RAIN SENSOR 

The rain sensor should be installed horizontally, with a slight tilt to prevent water from pooling. The sensor location depends on many 
factors.  The key to proper installation is that the sensor must be 

level and exposed

 when the operator opens the unit.  The wires from 

the sensor to the operator must be ran to the operator in a water proof manner so as to not induce water penetration that could damage 
the interior. The sensor is not polarity sensitive so it does not matter which wire goes to which connector in the operator. 

By default, the rain sensor is enabled when the remote is initially paired to the operator regardless of whether the rain sensor is attached 
or not. When the rain sensor is enabled a small    umbrella will be displayed in the top right hand display box. 

1. To enable or disable the rain sensor, press any key to wake up the remote if the LCD 

display has powered off. 

2. Press

  MODE

3. Press

  ZONE

as necessary to choose the desired zone. 

4. After the desired zone is flashing, press

  ENTER

5.

MAX-OPEN

 will know be flashing. 

6. Press

▲ ▼

  until the    icon is displayed and flashing, press

  ENTER

7. Press

▲ ▼

  to choose the ID number (

1

 thru 

9

) within the zone. 

8. Press

  ENTER

to confirm your selection.  

9. Press

▲ ▼

 to choose between 

ON

 and 

OFF

 while they are flashing.  

10. Press

  ENTER

to save your setting.  

11. LCD displays steady 

ON

 or 

OFF

 for one second, then 

SUCC

 for 2 seconds, indicating 

success. Press 

  MODE

 a few times to return to the home screen 

a. If setting not successful, LCD displays 

FAIL

 for 1 second, then returns to the 

same step #8 to retry setting. 

RAIN SENSOR OPERATION 

When a drop of water is on the sensor the operator may not react immediately.  The control system actually takes multiple 
reading in an effort to avoid false readings and possible “cycling” of the operator before it sends the close or open commands. 

If the operator is  manually opened when the rain sensor is enabled AND there is  water present on the sensor, the 
operator will close and the    umbrella icon will blink on the Remote.

  If you desire to open the operator at this time, the 

sensor will need to be disabled before it will stay in the open position. 

If the Rain Sensor and the Automated Temperature Control are enabled at the same time, the Rain Sensor will take precedence 
over the Temperature Control.  In other words, if rain is detected, the operator will close regardless of the temperature until 
such time as water is no longer detected on the sensor before it will automatically re-open. 

As noted above, the rain sensor is designed to detect a lowering of the resistance between the metallic strips on the sensor.  The 
resistance can be lowered by a number of factors including moss, sap, heavy dew, or condensation drops from surrounding 
structures.  Therefore it is important to periodically clean the sensor to maintain proper operation.  If all operations function 
properly except when the Rain Sensor is enabled, cleaning the Rain Sensor is recommended.

Содержание Solar Smart GSVMS

Страница 1: ...ANUAL 800 388 0293 Fax 207 216 4562 csm wascoproducts com www wascoskylights com Eastern Facility 85 Spencer Drive Unit A Wells ME 04090 Western Facility 6645 Echo Avenue Reno NV 89506 with Rain Senso...

Страница 2: ...hment link on chain is fastened to the sash by a release pin 7 AC trickle charger included 8 Adaptable to awning and hopper windows and skylights Remote Highlights 1 Large and readable display with bi...

Страница 3: ...d bracket g bracket ket tabs UIRED ing the operator ing the chain clip ing the solar panel and bracket DO NOT INSTALL THE BATTERIES UNTIL DIRECTED TO DO SO Chain Clip Battery Cover Operator Battery AC...

Страница 4: ...up the remote if the LCD display has powered off 2 Press ZONE to choose a single zone 1 thru 9 of operators or ALL to operate all operators in all zones 3 Press OPEN or CLOSE to open or close the win...

Страница 5: ...Manual sion 8 12 2015 ON of the SOLAR PANEL and RAIN SENSOR panel must be mounted with airspace for cooling and performance efficiency as intain the product life span e solar panel face down on a fla...

Страница 6: ...ion 7 ZONE ALL and the temperature should now be displayed Installation and User Manual 7 Revision 8 12 2015 INITIAL REMOTE SETUP and CONFIGURATION The following are applicable for configuring the mai...

Страница 7: ...The remote will need to be paired within 2 minutes or the operator will default back to the previous settings 1 Remove the battery cover from the operator If connected disconnect the battery connecto...

Страница 8: ...operator zones ID numbers and or adding additional operators can only be performed using the main remote The changed settings would then need to be re sent from the main to the secondary remote s Ens...

Страница 9: ...from the main remote It will wait for 30 seconds 2 MAIN REMOTE STEPS a Press and hold MODE release when PAIR SET is displayed b Press MODE twice to move past RE ZONE to display M in the upper right c...

Страница 10: ...ON or OFF for one second then SUCC for 2 seconds indicating success Press MODE a few times to return to the home screen a If setting not successful LCD displays FAIL for 1 second then returns to the...

Страница 11: ...unction off 9 Press ENTER 10 ST is now displayed and flashing Press MODE to return to the home screen OR press to scroll and set other features 11 The Time To Close selection will be retained in memor...

Страница 12: ...e operator s is open The factory setting MAX OPEN limit is set to open up to 80 of full open position 1 Press any key to wake up the remote if the LCD display has powered off 2 Press MODE 3 Press ZONE...

Страница 13: ...Press ENTER 8 Press to set the desired temperature or NULL to turn function off for this zone 9 Press ENTER to save your selection The temperature in which the operator will run has now been set Next...

Страница 14: ...lar moment in time This measurement is highly variable and depends directly upon the level of sunlight on the solar panel Be aware of external influences which affect the light level these are directi...

Страница 15: ...hen PAIR SET is displayed 3 Press MODE again to display RE ZONE 4 Press ZONE as necessary to choose the appropriate zone 1 thru 9 of the operator to be moved to another zone 5 Press ENTER to save your...

Страница 16: ...se set MAX OPEN 4 Temperature change must be maintained for 10 minutes before the temperature control TC function will operate For more Trouble Shooting Tips please visit www SolarSmartOpener com ADVA...

Страница 17: ...se record your Remote settings for ease of reference as well as assist in troubleshooting ZONE ID Location 1 1 2 3 4 5 6 7 8 9 2 1 2 3 4 5 6 7 8 9 3 1 2 3 4 5 6 7 8 9 4 1 2 3 4 5 6 7 8 9 5 1 2 3 4 5 6...

Отзывы: