background image

-11- 

 

 

 

 

 

 

 

8. Appendix and Suggestions 

1. Storage 

It  is  necessary  to  store the  generator  in  correct way  to  keep  generator  in  good 

condition.  Following  steps  are  to  protect  the  generator  from  rust  and  corrosion 

which would damage its performance and appearance. 

 

Cleaning

 

If  the  generator  has  just  run  over, clean  it  after cooling  at  least  2  hours.  Then 

clean  the  surface  of  generators,  paint  the  damage  part,  and  coat  with  a  thin 

layer of film. 

 

Fuel

 

Diesel  fuel  deteriorates  during  storage,  which  will  make  the  starting  of  the 

generator  more  difficult  and  produce  glue  materials  that  would  clog  the  fuel 

system.  It  is  necessary  to  clean  or  replace  the  fuel  system  if  diesel  fuel 

deteriorates during storage. 

2. Storage instructions 

① 

Do  not  touch  the  muffler.  Around  the  exhaust  port  of  the  muffler  is  very  hot    

while  generator  is  running  and  the  heat  will  remain  for  some  time  after 

generator  stops.  To  prevent  burn  or  fire,  do  not  move  the  generator  into  the 

storage room until it is cooled. 

② 

Storage  room  should  be  of  good  ventilation  and  far  from  fire  place  like  stove, 

water heater, dryer, etc, in order to avoid possible serious injury and damage to 

equipment. Storage room should not be in the wet areas which would cause the 

generator rust and corrosion. 

 

Put the generator on a level surface as tilting may cause fuel or oil leaks. 

3. Transport 

① 

If the generator has just run over, please do the shipment after cooling two hours 

because  the  exhausting  system  is  still  very  hot  which  may  burn  you  or  cause  a 

fire. 

 

Put the generator on a level surface while shipping to prevent leaking the oil. 

Содержание LDG12S

Страница 1: ...WARRIOR GENERATORS USER MANUAL FOR MODELS LDG12S LDG12S3...

Страница 2: ...Before Start DG12 Check Before Operation 5 DG12S Check Before Operation 6 5 Operation 7 6 Stopping Generator 7 7 Maintenance DG12 Check and Maintenance DG12S Check and Maintenance 9 10 8 Appendix and...

Страница 3: ...tion while the generator set is shut down and isolated Diesel Fuel is combustible and can ignite Do not overfill the fuel tank fill to recommended level on gauge Make sure the fuel cap is tightly secu...

Страница 4: ...Brushless AC single phase Brush AC three phase Frequency Hz 50 60 Voltage V 110 115 120 220 230 240 110 220 115 230 120 240 220 380 230 400 110 115 120 220 230 240 110 220 115 230 120 240 220 380 230...

Страница 5: ...on Quantity 1 Top cover 1 2 Frame 1 3 Engine side cover 1 4 Front cover 1 5 Muffler assy 1 6 Air cleaner assy 1 7 Engine 1 8 Shock absorber 6 9 Lock wheel 2 10 Alternator 1 11 Wheel 2 12 Control panel...

Страница 6: ...1 7 Rubbe rcover 1 8 Alternator clapboard 1 9 Alternator 1 10 Muffler heat insulation cover 1 11 Muffler assy 1 12 Engine 1 Item Description Quantity 13 Muffler assy 1 14 Shock absorber 6 15 Battery 1...

Страница 7: ...s lower limit when take out the ways of adding oil as below 7 1 Finally install and plug oil gauge Notice DO NOT run generator with low oil level or below Minimum this will cause generator engine part...

Страница 8: ...r engine parts to damage 2 Fuel level Caution Please refuel in a well ventilated area make sure there is NO cigarettes naked flames or sparks when refuel Open left door check the fuel level indicator...

Страница 9: ...esn t start please wait for about 30 seconds OFF ON before attempting to start again 3 AC application In accordance with the actual situation to connect the load through the load terminals or wiring s...

Страница 10: ...e The first month or 20 hours Every three months or 100 hours Every three months or 100 hours Oil Check Renew First time Second time Air cleaner element Check Clean The valve gap Check adjust The liqu...

Страница 11: ...rain plug back Open the lock over the front cover 4 1 screw the cylinder head oil cap 2 as the photo pull the oil until reach the oil gauge max limited 4 1 in the end screw back the cylinder head stud...

Страница 12: ...lace drain plug back Move the plastic rounded lid on the top of genset unscrew the cylinder head oil cap fill the oil until reach the oil gauge max limited 4 1 in the end screw back the cylinder head...

Страница 13: ...storage 2 Storage instructions Do not touch the muffler Around the exhaust port of the muffler is very hot while generator is running and the heat will remain for some time after generator stops To pr...

Страница 14: ...n or rings in wrong place Change and adjust piston ring Valve clearance is not correct Adjust the clearance as per operational manual Bolts of cylinder head are not tight Re tight the bolt Check fuel...

Страница 15: ...13 10 Electrical Wiring Diagram Single Phase Generator 11 Electrical Wiring Diagram Three Phase Generator...

Отзывы: