For Installations where no Chimney exists:
The Connecting flue pipe from the Stove should connect to the Twin Wall Insulated flue
pipe, ensure this flue pipe is the correct type for Multi-Fuel applications. The HT-Plus flue
pipe manufactured by Midtherm is suitable and available from WARRIOR Stoves dealers.
This flue pipe requires a minimum 50mm clearance from combustible materials and should
not be joined in a wall or floor. Where this flue pipes passes through a combustible floor a
ventilated fire stop kit must be used.
Some typical installations are shown as following: