background image

WARMIG-250 WARMIG-400 WARMIG-600

Description

Part No.

Part No.

Part No.

Sequence and drive card With 2/4 Track 
Function

C170203

C170203

C170203

Wire feeder D.C Motor

C2454

C2454

C2454

Solonoid Valve

C2601

C2601

C2601

Control Transformer

C140503

C140503

C140503

Digital Panel meter 0.75MVDC

C2429

Digital Panel meter 200V DC

C2430

Ampere meter (Analouge)

C2427

Volt. Metere

C2428

C2428

Primary Coil

C1108

C1107

C1111

Secondary Coil

C1115

C1114

C1118

Choke Coil

C1128

C1127

C1129

Diode Monoblock

C150703

Diode

C150401

C150502

Exhaust fan

C160403

C160403

C160403

Rotary Switch 

C2201

Rotary Switch 3 pole 5 way

C2217

C2217

Rotary Switch 3 pole 6 way

C2216

C2216

Rotary Switch

C2206

C2206

C2206

Shunt 
Power Plug Metal type Male (3 Pin)

C2411

C2411

C2411

Power Plug Metal type Female (3 Pin)

C2412

C2412

C2412

Power Plug Metal Type Male (2 Pin)

C2413

C2413

C2413

Power Plug Metal Type Female (2 Pin)

C2414

C2414

C2414

Out Put Connector

C180303

C180101

C180202

Contactor

C2302

C2303

C2303

LIST OF SPARES FOR WARMIG-MACHINES

Содержание WARMIG-400

Страница 1: ...ELDING MACHINE MODEL WARMIG 400 WARPP ENGINEERS PVT LTD B 1005 WESTERN EDGE II NEAR METRO MALL OFF WESTERN EXPRESS HIGHWAY BORIVALI E MUMBAI 400 066 Tel 91 22 28542272 73 74 Fax 28542275 E mail sales...

Страница 2: ...3 5 SAFETY 3 6 VOLTAGE SETTING CHART 4 7 FEED RATE CHART 4 8 OPERATION 5 9 FAULT FINDING 6 10 SPARE PART LIST 7 ILLUSTRATIONS 1 CONTROL WIRING INSIDE THE POWER SOURCE 1 2 CONTROLWIRING OF THE FEEDER...

Страница 3: ...st the output voltage Super Enameled Copper wirers are used for primary winding and fiber glass coated strips are used for secondary windings The coils are varnished with H Class grade varnish for dur...

Страница 4: ...card used to drive the wire feeder motor is MOSFET based and the design is rugged enough to absorb the voltage fluctuation The electronic stopping circuitry is provided for instant stopping of the wi...

Страница 5: ...NECT THE MACHINE TO THE POWER SUPPLY AND SEPARATE EARTHING TO BE PROVIDED SAFETY All safety precautions are to be taken for the safety of welders and surrounding people Some of them are listed below 1...

Страница 6: ...6 1 31 5 39 2 52 9 NOTE Voltage indicated are NO LOAD Voltages and the welding voltages will be lower than this WIRE FEED RATE CHART Wire feed rate in meters per minute as per the setting of feeder po...

Страница 7: ...g in to Torch Keep it pressed till the wire comes out the TIP of the torch 6 Connect the regulator heater combination to the CO2 cylinder 7 Release the CO2 gas 8 Now one dial of the regulator will sho...

Страница 8: ...nter connecting cable connection at both the machine end and feeder end 5 When the torch trigger is pressed the wires comes out of the torch gas starts flowing but welding do not takes place 1 Check f...

Страница 9: ......

Страница 10: ......

Страница 11: ......

Страница 12: ......

Страница 13: ...07 C1111 Secondary Coil C1115 C1114 C1118 Choke Coil C1128 C1127 C1129 Diode Monoblock C150703 Diode C150401 C150502 Exhaust fan C160403 C160403 C160403 Rotary Switch C2201 Rotary Switch 3 pole 5 way...

Страница 14: ......

Отзывы: