The above equipment is built on a steel frame, which can be welded or bolted to its foundation in the ship.
The unit has all internal wiring and piping fully assembled. All HFO pipes are insulated and provided with
trace heating.
Figure 6.13
Feeder/booster unit, example (DAAE006659)
Fuel feed pump, booster unit (1P04)
The feed pump maintains the pressure in the fuel feed system. It is recommended to use a screw pump as
feed pump. The capacity of the feed pump must be sufficient to prevent pressure drop during flushing of
the automatic filter.
A suction strainer with a fineness of 0.5 mm should be installed before each pump. There must be a positive
static pressure of about 30 kPa on the suction side of the pump.
Design data:
Total consumption of the connected engines added with the
flush quantity of the automatic filter (1F08)
Capacity
1.6 MPa (16 bar)
Design pressure
0.7 MPa (7 bar)
Max. total pressure (safety valve)
100°C
Design temperature
Product Guide Wärtsilä 34DF - 3/2012
63
Product Guide
6. Fuel System