Figure 7.4
Example of lubricating oil system, dry oil sump (DAAE055758a)
Pipe connections
System components
Lube oil outlet
202
Heater (separator unit)
2E02
Lube oil to engine driven pump
203
Suction strainer (main lube oil pump)
2F01
Lube oil to priming pump
205
Suction filter (separator unit)
2F03
Lube oil from el.driven pump
208
Suction strainer (prelubricating oil pump)
2F04
Crankcase air vent
701
Suction strainer (stand-by pump)
2F06
Separator unit
2N01
Separator pump (separator unit)
2P03
Stand-by pump
2P04
Separator
2S01
Condensate trap
2S02
System oil tank
2T01
Sludge tank
2T06
7.3.1 Separation system
Separator unit (2N01)
Each main engine must have a dedicated lubricating oil separator and the separators shall be dimensioned
for continuous separating. If the installation is designed to operate on gas/MDF only, then intermittent
separating might be sufficient.
Product Guide Wärtsilä 34DF - 3/2012
73
Product Guide
7. Lubricating Oil System