background image

hdf3dl2sm-rev1218

sandpiperpump

.

com

Model Model HDF3M/HDF4M  • 

5

Explanation of Pump Nomenclature

ATEX Detail

Wet End Materials 

A    

Neoprene/Urethane

 

Nitrile

 

K

    Neoprene/Hytrel

 

N

  Neoprene

 

S

  Santoprene

Design Level 

2

Construction

 

II 

 Cast Iron Wetted, Cast Iron Air

Options 

P0

    10-30 VDC Pulse Output Kit

 

P1

    Intrinsically Safe ATEX Compliant 

 

 

  Pulse Output

 

P2

    110/120 or 220/240 VAC Pulse output Kit

 

 

Pump Series 

HD

  Heavy Duty

Pump Design 

F

  Flap

Pump Size 

3M  

 3" 150# ANSI Style Flange

 

4M  

 4" 150# ANSI Style Flange

Discharge Porting Position 

Top Suction / Bottom Discharge

Your Serial #: 

(fill in from pump nameplate)

 _____________________________________

  __ __ 

_____ 

__ ___ __ __ __

  Pump 

Pump 

Pump 

Options 

Discharge  Diaphragm/  Design   Construction

 

  Series 

Design 

Size 

 

Porting 

Valve 

Level

 XX X 

XXXX, 

X XX X XX X

Model #:

(fill in from pump  

nameplate)

Your Model #:

