavaPOS USB OEM a Download the correct USB Com driver from www waspbarcode com USB Keyboard with standard key encoding USB KBD USB Keyboard with alternate key enco...

Страница 16: ...er emulation for keyboard interfaces Keyboard Interface KEYBOARD WEDGE IBM AT or PS 2 PCs Standard Key Encoding KBD AT IBM AT or PS 2 PCs Standard Key Encoding without external keyboard KBD AT NK IBM...

Страница 17: ...ted by the keyboard This option is usable only with USB KBD and Keyboard Wedge interface without the Alternate Key mode COUNTRY MODE ENTER EXIT PROGRAMMING MODE Country Mode U S Country Mode Belgium C...

Страница 18: ...WDI7500 COUNTRY MODE continued Country Mode Czech Country Mode Denmark Country Mode France Country Mode French Canadian Country Mode Germany Country Mode Hungary Supports only the interfaces listed in...

Страница 19: ...Guide 11 COUNTRY MODE continued Country Mode Italy Country Mode Japanese 106 key Country Mode Lithuanian Country Mode Norway Country Mode Poland Country Mode Portugal Supports only the interfaces lis...

Страница 20: ...ype 12 Wasp WDI7500 COUNTRY MODE continued Country Mode Romania Country Mode Spain Country Mode Sweden Country Mode Slovakia Country Mode Switzerland Supports only the interfaces listed in the Country...

Страница 21: ...the format in which the reader sends character data This applies to keyboard wedge interfaces This does not apply when an alternate key encoding key board is selected ENTER EXIT PROGRAMMING MODE Caps...

Страница 22: ...rfaces section select other options and cus tomize your reader through use of the programming bar codes available in the WDI750 Using Programming Bar Codes This manual contains bar codes which allow y...

Страница 23: ...rogramming than the standard factory default settings refer to the PRG Resetting Product Defaults If you aren t sure what programming options are in your reader or you ve changed some options and want...

Страница 24: ...n time and if no code is decoded will switch on again before the next acquisition The illuminator will remain on until the symbol is decoded As you read code symbols adjust the distance at which you a...

Страница 25: ...Reading Parameters Quick Reference Guide 17 Digital Watermark Reading ENTER EXIT PROGRAMMING MODE Disable Enable...

Страница 26: ...desired multiple reads while in this mode Trigger Hold Multiple When the trigger is pulled scan ning starts and the product scans until the trigger is released or maximum scan on time 1 has elapsed Re...

Страница 27: ...motion is detected Motionix motion sensing technology Scan the Enter Exit Programming bar code above then either of the barcodes below ENTER EXIT PROGRAMMING MODE Scan Mode Trigger Single Scan Mode T...

Страница 28: ...ansmitted to the host It is active only while the scanner is in Trigger Single mode If the scanner switches to a different Read Mode Pick Mode is automatically dis abled Multiple Label Reading The rea...

Страница 29: ...cteristics User Environment and Regulatory infor mation Item Description PHYSICAL CHARACTERISTICS Dimensions Height 212 mm Length 110 mm Width 74 mm Weight without cable 330 gr without cable ELECTRICA...

Страница 30: ...ctance Resolution Max resolution 1D 4 mils Max resolution 2D 7 5 mils DEPTH OF FIELD TYPICAL A Symbology Working Ranges Code 39 4 mils 6 17 cm 20 mils 4 55 cm 40 mils 4 85 cm EAN 13 13 mils 4 48 cm PD...

Страница 31: ...st KIX Post Planet Code Postnet Royal Mail Code RM45CC IMB stacked codes including EAN JAN Composites GS1 Databar Composites GS1 Databar Expanded Stacked GS1 DataBar Stacked GS1 DataBar Stacked Omnidi...

Страница 32: ...and so may or may not be turned on For example certain indications such as the power up beep can be disabled using programming bar code labels ESD Level 20 KV Beeper Speaker 80 dB 10 cm REGULATORY Ele...

Страница 33: ...can ning Label Read Indicates that a host connection is not estab lished N A Reader chirps six times at the highest fre quency and cur rent volume Reader Active Mode The reader is active and ready to...

Страница 34: ...Pro gramming Mode Accep tance of Par tial Label In cases where multiple labels must be scanned to program one feature this indica tion acknowledges each portion as it is successfully scanned N A Reade...

Страница 35: ...eld Replaceable Unit isolation mode If the reader is reset the sequence will be repeated Press and release the trigger to hear the FRU indication code The following table describes the LED flashes bee...

Страница 36: ...uring scanning Use a soft dry cloth to clean the product If the product is very soiled clean it with a soft cloth moistened with a diluted non aggressive cleaning solution or diluted ethyl alcohol CAU...

Страница 37: ...warranty period shall extend from the date of shipment from Wasp for the duration published by Wasp for the product at the time of purchase Warranty period Wasp war rants repaired hardware devices ag...

Страница 38: ...apparatus iv any claimed defect or damage caused by the failure to provide proper maintenance including but not limited to cleaning the upper window in accordance with product manual v any defect or...

Страница 39: ...the carrier but Wasp shall not thereby assume any liability in con nection with the return shipment Ergonomic Recommendations Reduce or eliminate repetitive motion Maintain a natural position Reduce...

Страница 40: ...Services and Support 32 Wasp WDI7500...

Страница 41: ...Services and Support Quick Reference Guide 33...

Страница 42: ...Services and Support 34 Wasp WDI7500...

Страница 43: ......

Страница 44: ...es and the Wasp Technologies logo are registered trademarks of Wasp Barcode Technologies in many countries including the U S A and the E U Wasp Barcode Technologies 1400 10th Street Plano Texas USA 75...

Отзывы: