7.
SUCC
will be displayed to indicate a successful pairing. The operator will then
fully open then close one cycle. DO NOT press any buttons on the remote until
this cycle completes.
a. If a
FAIL
message is displayed, press
ENTER
on the remote to try to
pair again.
b. If a
FAIL
message is displayed again, ensure that the operator is in
pairing mode. If the red light is not still blinking, disconnect and
reconnect the battery connector on the operator and repeat steps 1-7
again.
MULTIPLE REMOTES
•
It is intended that one or multiple operators may be controlled from multiple secondary remotes. This is done by sending the
pairing and settings stored in the first configured
M
(main) remote, to the additional
S
(secondary) remote(s). Secondary
remotes will be 'copies' of the main.
•
Any changes to operator zones, ID numbers, and/or adding additional operators can only be performed using the main remote.
The changed settings would then need to be re-sent from the main to the secondary remote(s).
•
Ensure that a main remote has been configured as outlined in 'Remote Setup and Configuration' and that it has been paired to
the operator(s) as described in 'Paring Remote to Operator.'
Secondary Remote Configuration
•
All steps must be performed within 30 seconds or the remote control will default to the previous settings.
1. Open the remote battery cover; remove and reinstall two AA alkaline batteries and
replace the cover.
2. All the screen display segments will be visible while the remote runs a self-test which
lasts for a few seconds. After which,
SET
will be shown on the Display to indicate
input is required.
3. Press
▲ ▼
to choose either
C
(Celsius) or
F
(Fahrenheit).
4. Press
ENTER
to save your selection.
5. Press
▲ ▼
to choose either
M
(main) or
S
(secondary). Select
S
for secondary.
6. Press
ENTER
to save your selection.
7.
ZONE ALL