ATEX Details

Wetted 

Material 

Options

Non-Wetted 

Material 

Options

Pump 

Options

Kit 

Options

II 1 G Ex h IIC T5...225°C (T2) Ga 

II 1D Ex h IIIC T100°C...T200°C Da 

I M1 Ex h I Ma

H, S

C

6

00

II 2 G Ex h IIC T5...225°C (T2) Gb 

II 2 D Ex h IIIC T100°C...T200°C Db

A, H, S

A, C, Y

**0, 6

00

II 2 G Ex h ia IIC T5 Gb

II 2 D Ex h ia IIIC T100°C Db

A, H, S

A, C, Y

**0, 6

P1

II 2 G Ex h mb IIC T5 Gb

II 2 D Ex h mb tb IIIC T100°C Db

A, H, S

A, C, Y

**0, 6

A1, A2, A3, A4

S05 M

ATEX Details

Wetted 

Material 

Options

Non-Wetted 

Material 

Options

Pump 

Options

Kit 

Options

II 1 G Ex h IIC T5...225°C (T2) Ga 

II 1D Ex h IIIC T100°C...T200°C Da 

I M1 Ex h I Ma

H, I, S

I, Z

6

00

II 2 G Ex h IIC T5...225°C (T2) Gb 

II 2 D Ex h IIIC T100°C...T200°C Db A, H, I, S, X

A, I, Y, Z

6

00

II 2 G E x h ia IIC T5 Gb

II 2 D Ex h ia IIIC T100°C Db

A, H, I, S, X

A, I, Y, Z

6

P1

II 2 G Ex h mb IIC T5 Gb

II 2 D Ex h mb tb IIIC T100°C Db

A, H, I, S, X

A, I, Y, Z

6

A1, A2, A3, A4

S1F M, M1F Remove wetted material option X

**Pump option 0 is only ATEX compliant with non-wetted material option C

ATEX Details

Wetted 

Material 

Options

Non-Wetted 

Material 

Options

Pump 

Options

Kit 

Options

II 1 G Ex h IIC T5...225°C (T2) Ga 

II 1D Ex h IIIC T100°C...T200°C Da 

I M1 Ex h I Ma

H, I, S

I, S, Z

6

00

II 2 G Ex h IIC T5...225°C (T2) Gb 

II 2 D Ex h IIIC T100°C...T200°C Db A, H, I, S, X A, I, S, Y, Z

6

00

II 2 G Ex h ia IIC T5 Gb

II 2 D Ex h ia IIIC T100°C Db

A, H, I, S, X A, I, S, Y, Z

6

P1

II 2 G Ex h mb IIC T5 Gb

II 2 D Ex h mb tb IIIC T100°C Db

A, H, I, S, X A, I, S, Y, Z

6

A1, A2, A3, A4

S15,S20,S30 M

ATEX Details

Wetted 

Material 

Options

Non-Wetted 

Material 

Options

Pump 

Options

Kit 

Options

II 1 G Ex h IIC T5...225°C (T2) Ga 

II 1D Ex h IIIC T100°C...T200°C Da 

I M1 Ex h I Ma

C, V

C

6

00

II 2 G Ex h IIC T5...225°C (T2) Gb 

II 2 D Ex h IIIC T100°C...T200°C Db

C, V

C

0, 6

00

II 2 G Ex h ia IIC T5 Gb

II 2 D Ex h ia IIIC T100°C Db

C, V

C

0, 6

P1

II 2 G Ex h mb IIC T5 Gb

II 2 D Ex h mb tb IIIC T100°C Db

C, V

C

0, 6

A1, A2, A3, A4

S05, S1F NM

ATEX Details

Wetted 

Material 

Options

Non-Wetted 

Material 

Options

Pump 

Options

Kit 

Options

I 1 G Ex h IIC T5...225°C (T2) Ga 

II 1D Ex h IIIC T100°C...T200°C Da 

I M1 Ex h I Ma

C

C

6

00

II 2 G Ex h IIC T5...225°C (T2) Gb 

II 2 D Ex h IIIC T100°C...T200°C Db

C

C

0, 6

00

II 2 G Ex h ia IIC T5 Gb

II 2 D Ex h ia IIIC T100°C Db

C

C

0 ,6

P1

II 2 G Ex h mb IIC T5 Gb

II 2 D Ex h mb tb IIIC T100°C Db

C

C

0 ,6

A1, A2, A3, A4

S15,S20 NM

ATEX Details

Construction  Options

II 2 G Ex h IIC T5...225°C (T2) Gb 

II 2 D Ex h IIIC T100°C...T200°C Db

CA

00

II 2 G Ex h ia IIC T5 Gb

II 2 D Ex h ia IIIC T100°C Db

CA

P1

PB1/4

ATEX Details

Wetted 

Material 

Options

Non-Wetted 

Material 

Options

II 1 G Ex h IIC T5...225°C (T2) Ga 

II 1D Ex h IIIC T100°C...T200°C Da 

I M1 Ex h I Ma

S

S, T, 7, 8, 9

II 2 G Ex h IIC T5...225°C (T2) Gb 

II 2 D Ex h IIIC T100°C...T200°C Db All Options

All Options

G15, G20, G30

ATEX Details

Construction

Options

II 1 G Ex h IIC T5...225°C (T2) Ga 

II 1D Ex h IIIC T100°C...T200°C Da 

I M1 Ex h I Ma

II, SI, HI

N/A

II 2 G Ex h IIC T5...225°C (T2) Gb 

II 2 D Ex h IIIC T100°C...T200°C Db A, CI, II, HI, HC, SI, SS

P1

ST1 1/2

ATEX Details

Construction

Options

II 1 G Ex h IIC T5...225°C (T2) Ga 

II 1D Ex h IIIC T100°C...T200°C Da 

I M1 Ex h I Ma

II, SI

00

II 2 G Ex h IIC T5...225°C (T2) Gb 

II 2 D Ex h IIIC T100°C...T200°C Db

A, I, SI, SS

00

II 2 G Ex h ia IIC T5 Gb

II 2 D Ex h ia IIIC T100°C Db

A, I, II, SI, SS

P1

ATEX Details

Construction

Options

II 1 G Ex h IIC T5...225°C (T2) Ga 

II 1D Ex h IIIC T100°C...T200°C Da 

I M1 Ex h I Ma

 SI, HI

00

II 2 G Ex h IIC T5...225°C (T2) Gb 

II 2 D Ex h IIIC T100°C...T200°C Db

A, SI, SS, HC, HI

00

II 2 G Ex h ia IIC T5 Gb

II 2 D Ex h ia IIIC T100°C Db

A, HC, HI, SI, SS

P1

HDF1, HDF2

SB1, SA1

ATEX Details

Construction

Options

II 1 G Ex h IIC T5...225°C (T2) Ga 

II 1D Ex h IIIC T100°C...T200°C Da 

I M1 Ex h I Ma

II

00

II 2 G Ex h ia IIC T5 Gb

II 2 D Ex h ia IIIC T100°C Db

II

P1

HDF3M

ATEX Details

Construction

Options

II 1 G Ex h IIC T5...225°C (T2) Ga 

II 1D Ex h IIIC T100°C...T200°C Da 

I M1 Ex h I Ma

CI, SI

00

II 2 G Ex h ia IIC T5 Gb 

II 2 D Ex h ia IIIC T100°C Db

CI, SI

P1

HDB3

ATEX Details

Construction

Options

II 1 G Ex h IIC T5...225°C (T2) Ga 

II 1D Ex h IIIC T100°C...T200°C Da 

I M1 Ex h I Ma

 SI, HI, II

00

II 2 G Ex h IIC T5...225°C (T2) Gb 

II 2 D Ex h IIIC T100°C...T200°C Db

A, CI, SS, HC

00

II 2 G Ex h ia IIC T5 Gb

II 2 D Ex h ia IIIC T100°C Db

A, CI, II, HI, HC, SI, SS

P1

HDB2

ATEX Details

Construction

Options

II 1 G Ex h IIC T5...225°C (T2) Ga 

II 1D Ex h IIIC T100°C...T200°C Da 

I M1 Ex h I Ma

 SI, II

00

II 2 G Ex h IIC T5...225°C (T2) Gb 

II 2 D Ex h IIIC T100°C...T200°C Db

A, CI, SS

00

II 2 G Ex h ia IIC T5 Gb

II 2 D Ex h ia IIIC T100°C Db

A, CI, II, SI, SS

P1

HDB1

ATEX Details

Construction

Options

II 1 G Ex h IIC T5...225°C (T2) Ga 

II 1D Ex h IIIC T100°C...T200°C Da 

I M1 Ex h I Ma

II, SI

00

II 2 G Ex h IIC T5...225°C (T2) Gb 

II 2 D Ex h IIIC T100°C...T200°C Db

A, I, SI, SS

00

HDF3A

MODEL SPECIFIC

1: PUMP

 SPECS

Содержание SANDPIPER Signature Series

Страница 1: ...ain St Mansfield Ohio 44902 USA Telephone 419 524 8388 Fax 419 522 7867 SANDPIPERPUMP COM Copyright 2017 Warren Rupp Inc All rights reserved Certified Quality ISO 9001 Certified ISO 14001 Certified SE...

Страница 2: ...ARNING The use of non OEM replacement parts will void or negate agency certifications including CE ATEX CSA 3A and EC1935 compliance Food Contact Materials Warren Rupp Inc cannot ensure nor warrant no...

Страница 3: ...0 C to 50 C 20 C to 100 C T5 T100 X Ambient Temperature Range C Process Temperature Range C 20 C to 60 C 20 C to 150 C 1 Per CSA standards ANSI LC6 2018 US Canadian Technical Letter R14 G Series Natur...

Страница 4: ...SECTION 3 EXPLODED VIEW 7 Composite Repair Parts Drawing Composite Repair Parts List Material Codes SECTION 4 AIR END 10 Air Distribution Valve Assembly Air Valve with Stroke Indicator Assembly Pilot...

Страница 5: ...a I M1 Ex h I Ma II SI HI N A II 2 G Ex h IIC T5 225 C T2 Gb II 2 D Ex h IIIC T100 C T200 C Db A CI II HI HC SI SS P1 ST1 1 2 ATEX Details Construction Options II 1 G Ex h IIC T5 225 C T2 Ga II 1D Ex...

Страница 6: ...ene Fluoride A durable fluoroplastic with excellent chemical resistance Excellent for UV applications High tensile strength and impact resistance 250 F 121 C 0 F 18 C Santoprene Injection molded therm...

Страница 7: ...l Tolerance 125 3mm 2X 7 50 191 15 93 405 2X 6 00 152 8X 75 19 2X 2 00 51 32 31 821 30 31 770 AIR INLET 3 4 NPT FEMALE 13 13 333 14 63 371 7 06 179 5 30 135 10 38 264 11 63 295 2X 3 00 76 4X 56 14 3 7...

Страница 8: ...5 06 129 15 93 405 26 56 675 16 19 411 SUCTION PORT 4 150 ANSI STYLE FLANGE DISCHARGE PORT 4 150 ANSI STYLE FLANGE 7 06 179 5 30 135 13 13 333 10 38 264 14 63 371 11 63 295 4X 56 14 2X 3 00 76 EXHAUS...

Страница 9: ...ections are controlled by the check valves ball or flap orientation The pump primes as a result of the suction stroke The suction stroke lowers the chamber pressure P3 increasing the chamber volume Th...

Страница 10: ...ycle erratically or stop operating Water in the air supply can be reduced by using a point of use air dryer Air Inlet and Priming To start the pump slightly open the air shut off valve After the pump...

Страница 11: ...int of use air drier Clogged manifolds Clean manifolds to allow proper air flow Deadhead system pressure meets or exceeds air supply pressure Increase the inlet air pressure to the pump Pump is design...

Страница 12: ...60 022 360 35 570 002 360 36 570 010 XXX 37 612 090 010 38 612 124 010 39 618 003 330 40 620 011 114 41 670 006 000 42 685 041 120 43 720 004 360 44 722 007 115 45 807 016 330 46 807 017 330 47 807 01...

Страница 13: ...Sealing 4 26 360 041 379 Gasket Pilot Valve 1 27 360 048 425 Gasket Air Valve 1 28 518 045 010 Manifold 2 29 530 033 000 Muffler Metal 1 30 545 007 330 Nut Hex 7 16 14 20 31 545 008 330 Nut Hex 1 2 1...

Страница 14: ...Conductive Neoprene 385 Conductive EPDM 408 Cork and Neoprene 425 Compressed Fibre 426 Blue Gard 440 Vegetable Fibre 500 Delrin 500 502 Conductive Acetal ESD 800 503 Conductive Acetal Glass Filled 506...

Страница 15: ...id factory warranty 1 A 1 B 1 B 1 C 1 E 1 F 1 G 1 C 1 E 1 F 1 G 1 D Air Distribution Valve Servicing See repair parts drawing remove screws Step 1 Remove Hex Head Cap Screws 1 G Step 2 Remove end cap...

Страница 16: ...ol 2 3 F 675 037 080 Retaining Ring 1 3 A 3 F 3 D 3 B 3 C 3 E Pilot Valve Servicing With Pilot Valve removed from pump Step 1 Remove snap ring 3 F Step 2 Remove sleeve 3 B inspect O Rings 3 C replace...

Страница 17: ...together Torque values are called out on the exploded view Repeat procedure for second side assembly Allow a minimum of 15 minutes to elapse after torquing then re torque the assembly to compensate f...

Страница 18: ...N809 2012 Pumps and Pump Units for Liquids Common Safety Requirements to verify conformance 5 YEAR Limited Product Warranty Warren Rupp Inc Warren Rupp warrants to the original end use purchaser that...

Страница 19: ...ies U Series F Series T Series EH Series SH Series GH Series Conductive plastic pump models with integral muffler S Series PB Series Tranquilizer surge suppressors Hazardous Location Applied I M1 Ex h...

Отзывы: