background image

f15mdl1sm-rev0219

sandpiperpump

.

com

2

 • Model F15 Metallic 

IMPORTANT

Read the safety warnings and instructions in this manual 

before pump installation and start-up. Failure to comply with 

the recommendations stated in this manual could damage the 

pump and void factory warranty.

When used for toxic or aggressive fluids, the pump should 

always be flushed clean prior to disassembly.

Airborne particles and loud noise hazards. Wear eye and ear 

protection.

Before maintenance or repair, shut off the compressed air line, 

bleed the pressure, and disconnect the air line from the pump. 

Be certain that approved eye protection and protective clothing 

are worn at all times. Failure to follow these recommendations 

may result in serious injury or death.

When the pump is used for materials that tend to settle out 

or solidify, the pump should be flushed after each use to 

prevent damage. In freezing temperatures the pump should be 

completely drained between uses.

Before pump operation, inspect all fasteners for loosening 

caused by gasket creep. Retighten loose fasteners to prevent 

leakage. Follow recommended torques stated in this manual.

CAUTION

WARNING

Nonmetallic pumps and plastic components are not UV 

stabilized.  Ultraviolet radiation can damage these parts and 

negatively affect material properties. Do not expose to UV light 

for extended periods of time.

In the event of diaphragm rupture, pumped material may enter 

the air end of the pump, and be discharged into the atmosphere. 

If pumping a product that is hazardous or toxic, the air exhaust 

must be piped to an appropriate area for safe containment.

This pump is pressurized internally with air pressure 

during operation. Make certain that all fasteners and piping 

connections are in good condition and are reinstalled properly 

during reassembly.

Take action to prevent static sparking. Fire or explosion can 

result, especially when handling flammable liquids. The pump, 

piping, valves, containers and other miscellaneous equipment 

must be properly grounded.

Safety Information

WARNING

Pump not designed, tested or certified to be powered by 

 

compressed natural gas. Powering the pump with natural  

gas will void the warranty.

Use safe practices when lifting

kg

WARNING

The use of non-OEM replacement parts will void (or negate) 

agency certifications, including CE, ATEX, CSA, 3A and EC1935 

compliance (Food Contact Materials).  Warren Rupp, Inc. cannot

 

ensure nor warrant non-OEM parts to meet the stringent 

requirements of the certifying agencies. 

ATEX Pumps - Conditions For Safe Use

1. 

 

Ambient temperature range is as specifi ed in tables 1 & 2 on the next page

2.  

ATEX compliant pumps are suitable for use in explosive atmospheres when the equipment is properly grounded in  

   

accordance with local electrical codes

3. 

 

Conductive Polypropylene, conductive Acetal or conductive PVDF pumps are not to be installed in applications where the  

   

pumps may be subjected to oil, greases and hydraulic liquids.

4. 

 

When operating pumps equipped with non-conductive diaphragms that exceed the maximum permissible projected area,  

   

as defi ned in EN ISO 80079-36 : 2016 section 6.7.5 table 8, the following protection methods must be applied

   

- Equipment is always used to transfer electrically conductive fl uids or 

   

- Explosive environment is prevented from entering the internal portions of the pump, i.e. dry running.

Содержание SANDPIPER F15

Страница 1: ...it of IDEX Corporation 800 N Main St Mansfield Ohio 44902 USA Telephone 419 524 8388 Fax 419 522 7867 SANDPIPERPUMP COM Copyright 2017 Warren Rupp Inc All rights reserved Certified Quality ISO 9001 Ce...

Страница 2: ...n appropriate area for safe containment This pump is pressurized internally with air pressure during operation Make certain that all fasteners and piping connections are in good condition and are rein...

Страница 3: ...to 108 C T4 T135 C 20 C to 160 C T3 T200 C 20 C to 177 C 225 C T2 Table 1 Category 2 ATEX Rated Pumps Ambient Temperature Range C Process Temperature Range C 20 C to 60 C 20 C to 150 C Table 2 Catego...

Страница 4: ...OPERATION 9 Principle of Pump Operation Recommended Installation Guide Troubleshooting Guide SECTION 3 EXPLODED VIEW 12 Composite Repair Parts Drawing Service Repair Kits Composite Repair Parts List...

Страница 5: ...Stainless Steel Diaphragm Check Valve Materials D FDA Santoprene FDA Santoprene H FDA Hytrel FDA Hytrel K PTFE with FDA Hytrel Backer PTFE Z PTFE One Piece Bonded Fusion Diaphragm PTFE Your Serial fil...

Страница 6: ...viations in excess of 5 NOTE Performance based on the following elastomeric fitted pump flooded suction water at ambient conditions The use of other materials and varying hydraulic conditions may resu...

Страница 7: ...n EPDM Shows very good water and chemical resistance Has poor resistance to oils and solvents but is fair in ketones and alcohols 280 F 138 C 40 F 40 C Hytrel Good on acids bases amines and glycols at...

Страница 8: ...LANGE 1 2 NPT AIR INLET 13 66 11 50 2 51 31 2 50 13 97 3 4 NPT AIR EXHAUST 7 00 NOTES 1 THE DIMENSIONS ON THIS DRAWING ARE FOR REFERENCE ONLY A CERTIFIED DRAWING CAN BE REQUESTED IF PHYSICAL DIMENSION...

Страница 9: ...e check valve and into the outer fluid chamber Suction side stroking also initiates the reciprocating shifting stroking or cycling action of the pump The suction diaphragm s movement is mechanically p...

Страница 10: ...perating Water in the air supply can be reduced by using a point of use air dryer Air Inlet And Priming To start the pump slightly open the air shut off valve After the pump primes the air valve can b...

Страница 11: ...oint of use air drier Clogged manifolds Clean manifolds to allow proper air flow Deadhead system pressure meets or exceeds air supply pressure Increase the inlet air pressure to the pump Pump is desig...

Страница 12: ...1 PILOT ASY DETAIL 27 26 25 28 TWO PIECE DIAPHRAGM ASY 23 25 METALLIC SEAT OPTION Torque Setting 350 in lbs 39 N m Torque Setting 200 in lbs 22 N m Torque Setting 60 in lbs 6 N m 8 9 11 19 10 12 14 23...

Страница 13: ...2 1 Muffler 530 036 000 Diaphragm Assembly Elastomers Item Qty Description Part Number Versa Rugged PTFE Two Piece Fusion 23 1 Main Shaft P31 103 P31 102 P31 103 24 2 Main Shaft Stud N A V221F N A 25...

Страница 14: ...N809 2012 Pumps and Pump Units for Liquids Common Safety Requirements to verify conformance 5 YEAR Limited Product Warranty Warren Rupp Inc Warren Rupp warrants to the original end use purchaser that...

Страница 15: ...600 F30B1SKSNTF600 F30B1SZSNTF600 Food Processing Pump Models Tranquilizer Surge Suppressors T15B1SSTSTS600 T20B1SASWTS600 T20B1SDSWTS600 T20B1SASSTS600 T20B1SDSSTS600 T20B1SASWTS600 T20B1SDSWTS600 T2...

Страница 16: ...ies U Series F Series T Series EH Series SH Series GH Series Conductive plastic pump models with integral muffler S Series PB Series Tranquilizer surge suppressors Hazardous Location Applied I M1 Ex h...

Отзывы: