FAULT FINDING 

 
Sr. 
No. 

Fault 

What to check 

Machine is switched on but neither the 
mains indicator glows nor the fan is 
operating 

1)  Check for the proper three phase supply 
2)  Check the control fuse mounted on the control 
transformer of the power source 

The machine is Switched on but the 
indicator on the feeder do not glow 
and on operating the inching button 
the wire feeder 

1)  Check the three core inter connecting cable 
connection at both the machine end and feeder 
end. 
 1)  Check the glass fuse provided on the feeder  
( the glass fuse is mounted  on the panel between 
the front panel of the feeder and the control box) 

When the machine is started the wire 
start to come out of the torch 
automatically with out triggering the 
switch on the torch 

Check the NC element connected to the inching 
switch of the feeder ( If the NC contact is faulty 
the two wires connected to the this element can be 
shorted for  temporary relief) 

When the torch trigger is pressed the 
wire comes out of the torch but gas do 
not flow and the voltage do not come 

Check the three core inter connecting cable 
connection at both the machine end and feeder 
end. 

When the torch trigger is pressed the 
wires comes out of the torch , gas 
starts flowing but welding do not takes 
place 

1)

 

Check for the proper three phase 
connection 

2)

 

Set the feeder knob to zero and set the 
COARSE and FINE SWITCH to the 
maximum and press the trigger on the 
torch, then volt meter should show a 
voltage of around 55 volts in WARMIG-
400and 39 Volts in WARMIG-250. If the 
voltage is less than this check the3 phase 
supply and for proper operation of the 
contactor. 

Welding is taking place but the current 
tends to drop in between and the arc 
goes up to the TIP of the torch 

 The feed rate set is low increase the feed rate till 
you get proper and steady current 

Welding is taking place but a jerk is 
felt while welding and the torch is  
pushed away from the job 

The wire feed set is high. Reduce the wire feed 
rate till you get a steady welding current 

Each time welding is finished long 
wire comes out of the torch 

BURN-OFF time set is too high 
Blue color preset is provided on the sequence card 
(a card with two relays). Adjust this to set it right. 
NOTE: this adjustment has to be done only if it of 
utmost importance and it is causing high 
inconvenience to the welder 

 

Содержание WARMIG-400

Страница 1: ...ELDING MACHINE MODEL WARMIG 400 WARPP ENGINEERS PVT LTD B 1005 WESTERN EDGE II NEAR METRO MALL OFF WESTERN EXPRESS HIGHWAY BORIVALI E MUMBAI 400 066 Tel 91 22 28542272 73 74 Fax 28542275 E mail sales...

Страница 2: ...3 5 SAFETY 3 6 VOLTAGE SETTING CHART 4 7 FEED RATE CHART 4 8 OPERATION 5 9 FAULT FINDING 6 10 SPARE PART LIST 7 ILLUSTRATIONS 1 CONTROL WIRING INSIDE THE POWER SOURCE 1 2 CONTROLWIRING OF THE FEEDER...

Страница 3: ...st the output voltage Super Enameled Copper wirers are used for primary winding and fiber glass coated strips are used for secondary windings The coils are varnished with H Class grade varnish for dur...

Страница 4: ...card used to drive the wire feeder motor is MOSFET based and the design is rugged enough to absorb the voltage fluctuation The electronic stopping circuitry is provided for instant stopping of the wi...

Страница 5: ...NECT THE MACHINE TO THE POWER SUPPLY AND SEPARATE EARTHING TO BE PROVIDED SAFETY All safety precautions are to be taken for the safety of welders and surrounding people Some of them are listed below 1...

Страница 6: ...6 1 31 5 39 2 52 9 NOTE Voltage indicated are NO LOAD Voltages and the welding voltages will be lower than this WIRE FEED RATE CHART Wire feed rate in meters per minute as per the setting of feeder po...

Страница 7: ...g in to Torch Keep it pressed till the wire comes out the TIP of the torch 6 Connect the regulator heater combination to the CO2 cylinder 7 Release the CO2 gas 8 Now one dial of the regulator will sho...

Страница 8: ...nter connecting cable connection at both the machine end and feeder end 5 When the torch trigger is pressed the wires comes out of the torch gas starts flowing but welding do not takes place 1 Check f...

Страница 9: ......

Страница 10: ......

Страница 11: ......

Страница 12: ......

Страница 13: ...07 C1111 Secondary Coil C1115 C1114 C1118 Choke Coil C1128 C1127 C1129 Diode Monoblock C150703 Diode C150401 C150502 Exhaust fan C160403 C160403 C160403 Rotary Switch C2201 Rotary Switch 3 pole 5 way...

Страница 14: ......

Отзывы: