WARRIOR Stoves WSDAID Скачать руководство пользователя страница 19

STOVE AND CHIMNEY MAINTENANCE 

 

Chimney/Flueway Sweeping: 
 
The entire chimney/flueway should be swept frequently from top to bottom to keep clean 
and prevent the build up of the products of combustion.  The frequency required is difficult 
to gauge due to the nature of varying flue conditions and fuels burnt, we therefore suggest 
that the chimney is swept within the first 4 to 6 weeks of use to reasonably establish the  
frequency required.  In any case the chimney/flueway should be swept at least twice a year, 
generally best before and after the main winter burning season.  The sweeping should be 
done by a competent and qualified chimney engineer, a member of the National Association 
of Chimney Sweeps (N.A.C.S.), Guild of Master Sweeps or The Association of                
Professional & Independent Chimney Sweeps Ltd (APICS).  They will provide a certificate 
for sweeping and their details are listed at the rear of this manual under useful addresses.  
The chimney/flueway should be inspected for blockage prior to lighting after a prolonged 
period of not being used.  Numerous chemical chimney cleaners are available to help reduce 
the build up of the products of combustion.  Ensure  the cleaner is suitable for the intended 
chimney type as many are not suitable for use with Stainless Steel flues and liners due to 
their highly corrosive nature.  The flue cleaner available from your WARRIOR Stoves 
dealer supplied by WARRIOR Stoves is suitable for all chimney/flue types.  Follow the 
manufacturers instructions with regards to usage. 
 
Stove Maintenance: 
 
Internal: 
 
The frequency required for cleaning your stove will vary considerably dependant upon usage 
and fuel type.  The inside of the stove should be cleaned at least Monthly during peak usage 
to remove any build up of deposits from the products of combustion, experience will advise 
whether this needs doing more or less often.  It is advisable to wear goggles or safety glasses 
as well as a dust mask and protective gloves when cleaning. 
Use a stiff brush combined with a vacuum cleaner and start at the top underside of the stove 
and work down to the bottom.  Particular attention should be given to cleaning above the 
baffle plate and the air inlet controls which are both important and often get overlooked.  
Your stove should be inspected every year by a competent person who should thoroughly 
strip down and clean the inside of the stove as well as visually checking components.   
Damaged or broken parts should immediately be repaired or replaced with authorised spares, 
your WARRIOR Stoves dealer will be able to obtain these for you.  The use of spare parts 
not supplied by WARRIOR Stoves may invalidate the stove guarantee.  
  
External: 
The outer surface of the stove body can periodically be cleaned as required with a soft dry 
brush.  When the stove surface needs retouching or rejuvenating use high temperature  
resistant paint available from your WARRIOR Stoves dealer.  The paint is available in liquid 
or aerosol form, both are easy to use but ensure the manufacturers instructions are strictly 
adhered to.  The rope door seals need constant checking to ensure there is an air tight seal 
between the door and the main body of the stove.  If the rope comes loose then it is easy to 
stick back with stove rope adhesive or it may need replacing if it has frayed or started to  
disintegrate.  The high temperature resistant adhesive and rope will be available from your 
WARRIOR Stoves dealer. 
 
 

17 

Содержание WSDAID

Страница 1: ...lly and thoroughly read this manual prior to any installation or lighting of your new stove If you have any questions regarding this stove which are not mentioned in this manual then please contact th...

Страница 2: ...ALLATION Including Chimney Guidance 5 12 STOVE OPERATION 13 16 STOVE AND CHIMNEY MAINTENANCE 17 18 TROUBLESHOOTING 19 PARTS DIAGRAM 20 LIST OF USEFULADDRESS S 21 INSTALLATION RECORD 22 MAINTENANCE REC...

Страница 3: ...entre of flue mm 130 Flue Diameter Req mm 150 Net weight Kg 210 Gross weight Kg Packed 220 Minimum distance to Combustible surfaces Top 800mm Side 450mm Rear 1200mm Type of boiler and method of constr...

Страница 4: ...this manual for further reference Most stove retailers will be able to assist in advising a competent person for installation WARRIOR Stoves installation instructions cannot be taken as conforming to...

Страница 5: ...ed chimney or flueway It is not suitable for installing into a shared flueway The stove must always have a permanent free air supply into the room it is being installed into For Stoves rated above 5KW...

Страница 6: ...ve which require fixing these parts should be The Legs the Stove Outlet and the Stove Outlet Blanking Plate and the Handles These parts should be easily identifiable from the exploded parts diagram li...

Страница 7: ...d into an existing chimney ensure that protective eye ware is worn during inspection and whilst attending to any remedial work that may be required In the case of installing into old Chimneys particul...

Страница 8: ...ear of the stove the maximum horizontal run should not exceed 150mm Provision must be made for cleaning the entire length of the chimney flue other than through the stove The Flue way must be kept war...

Страница 9: ...lems with the chimney draw The connecting flue pipe must be sealed to the chimney with fire cement and high temperature resistant rope as required This is usually done into a register Blanking plate w...

Страница 10: ...tant board The Flue Pipe must be 3 times it s diameter away from combustible materials For example 150mm Flue Pipe must be 450mm away from combustible materials FLUE Sealed door to access chimney for...

Страница 11: ...here this flue pipes passes through a combustible floor a ventilated fire stop kit must be used Some typical installations are shown as following Rain cap Cowl 600mm minimum One load bearing support e...

Страница 12: ...ast 1000mm above the highest point of intersection of the chimney and the weather surface or B at least as high as the ridge C Below on a pitched roof or within 2300mm hori zontally to an open able ro...

Страница 13: ...solid fuel appliance or open fire appliance fitted at the base or the bottom of the chimney heat the inside of the Appliance Fireplace chamber with a blow Lamp gas stove or similar device for approx...

Страница 14: ...hat cannot be harmed by heat in the opening at the base of the flue or in the appliance if it is fitted Always follow the pellet manufacturer s safety instructions Ignite pellet and open all vents to...

Страница 15: ...ost important It should be readily identified by the parts diagram and is located on the lower section of the stove Air enters the stove by this control and it is the amount of air allowed to enter th...

Страница 16: ...ron and should be seasoned Seasoning is the process of gradually warming through the castings of the stove to allow all components to heat up and cool down together without causing any damage to the s...

Страница 17: ...st NOT be used in your stove the use of such fuel will invalidate your guarantee as will the use of smaller sized fuels that can clog the grate Fuels which have a maximum dimension of less than 35mm a...

Страница 18: ...should be regulated similarly to the air inlet controls the further closed then the slower the fire burn rate will be Observe the note in the Air control section regarding use of damper whilst the sto...

Страница 19: ...dependant upon usage and fuel type The inside of the stove should be cleaned at least Monthly during peak usage to remove any build up of deposits from the products of combustion experience will advis...

Страница 20: ...and any fragments Penetrating oil may assist in removing the machine screws if they are proving difficult to undo If the rope seal that the glass rests on is undamaged then the glass can be placed on...

Страница 21: ...that require attention Ensure the procedures in the Stove and Chimney Maintenance section are adhered to During operation nominal fume and smoke emission may occur when refuelling or emptying the ash...

Страница 22: ...Top Outlet Connecting Plate 15 Tertiary Air burn Plate 16 Back Boiler 17 Flue Blanking Plate Rear 18 Refractory Fire Brick 19 Left Plate 20 Baffle Plate Lower Section 31 Door Handle Catch 32 Door Han...

Страница 23: ...of Master Sweeps The Bungalow London Road Attleborough Norfolk NR17 2DE T 01953 451322 W www guild of master sweeps co uk E contactus guild of master sweeps co uk Solid Fuel Association 7 Swanwick Cou...

Страница 24: ...imney Sweeps Ltd APIC Bryallen Hengar Road St Tudy Bodmin Cornwall PL30 3PL T 0845 604 4327 Water Regulations Advisory Scheme Fern Close Pen Y Fan Industrial Estate Oakdale Gwent NP11 3EH T 01495 2484...

Страница 25: ...spection and testing after completion Tests carried out by Tests Appx E in AD J 2002 ed and results Flue visual Inspection sweeping coring ball smoke Appliance where included spillage 1 Building addre...

Страница 26: ...me Address Registered Member of Work Conducted Installation Chimney Safe Y N Sign Name Print Please kindly ensure this Maintenance Record is completed by the engineer every time work is completed on e...

Страница 27: ...ARRIOR Stoves Ltd The stove dealer will require the model receipt invoice the installation and service records your full contact details description of the fault and the fuel type brand used where app...

Страница 28: ...nge of products please visit our website at WWW WARRIORSTOVES CO UK WWW WARRIORSTOVES CO UK WWW WARRIORSTOVES CO UK WWW WARRIORSTOVES CO UK OR E mail us to find your nearest stockist at info warriorst...

Отзывы: